Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20052D018 + (12:36:36, 18 December 2024)
- ML20052D015 + (12:36:39, 18 December 2024)
- ML20052D014 + (12:36:40, 18 December 2024)
- ML20052D011 + (12:36:41, 18 December 2024)
- ML20052D008 + (12:36:44, 18 December 2024)
- IR 05000277/1982004 + (12:36:46, 18 December 2024)
- ML20052D006 + (12:36:47, 18 December 2024)
- ML20052D002 + (12:36:48, 18 December 2024)
- TAC:48122 + (12:36:49, 18 December 2024)
- ML20052D001 + (12:36:50, 18 December 2024)
- ML20052C999 + (12:36:53, 18 December 2024)
- ML20052D000 + (12:36:53, 18 December 2024)
- ML20052C996 + (12:36:56, 18 December 2024)
- ML20052C995 + (12:36:57, 18 December 2024)
- ML20052C992 + (12:36:58, 18 December 2024)
- ML20052C991 + (12:36:59, 18 December 2024)
- ML20052C985 + (12:37:02, 18 December 2024)
- ML20052C986 + (12:37:02, 18 December 2024)
- 05000316/LER-1982-027-03, /03L-0:on 820330,w/RCS in Mode 3,containment Air Particulate & Gaseous Radiation Monitoring Sys (R-11/R-12) Sample Pump Tripped on Low Flow.Apparently Caused by Wearing in or Seating of Sample Pump Carbon Vanes + (12:37:04, 18 December 2024)
- ML20052C980 + (12:37:05, 18 December 2024)
- ML20052C978 + (12:37:06, 18 December 2024)
- ML20052C976 + (12:37:07, 18 December 2024)
- ML20052C974 + (12:37:08, 18 December 2024)
- ML20052C972 + (12:37:12, 18 December 2024)
- ML20052C971 + (12:37:12, 18 December 2024)
- ML20052C968 + (12:37:13, 18 December 2024)
- 05000316/LER-1982-026-03, /03L-0:on 820401,during Return to 100% Power Following Outage,West Feed Pump Turbine Tripped Requiring Rapid Power Reduction Causing Pressurizer Pressure to Drop Below Tech Spec Requirements + (12:37:15, 18 December 2024)
- ML20052C966 + (12:37:18, 18 December 2024)
- AECM-82-149, Forwards Addl Info Re Comparison of Planned Controls for Handling Heavy Loads W/Guidelines of NUREG-0612,per NRC 801222 Request + (12:37:19, 18 December 2024)
- ML20052C961 + (12:37:21, 18 December 2024)
- ML20052C960 + (12:37:24, 18 December 2024)
- ML20052C959 + (12:37:25, 18 December 2024)
- ML20052C956 + (12:37:26, 18 December 2024)
- ML20052C957 + (12:37:26, 18 December 2024)
- ML20052C954 + (12:37:27, 18 December 2024)
- ML20052C952 + (12:37:28, 18 December 2024)
- ML20052C953 + (12:37:28, 18 December 2024)
- ML20052C951 + (12:37:29, 18 December 2024)
- ML20052C949 + (12:37:30, 18 December 2024)
- ML20052C950 + (12:37:30, 18 December 2024)
- ML20052C948 + (12:37:31, 18 December 2024)
- ML20052C947 + (12:37:32, 18 December 2024)
- ML20052C946 + (12:37:33, 18 December 2024)
- ML20052C942 + (12:37:36, 18 December 2024)
- ML20052C944 + (12:37:36, 18 December 2024)
- ML20052C940 + (12:37:37, 18 December 2024)
- 05000302/LER-1982-028-03, /03L-0:on 820330,following Reactor Trip,Discovered Source Range Instrument Indicating Below Tech Spec Limits.Caused by Failed High Voltage Power Supply.Power Supply for Instrument Replaced + (12:37:39, 18 December 2024)
- ML20052C937 + (12:37:40, 18 December 2024)
- ML20052C938 + (12:37:40, 18 December 2024)
- ML20052C932 + (12:37:42, 18 December 2024)
- 05000302/LER-1982-028, Forwards LER 82-028/03L-0 + (12:37:43, 18 December 2024)