Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20053A362 + (09:38:58, 18 December 2024)
- ML20053A361 + (09:38:59, 18 December 2024)
- ML20053A360 + (09:39:00, 18 December 2024)
- ML20053A359 + (09:39:01, 18 December 2024)
- 05000316/LER-1982-038-03, /03L-0:on 820420,steam Generator 3 Stop Valve Dump Valve MRV-232 Removed from Svc to Repair Seat Leakage, Leading to Valve in Less Conservative Configuration than Tech Spec Reqquirement.Seat Ring Replaced + (09:39:02, 18 December 2024)
- ML20053A357 + (09:39:03, 18 December 2024)
- AECM-82-209, Forwards Proposed Revision to SER,NUREG-0831,Chapter 17, Clarifying Organizational & Programmatic Policies Outlined in Util Operational QA Manual MPL-TOP-1A + (09:39:05, 18 December 2024)
- ML20053A353 + (09:39:07, 18 December 2024)
- ML20053A352 + (09:39:08, 18 December 2024)
- ML20053A350 + (09:39:09, 18 December 2024)
- ML20053A349 + (09:39:10, 18 December 2024)
- ML20053A348 + (09:39:11, 18 December 2024)
- ML20053A347 + (09:39:12, 18 December 2024)
- ML20053A346 + (09:39:14, 18 December 2024)
- 05000316/LER-1979-031, Forwards Updated LER 79-031/03X-1 & LER 82-038/03L-0 + (09:39:15, 18 December 2024)
- 1CAN058203, Application to Amend License DPR-51,revising Tech Specs to Raise Steam Line Break Instrumentation & Control Setpoints + (09:39:17, 18 December 2024)
- ML20053A339 + (09:39:23, 18 December 2024)
- 05000245/LER-1982-010-03, /03L-0:on 820413,while Performing Emergency Svc Water Sys Operational Readiness Test,Valve 1-LPC-4A Failed to Open When Emergency Svc Water Pumps Started.Caused by Excessive Play in Potentiometer.Slider Adjusted + (09:39:27, 18 December 2024)
- ML20053A337 + (09:39:28, 18 December 2024)
- 05000373/LER-1982-008-03, /03L-0:on 820428,vent Stack Recorder Read at Level Higher than Operating Conditions Estimate.Caused by Failure of Flow Transmitter.Transmitter Repaired + (09:39:30, 18 December 2024)
- ML20053A335 + (09:39:31, 18 December 2024)
- 05000272/LER-1982-027-99, During Surveillance Testing,Fire Pump 2 Did Not Start in Automatic Mode & Declared Inoperable.Caused by Damaged Flywheel.Flywheel Repaired + (09:39:33, 18 December 2024)
- 05000245/LER-1982-010, Forwards LER 82-010/03L-0.Detailed Event Analysis Encl + (09:39:36, 18 December 2024)
- ML20053A330 + (09:39:38, 18 December 2024)
- 05000267/LER-1982-015-03, /03L-0:on 820418 & 19,w/plant Operating at Power, Emergency Feedwater to Loop 2 Circulator Water Turbine Drives Were Isolated to Repair PV-21244 & PV-21244-1.Caused by Normal Wear,Resulting in Excessive Flow + (09:39:39, 18 December 2024)
- 05000373/LER-1982-008, Forwards LER 82-008/03L-0 + (09:39:41, 18 December 2024)
- ML20053A326 + (09:39:42, 18 December 2024)
- 05000272/LER-1982-027, Forwards Corrected LER 82-027/99X-0.Detailed Event Analysis Encl + (09:39:44, 18 December 2024)
- 05000267/LER-1982-015, Forwards LER 82-015/03L-0.Detailed Event Analysis Encl + (09:39:46, 18 December 2024)
- ML20053A321 + (09:39:47, 18 December 2024)
- ML20053A320 + (09:39:48, 18 December 2024)
- ML20053A317 + (09:39:50, 18 December 2024)
- ML20053A316 + (09:39:51, 18 December 2024)
- ML20053A315 + (09:39:52, 18 December 2024)
- ML20053A314 + (09:39:53, 18 December 2024)
- 05000373/LER-1982-005-03, /03L-0:on 820426,OB Control Room HVAC Emergency Makeup Train Found Inoperable.Caused by Binding Limit Switch on Damper OVCO2YB.Limit Switch Adjusted + (09:39:55, 18 December 2024)
- ML20053A312 + (09:40:02, 18 December 2024)
- 05000373/LER-1982-010-03, /03L-0:on 820428,B Fuel Pool Cooling Ventilation Exhaust Radiation Monitor Read Greater than Tech Spec Allowance.Caused by Failure of Geiger Muller Tube.Tube Replaced & Monitor Returned to Svc + (09:40:04, 18 December 2024)
- 05000373/LER-1982-007-03, /03L-0:on 820418-24,operating Personnel Used Newly Installed Vent Stack Radiation Microprocessor Rather than Monitor Ref by Surveillance.On 820424-28,no Radiation Readings Taken.Caused by Personnel Unawareness of New Sys + (09:40:14, 18 December 2024)
- ML20053A309 + (09:40:16, 18 December 2024)
- ML20053A308 + (09:40:17, 18 December 2024)
- 05000373/LER-1982-005, Forwards LER 82-005/03L-0 + (09:40:23, 18 December 2024)
- 05000373/LER-1982-010, Forwards LER 82-010/03L-0 + (09:40:32, 18 December 2024)
- ML20053A303 + (09:40:35, 18 December 2024)
- ML20053A302 + (09:40:37, 18 December 2024)
- 05000373/LER-1982-011-03, /03L-0:on 820502,continuous Sampling of Main Stack Gaseous Effluent Not Immediately Established When Bus 141Y Was Taken Down for Cleaning,Causing Monitoring Sys to Be Inoperable.Caused by Temporary Power Outage + (09:40:39, 18 December 2024)
- 05000373/LER-1982-007, Forwards LER 82-007/03L-0 + (09:40:53, 18 December 2024)
- ML20053A298 + (09:40:55, 18 December 2024)
- ML20053A296 + (09:40:56, 18 December 2024)
- ML20053A295 + (09:40:57, 18 December 2024)
- TXX-3520, Forwards Table Describing 820521 Amend 32 to FSAR + (09:40:58, 18 December 2024)