- ML20062N647 + (03:17:56, 17 December 2024)
- 05000278/LER-1993-011-02, :on 931211,terminal Block in Bottom of 4 Kv Cubicle Knocked Off Its Mount.Caused by Improper Coordination of Required TS Surveillance Requirement Shift Supervisor.Supervisor Counselled + (03:17:58, 17 December 2024)
- 05000271/LER-1993-014, :on 931009,alternate Cooling Sys Determined to Be Inoperable.Caused by Personnel Inadequately Establishing Acceptance Criteria for Insp of Cooling Tower Basin & Suction Pit.Deep Basin Drained + (03:18:00, 17 December 2024)
- ML20062N641 + (03:18:01, 17 December 2024)
- ML20062N636 + (03:18:01, 17 December 2024)
- ML20062N624 + (03:18:04, 17 December 2024)
- ML20062N607 + (03:18:05, 17 December 2024)
- ML20062N619 + (03:18:05, 17 December 2024)
- ML20062N603 + (03:18:06, 17 December 2024)
- ML20062N595 + (03:18:08, 17 December 2024)
- ML20062N590 + (03:18:09, 17 December 2024)
- ML20062N588 + (03:18:09, 17 December 2024)
- ML20062N585 + (03:18:10, 17 December 2024)
- ML20062N581 + (03:18:11, 17 December 2024)
- ML20062N579 + (03:18:12, 17 December 2024)
- ML20062N561 + (03:18:21, 17 December 2024)
- 05000315/LER-1982-057, Forwards LER 82-057/03L-0 + (03:18:22, 17 December 2024)
- ML20062N551 + (03:18:22, 17 December 2024)
- ML20062N548 + (03:18:23, 17 December 2024)
- ML20062N541 + (03:18:24, 17 December 2024)
- ML20062N545 + (03:18:24, 17 December 2024)
- ML20062N540 + (03:18:25, 17 December 2024)
- 05000315/LER-1982-056-03, /03L-0:on 820717,during Surveillance Test of Automatic Load Sequence Timing Relays,Three Relay Timers Exceeded Allowable Tolerance.Caused by Instrument Drift. Timers Adjusted.Use of New Solid State Relay Under Review + (03:18:26, 17 December 2024)
- ML20062N524 + (03:18:27, 17 December 2024)
- ML20062N514 + (03:18:28, 17 December 2024)
- ML20062N521 + (03:18:28, 17 December 2024)
- 05000315/LER-1982-056, Forwards LER 82-056/03L-0 + (03:18:30, 17 December 2024)
- ML20062N511 + (03:18:30, 17 December 2024)
- ML20062N506 + (03:18:31, 17 December 2024)
- ML20062N505 + (03:18:32, 17 December 2024)
- ML20062N476 + (03:18:34, 17 December 2024)
- ML20062N473 + (03:18:36, 17 December 2024)
- ML20062N467 + (03:18:37, 17 December 2024)
- ML20062N463 + (03:18:39, 17 December 2024)
- 05000317/LER-1982-041-03, /03L-0:on 820713,channel a High Power,Thermal Margin/Low Pressure & Axial Shape Index Trip Units Bypassed to Allow Failing Hot Leg Temp Element Signal to Be Removed from Reactor Protective Sys.Caused by Changing Temp Element + (03:18:40, 17 December 2024)
- 05000317/LER-1982-041, Forwards LER 82-041/03L-0 + (03:18:41, 17 December 2024)
- 05000305/LER-1982-025-03, /03L-0:on 820716,during Document Review,Waste Disposal Liquid Effluent Monitor Found Indicating Low.Caused by Weak Detection Tube on Monitor.Tube Replaced & Detector Recalibr + (03:18:43, 17 December 2024)
- ML20062N427 + (03:18:44, 17 December 2024)
- ML20062N432 + (03:18:44, 17 December 2024)
- ML20062N421 + (03:18:45, 17 December 2024)
- 05000305/LER-1982-024-03, /03L-0:on 820716,while at Full Power,Overpower Delta T Channel 3 Rod Stop Alarm Observed Cycling in & Out. Caused by Malfunction of Tavg Signal Conditioner Causing Channel to Drift.Spare Signal Box Installed & Calibr + (03:18:47, 17 December 2024)
- LIC-93-0299, Forwards Application for Amend to License DPR-40,revising TS Surveillance Test Frequency from Monthly to Quarterly for Several Channel Functional Tests for RPS & ESF I&Cs,Per GL 93-05,based on NRC Approval of TR CEN-327-A & Tr,Suppl 1 + (03:18:48, 17 December 2024)
- ML20062N417 + (03:18:48, 17 December 2024)
- ML20062N412 + (03:18:49, 17 December 2024)
- ML20062N404 + (03:18:55, 17 December 2024)
- B14716, Requests Relief from ASME Boiler & Pressure Vessel Code Section XI Requirements,Per GL 90-05.Description of Actions Taken by Util to Repair Leak in SWS Piping Line 3SWP-010-028-3 as Alternative to IWA-4000/70005 Repair + (03:18:56, 17 December 2024)
- ML20062N388 + (03:18:56, 17 December 2024)
- JAFP-82-0543, Responds to NRC Re Violations Noted in IE Insp Rept 50-333/82-01.Corrective Actions:Valves 250C & BAS-4 Repositioned to Agree W/Lineup List & Procedures Reviewed for Control of Plant Status + (03:18:58, 17 December 2024)
- ML20062N378 + (03:18:58, 17 December 2024)
- JAFP-82-0850, Responds to NRC Re Violations Noted in IE Insp Rept 50-333/82-06.Corrective Actions:Operator Stationed at Portable Monitor to Continuously Monitor Containment Atmosphere + (03:19:02, 17 December 2024)
- ML20062N361 + (03:19:02, 17 December 2024)
- ML20062N347 + (03:19:03, 17 December 2024)