- ML20074A541 + (08:11:56, 15 December 2024)
- ML20074A542 + (08:11:56, 15 December 2024)
- ML20074A534 + (08:11:57, 15 December 2024)
- ML20074A533 + (08:11:57, 15 December 2024)
- ML20074A532 + (08:11:58, 15 December 2024)
- 05000255/LER-1983-026-01, /01T-0:on 830428,sample from T-82D (Safety Tank D) Showed Boron Concentration Below Tech Spec Limit.Caused by Boron Dilution Due to Minor Leakage Past Loop Check Valve. Primary Coolant Leak Rate Monitored + (08:11:59, 15 December 2024)
- ML20074A530 + (08:12:00, 15 December 2024)
- 05000260/LER-1983-017-03, /03L-0:on 830409,hydrogen Analyzer B,H2AN-76-104 Declared Inoperable Due to Receipt of loss-of-flow Light 76-88.Caused by Moisture Collecting in Sample Lines.Lines Blown Down & Dried.Moisture Collection Devices to Be Added + (08:12:02, 15 December 2024)
- 05000255/LER-1983-026, Forwards LER 83-026/01T-0 + (08:12:03, 15 December 2024)
- ML20074A520 + (08:12:03, 15 December 2024)
- 05000281/LER-1983-018-03, /03L-0:on 830406,at 100% Power,Control Rod B-6 Dropped to Fully Inserted Position Causing Quadrant Power Tilt or Turbine Runback.Cause Unknown.Fuses & Other Components Operable.Control Rod Withdrawn + (08:12:05, 15 December 2024)
- ML20074A518 + (08:12:06, 15 December 2024)
- ML20074A517 + (08:12:06, 15 December 2024)
- 05000260/LER-1983-017, Forwards LER 83-017/03L-0 + (08:12:07, 15 December 2024)
- ML20074A515 + (08:12:07, 15 December 2024)
- 05000281/LER-1983-017-03, /03L-0:on 830408,at 100% Power,Amp Readings for Heat Tracing Panels 8 & 9,circuit 20B Discovered Below Acceptable Limits.Caused by Excessive Heat.Defective Heat Tracing Replaced.Design Changes Implemented + (08:12:09, 15 December 2024)
- ML20074A508 + (08:12:10, 15 December 2024)
- ML20074A507 + (08:12:10, 15 December 2024)
- ML20074A504 + (08:12:11, 15 December 2024)
- ML20074A505 + (08:12:11, 15 December 2024)
- ML20074A503 + (08:12:12, 15 December 2024)
- ML20074A502 + (08:12:13, 15 December 2024)
- ML20074A499 + (08:12:13, 15 December 2024)
- BSEP-83-1421, Ro:On 830404,fire Barrier Limiting Conditions for Operation Initiated on Penetration Seal CB-2-301 of Fire Door 221. Caused by Need to Allow Ambient Air Circulation Due to Inoperability of Computer Room Air Conditioner + (08:12:14, 15 December 2024)
- ML20074A497 + (08:12:14, 15 December 2024)
- ML20074A492 + (08:12:15, 15 December 2024)
- GO2-83-389, Interim Deficiency Repts on Condition 221 Re Namco EA-180 & EA-740 Limit Switches & Condition 226 Re 125-volt Dc Motor Operator Connected to 250-volt Dc Power Source.Next Rept by 830726 + (08:12:16, 15 December 2024)
- ML20074A489 + (08:12:16, 15 December 2024)
- ML20074A487 + (08:12:17, 15 December 2024)
- 05000315/LER-1983-024-03, /03L-0:on 830317,during Normal Operation,Fire Door 517 from Contractor Access Control to Auxiliary Bldg Would Not Close Properly.Caused by Extended Dead Bolt Lock Preventing Doors from Closing.Dead Bolt Removed + (08:12:18, 15 December 2024)
- ML20074A481 + (08:12:19, 15 December 2024)
- 05000315/LER-1983-024, Forwards LER 83-024/03L-0 + (08:12:20, 15 December 2024)
- ML20074A478 + (08:12:20, 15 December 2024)
- 05000346/LER-1983-012-01, Operating Practice of Requiring One ECCS Room Cooler to Be Valved Into Svc in Each ECCS Room Less Conservative than Updated FSAR Assumptions. Caused by Lack of Procedural Control.Fsar Reviewed + (08:12:22, 15 December 2024)
- ML20074A476 + (08:12:23, 15 December 2024)
- 05000346/LER-1983-012, Forwards Revised LER 83-012/01X-2 + (08:12:24, 15 December 2024)
- ML20074A473 + (08:12:24, 15 December 2024)
- 05000259/LER-1983-021-01, /01T-0:on 830424,130 Fuel Bundles Unloaded from Core Into high-density Spent Fuel Storage Rack (Hdsfsr) Did Not Have Required post-installation Boron Test.Caused by Personnel Failure to Verify Hdsfsr Acceptability + (08:12:26, 15 December 2024)
- ML20074A470 + (08:12:27, 15 December 2024)
- ML20074A471 + (08:12:27, 15 December 2024)
- 05000259/LER-1983-021, Forwards LER 83-021/01T-0 + (08:12:28, 15 December 2024)
- ML20074A469 + (08:12:28, 15 December 2024)
- ML20074A465 + (08:12:29, 15 December 2024)
- ML20074A464 + (08:12:29, 15 December 2024)
- ML20074A460 + (08:12:30, 15 December 2024)
- ML20074A463 + (08:12:30, 15 December 2024)
- ML20074A458 + (08:12:31, 15 December 2024)
- ML20074A457 + (08:12:32, 15 December 2024)
- ML20074A456 + (08:12:32, 15 December 2024)
- ML20074A455 + (08:12:33, 15 December 2024)
- ML20074A454 + (08:12:33, 15 December 2024)
- ML20074A453 + (08:12:34, 15 December 2024)