- 05000334/LER-1983-008, Forwards Updated LER 83-008/03X-1 + (03:53:17, 15 December 2024)
- 05000289/LER-1983-011-01, /01T-0:on 830415,while in long-term Shutdown DH-P1A Shaft Bearings Failed,Making Pump Inoperable.Caused by Improperly Authorized Mod to Component & Inadequate Mod Set Up.Pump Repaired.Maint Job Tickets Reviewed + (03:53:19, 15 December 2024)
- 05000293/LER-1983-015-03, /03L-0:on 830331,standby Gas Treatment Sys Train Opened W/O Proving Operability of Redundant Train.Caused by Miscommunication Between Insp Crew & Control Room.Need for Proper Communications Emphasized + (03:53:21, 15 December 2024)
- 05000278/LER-1983-011, Forwards LER 83-011/01T-0.Detailed Event Analysis Submitted + (03:53:22, 15 December 2024)
- RBG-16-320, Forwards Responses to Open Items Identified in Draft SER & Discussed W/Chemical Engineering Branch in Bethesda,Md on 830525.Encls 3-10 Will Be Included in Next FSAR Amend + (03:53:23, 15 December 2024)
- ML20079Q002 + (03:53:24, 15 December 2024)
- 05000339/LER-1983-023-03, /03L-0:on 830414,RHR Flow Temporarily Lost When One of Two in-series RHR Suction Valves Closed.Caused by Open Input Breaker.Breaker Reclosed,Vital Bus Restored,Rhr Suction Valve Reopened & Flow Restored + (03:53:25, 15 December 2024)
- ML20079P996 + (03:53:26, 15 December 2024)
- 05000270/LER-1983-006-03, /03L-0:on 830401,after Pumping Down Reactor Bldg Normal Sump Level,Valve 2LWD-1 Found Cycling Open & Shut Since Work Completion.Caused by Component Malfunction.Valve Locked Shut.Valve Will Be Disassembled for Repair + (03:53:28, 15 December 2024)
- 05000293/LER-1983-015, Forwards LER 83-015/03L-0 + (03:53:29, 15 December 2024)
- 05000289/LER-1983-011, Forwards LER 83-011/01T-0 + (03:53:30, 15 December 2024)
- ML20079P985 + (03:53:30, 15 December 2024)
- ML20079P981 + (03:53:31, 15 December 2024)
- ML20079P978 + (03:53:32, 15 December 2024)
- ML20079P973 + (03:53:32, 15 December 2024)
- 05000339/LER-1983-023, Forwards LER 83-023/03L-0 + (03:53:33, 15 December 2024)
- ML20079P968 + (03:53:34, 15 December 2024)
- 05000327/LER-1983-054-03, /03L-0:on 830406,while Performing Special Test SQ-STEAR-INST-83-3,containment Isolation Valve 1-FCV-1-182 Failed to Open.Valve Repaired But Failed Again 2 Days Later. Caused by Excessive Wear.Parts Replaced + (03:53:35, 15 December 2024)
- 05000244/LER-1983-014-03, /03L-0:on 830329,during Refueling Calibr,Certain Steam Generator Level Transmitter Outputs Shifted Low by 2 to 2.5% of Span.Caused by Instrument Drift.Transmitters Recalibr + (03:53:37, 15 December 2024)
- ML20079P960 + (03:53:38, 15 December 2024)
- 05000315/LER-1983-127-03, /03L-0: on 831223,Fire Door 519 Found Partially Open.Caused by Personnel Attempting to Use Door.Positive Lock Mechanism Fabricated & Installed + (03:53:40, 15 December 2024)
- ML20079P955 + (03:53:41, 15 December 2024)
- 05000327/LER-1983-054, Forwards LER 83-054/03L-0 + (03:53:42, 15 December 2024)
- 05000270/LER-1983-006, Forwards LER 83-006/03L-0.Detailed Event Analysis Encl + (03:53:43, 15 December 2024)
- ML20079P942 + (03:53:43, 15 December 2024)
- 05000244/LER-1983-014, Forwards LER 83-014/03L-0 + (03:53:44, 15 December 2024)
- ML20079P936 + (03:53:45, 15 December 2024)
- 05000315/LER-1983-126-03, /03L-0:on 831230,RCS Average Temp DNB Parameter of 570.5 F Exceeded for Two Short Periods of Time.Caused by Operator Holding Turbine Control Valve Closed to Gather Turbine Control Data.Alarm Setpoint Lowered + (03:53:47, 15 December 2024)
- ML20079P934 + (03:53:48, 15 December 2024)
- 05000387/LER-1983-052-03, /03L-0:on 830325,during Surveillance Test,Creoass Train a Tripped.Caused by Fan Belts Coming Off Fan Pulley. Belts Replaced & Bearings & Fan Pulley Realigned + (03:53:49, 15 December 2024)
- ML20079P930 + (03:53:50, 15 December 2024)
- 05000259/LER-1984-002-05, :on 840103,setpoint Value of Pressure Switches PS-64-57A-D Found Above Tech Spec 3.2.B. Limits.Caused by Static O-ring Model 12N-AA4 Setpoint Drift.Switches Recalibr.Surveillance Test Revised + (03:53:52, 15 December 2024)
- ML20079P927 + (03:53:53, 15 December 2024)
- 05000387/LER-1983-052, Forwards LER 83-052/03L-0 + (03:53:54, 15 December 2024)
- ML20079P921 + (03:53:55, 15 December 2024)
- ML20079P922 + (03:53:55, 15 December 2024)
- 05000366/LER-1983-140-03, /03L-0:on 831225,low Nitrogen Pressure Alarm Received on Control Rod Scram Accumulators 2C11-18-43 & 2C11-26-43.Cause Unknown.Accumulators Serviced W/Nitrogen & Returned to Svc + (03:53:57, 15 December 2024)
- ML20079P919 + (03:53:59, 15 December 2024)
- ML20079P918 + (03:53:59, 15 December 2024)
- 05000366/LER-1983-143-03, /03L-0:on 831225,plant Svc Water Valve 2P41-F316C Isolated,Stopping Flow to Turbine Bldg.Caused by Ice in Differential Pressure Cell of Differential Pressure Switch. Ice Thawed & Circuit Breaker Turned on + (03:54:01, 15 December 2024)
- ML20079P916 + (03:54:02, 15 December 2024)
- ML20079P915 + (03:54:03, 15 December 2024)
- ML20079P914 + (03:54:03, 15 December 2024)
- ML20079P911 + (03:54:04, 15 December 2024)
- ML20079P912 + (03:54:04, 15 December 2024)
- ML20079P910 + (03:54:05, 15 December 2024)
- ML20079P908 + (03:54:06, 15 December 2024)
- 05000321/LER-1983-126-03, /03L-0:on 831229,during Performance of HPCI Steam Line Pressure Instrument FTC Procedure,Hpci A,B,C & D Switches Actuated Below Requirements.Caused by Setpoint Drift.Switches Recalibr + (03:54:07, 15 December 2024)
- ML20079P906 + (03:54:08, 15 December 2024)
- 05000321/LER-1983-122-03, /03L-0:on 831228,during HPCI Quick Start Procedure HNP-1-3316,HPCI Had Erratic Response & Was Tripped.Caused by Failed Ramp Generator Signal Convertor Unit.Convertor Replaced + (03:54:10, 15 December 2024)
- ML20079P899 + (03:54:11, 15 December 2024)