Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20084A399 + (10:03:14, 14 December 2024)
- 05000244/LER-1975-012-03, /03L:on 751214,pinhole Noted in 1/2-inch Socket Weld on Charging Pump B Discharge Drain Line.Caused by Faulty Weld.Affected Drain Piping Section Removed & Refabricated W/New Piping + (10:03:15, 14 December 2024)
- ML20084A390 + (10:03:17, 14 December 2024)
- ML20084A394 + (10:03:17, 14 December 2024)
- ML20084A386 + (10:03:21, 14 December 2024)
- ML20084A351 + (10:03:22, 14 December 2024)
- ML20084A381 + (10:03:22, 14 December 2024)
- ML20084A348 + (10:03:23, 14 December 2024)
- ML20084A335 + (10:03:24, 14 December 2024)
- ML20084A333 + (10:03:25, 14 December 2024)
- 05000237/LER-1976-063-03, /03L-0:on 761003,stack Gas Sample Pump Flow Appeared Abnormally Low.Caused by Carbon Impeller Vane Products Collected in Cavity & Filter.Pump & Filter Replaced + (10:03:27, 14 December 2024)
- 05000244/LER-1976-001-03, /03L:on 760111,during Surveillance Test Prior to Heatup,Cv Supply & Exhaust Valves Leaked Excessively. Possibly Caused by Low Ambient Temp During Shutdown. Investigation for Replacement Seat Matl Begun + (10:03:29, 14 December 2024)
- ML20084A319 + (10:03:30, 14 December 2024)
- ML20084A311 + (10:03:31, 14 December 2024)
- ML20084A318 + (10:03:31, 14 December 2024)
- ML20084A310 + (10:03:32, 14 December 2024)
- ML20084A307 + (10:03:33, 14 December 2024)
- ML20084A302 + (10:03:34, 14 December 2024)
- ML20084A300 + (10:03:35, 14 December 2024)
- ML20084A296 + (10:03:35, 14 December 2024)
- ML20084A294 + (10:03:36, 14 December 2024)
- 05000244/LER-1976-002-03, /03L:on 760112,operator Noticed Component Cooling Pump B Noisy.Caused by Failure of Coupling Bolts.Coupling Repaired & Motor Realigned + (10:03:38, 14 December 2024)
- 05000237/LER-1976-025-03, /03L-0:on 760413,during Fuel Loading,All Personnel Not Evacuated from 613 Ft Level for Control Rod Exercising as Required.Caused by Violation of Existing Station Procedures.Procedures re-emphasized + (10:03:40, 14 December 2024)
- 05000237/LER-1976-064-03, /03L-0:on 761029,during Surveillance Test,Diesel Generator Failed to Start Twice.Caused by Malfunctioning Shutdown Solenoid on Diesel Governor.Solenoid Readjusted + (10:03:41, 14 December 2024)
- ML20084A285 + (10:03:42, 14 December 2024)
- ML20084A284 + (10:03:43, 14 December 2024)
- ML20084A276 + (10:03:44, 14 December 2024)
- ML20084A273 + (10:03:44, 14 December 2024)
- ML20084A268 + (10:03:48, 14 December 2024)
- ML20084A269 + (10:03:47, 14 December 2024)
- ML20084A262 + (10:03:49, 14 December 2024)
- ML20084A266 + (10:03:48, 14 December 2024)
- ML20084A255 + (10:03:50, 14 December 2024)
- ML20084A261 + (10:03:49, 14 December 2024)
- ML20084A253 + (10:03:54, 14 December 2024)
- ML20084A245 + (10:03:59, 14 December 2024)
- ML20084A238 + (10:04:00, 14 December 2024)
- ML20084A233 + (10:04:01, 14 December 2024)
- ML20084A252 + (10:03:54, 14 December 2024)
- ML20084A232 + (10:04:01, 14 December 2024)
- ML20084A227 + (10:04:02, 14 December 2024)
- ML20084A215 + (10:04:03, 14 December 2024)
- ML20084A207 + (10:04:05, 14 December 2024)
- ML20084A218 + (10:04:02, 14 December 2024)
- ML20084A200 + (10:04:06, 14 December 2024)
- ML20084A194 + (10:04:07, 14 December 2024)
- ML20084A181 + (10:04:08, 14 December 2024)
- ML20084A188 + (10:04:07, 14 December 2024)
- ML20084A175 + (10:04:11, 14 December 2024)
- ML20084A170 + (10:04:14, 14 December 2024)
- ML20084A166 + (10:04:14, 14 December 2024)