- ML20090E464 + (18:21:12, 13 December 2024)
- ML20090E458 + (18:21:13, 13 December 2024)
- ML20090E463 + (18:21:13, 13 December 2024)
- ML20090E456 + (18:21:14, 13 December 2024)
- ML20090E455 + (18:21:15, 13 December 2024)
- 05000362/LER-1984-026-01, :on 840612,containment Purge Isolation Sys Actuated Following Installation of Iodine Channel Module W/Defective Alarm Defeat Button.Operability of Alarm Defeat Function to Be Verified + (18:21:20, 13 December 2024)
- ML20090E452 + (18:21:21, 13 December 2024)
- 05000220/LER-1984-010, :on 840608,reactor Protection Sys Channel 4 Power Supply Bus Experienced Momentary Power Loss Causing Condenser vacuum-MSIV Closure Scram Bypass Relays to Deenergize + (18:21:23, 13 December 2024)
- ML20090E447 + (18:21:24, 13 December 2024)
- RBG-36-562, Annual Operations Rept for 1991 + (18:21:25, 13 December 2024)
- 05000373/LER-1984-031, :on 840615,reactor Water Cleanup Sys Isolated Due to High Pump Room Differential Temp.Caused by Normal Ventilation Shut Down & Operation of Containment Vent & Purge + (18:21:27, 13 December 2024)
- 05000237/LER-1950-237, Updated LER 50-237/75-048:on 751007,through-wall Crack Found in Drywell/Torus Nitrogen Purge Line 1604-18.Addl Mods, Including Temp Controlled Isolation Valve Installation, Delayed Until Proposal Review + (18:21:28, 13 December 2024)
- ML20090E438 + (18:21:28, 13 December 2024)
- ML20090E437 + (18:21:29, 13 December 2024)
- ML20090E432 + (18:21:30, 13 December 2024)
- ML20090E435 + (18:21:30, 13 December 2024)
- 05000237/LER-1950-237-76, /76-001:on 760101,oscillograph Alarms Received on 138-kV Yard.Bus Section 1-2 Oil Circuit Breaker Bus 1 Disconnect Arced & Glowed.Caused by Loose Connector on Cable Between Ocb & Bus 1 Disconnect on C Phase + (18:21:32, 13 December 2024)
- ML20090E429 + (18:21:33, 13 December 2024)
- ML20090E418 + (18:21:37, 13 December 2024)
- ML20090E410 + (18:21:42, 13 December 2024)
- ML20090E404 + (18:21:43, 13 December 2024)
- ML20090E389 + (18:21:46, 13 December 2024)
- ML20090E377 + (18:21:47, 13 December 2024)
- ML20090E375 + (18:21:48, 13 December 2024)
- 05000286/LER-1984-009-01, :on 840616,reactor Trip Initiated on Low Level in Steam Generator 33.Caused by Main Feedwater Regulating Valve Inadvertent Closure,Due to Failure of Valve Operator Yoke + (18:21:50, 13 December 2024)
- 1CAN039201, Responds to NRC Inquiries Re Specific ATWS Analyses. Initial Analyses Provided to NRC in Topical Repts BAW-10099 & BAW-1610.Generic Analyses Used Auxiliary Feedwater Flow Rate of 780 Gpm Per Pump + (18:21:51, 13 December 2024)
- 05000361/LER-1984-029, :on 840614,breaker 3BO417 Inadvertently Tripped,Deenergizing Load Ctr Bq.Caused by Personnel Error in Tripping Wrong Breaker During Charging of Pump Power Supply.Operator Counseled + (18:21:54, 13 December 2024)
- 05000335/LER-1984-004, :on 840613,surveillance Performed on Both Shield Bldg Exhaust Fan Dampers Where Flow Less than Required 6,000 CFM on Each Train.Caused by Dampers Slightly Out of Adjustment.Dampers Adjusted + (18:21:57, 13 December 2024)
- ML20090E357 + (18:21:58, 13 December 2024)
- ML20090E355 + (18:21:59, 13 December 2024)
- ML20090E350 + (18:22:00, 13 December 2024)
- PLA-2230, Final Deficiency Rept Re Electrical Separation Inside Multiple Div Junction & Pull Boxes.Initially Reported on 830721.Drawings Revised to Clarify &/Or Define Sparation Requirements for Use W/Junction & Pull Boxes + (18:22:01, 13 December 2024)
- ML20090E346 + (18:22:02, 13 December 2024)
- ML20090E345 + (18:22:03, 13 December 2024)
- ML20090E329 + (18:22:09, 13 December 2024)
- HL-2075, Forwards Response to NRC 901218 Request for Addl Info Re 900110 Application for Amends to Licenses DPR-57 & NPF-5, Changing TS to Revise Testing Requirements on Emergency Diesel Generators + (18:22:13, 13 December 2024)
- ML20090E321 + (18:22:14, 13 December 2024)
- ML20090E313 + (18:22:16, 13 December 2024)
- ML20090E312 + (18:22:17, 13 December 2024)
- ML20090E307 + (18:22:18, 13 December 2024)
- ML20090E306 + (18:22:18, 13 December 2024)
- ML20090E305 + (18:22:19, 13 December 2024)
- ML20090E301 + (18:22:20, 13 December 2024)
- 05000374/LER-1984-030-01, :on 840615,HPCS Declared Inoperable as Result of HPCS Discharge Relief Valve 2E22-F035 Internal Bellows Seal Failure.Caused by Hydraulic Force on Seal.Valve Repaired & Tested Operational + (18:22:22, 13 December 2024)
- 05000362/LER-1984-024-01, :on 840611,spurious Penalty Factor from Control Element Assembly Calculator 1 Caused All Four Core Protection Calculators to Generate Low DNBR Trip Signals. Caused by Hardware Failure.Boards Replaced + (18:22:24, 13 December 2024)
- 05000373/LER-1984-036, :on 840614,door 444 to Reactor Water Cleanup Hold Pump Room Found Closed But Not Latched.Caused by Electrical Strike Mechanism Sticking in Open Position. Mechanism Lubricated + (18:22:26, 13 December 2024)
- ML20090E293 + (18:22:27, 13 December 2024)
- ML20090E291 + (18:22:28, 13 December 2024)
- 05000254/LER-1992-003-03, :on 920206,Unit 1 HPCI Suction Lube Oil Pressure Relief Line Pipe Hanger Found Outside FSAR Compliance.Cause Unknown.Minor Design Change Initiated to Correct Pipe Hanger Configuration + (18:22:30, 13 December 2024)
- ML20090E288 + (18:22:31, 13 December 2024)
- 05000298/LER-1984-008, :on 840609,discharge of Liquid Radioactive Effluent Occurred W/Discharge Monitor Outlet Valve Shut. Caused by Personnel Error.Procedures Revised to Prevent Recurrence + (18:22:38, 13 December 2024)