List of results
- 05000250/LER-1976-003-03, /03L:on 760519,output 1 of Pressurizer Level Comparator LC-459A Tripped at 4.685 Volts Instead of 4.680 Volts.Caused by Setpoint Drift.Trip Setpoint Reset to Conservative Value + (18:20:15, 13 December 2024)
- 05000250/LER-1976-004-01, /01T:on 760611,boron Concentration of Injection Tank Below 20,000 Ppm Limit.Caused by Recirculation W/Low Concentration of Boric Acid Storage Tank B.Shutdown Initiated + (18:20:17, 13 December 2024)
- L-76-300, Notifies That Westinghouse Informed Util That Recent Developments Have Affected Results of Certain Safety Analyses for Westinghouse Plants.Evaluation of Developments Continuing + (18:20:18, 13 December 2024)
- ML20090E601 + (18:20:19, 13 December 2024)
- ML20090E598 + (18:20:20, 13 December 2024)
- 05000250/LER-1976-005-01, /01T:on 760805,Westinghouse Informed of New Development on Results of Safety Analysis.Caused by Increase of Temp of Fluid in Upper Head & Increased Rod Bow Penalty + (18:20:21, 13 December 2024)
- 05000250/LER-1976-006-01, /01T:on 760909,closing Springs in Diesel Generator 3A Circuit Breaker Not in Charged Position.Caused by Worn Nylon Bushing Between Closing Spring Drive Motor & Linkage to Ratchet Wheel + (18:20:23, 13 December 2024)
- 05000251/LER-1976-007-01, /01T:on 761002,diesel Generator a Engine Cooling Water Tank Level Found Low.Caused by Sample Valve Not Being Fully Closed After 761001 Water Sample.Valve Closed & Water Added + (18:20:26, 13 December 2024)
- 05000250/LER-1976-008-01, /01T:on 761006,boron Concentration of Injection Tank Below 20,000 Ppm Limit.Cause Undetermined.Shutdown Initiated + (18:20:28, 13 December 2024)
- 05000250/LER-1976-009-03, /03L:on 761015,charging Pump 3B Removed from Svc Because of Damaged Rod Bearings.Caused by Insufficient Lubrication of Bearings.Pump Casing of Pump 3B Installed on Pump 3A & Pump 3A Returned to Svc + (18:20:30, 13 December 2024)
- ML20090E585 + (18:20:33, 13 December 2024)
- ML20090E584 + (18:20:33, 13 December 2024)
- ML20090E583 + (18:20:34, 13 December 2024)
- 05000250/LER-1976-010-03, /03L:on 761125,trip Setpoint of Steam Flow Comparator FC-3-484 Found to Be Nonconservative.Caused by Failure of Two Filter Capacitors on Printed Circuit Board. Capacitors to Be Replaced + (18:20:36, 13 December 2024)
- ML20090E580 + (18:20:37, 13 December 2024)
- 05000251/LER-1976-003-01, /01T:on 760517,tube Support Plate Section of Steam Generator 4C Discovered to Be Cracked.Cause Under Investigation.Manufacturer Evaluating Occurence + (18:20:38, 13 December 2024)
- ML20090E573 + (18:20:39, 13 December 2024)
- ML20090E568 + (18:20:40, 13 December 2024)
- 05000251/LER-1976-004-01, /01T:on 760611,boron Concentration of Injection Tank & Two of Three Storage Tanks Below 20,000 Ppm Limit. Caused by in-leakage from Reactor Water Storage.Shutdown Initiated + (18:20:42, 13 December 2024)
- ML20090E562 + (18:20:43, 13 December 2024)
- ML20090E565 + (18:20:43, 13 December 2024)
- ML20090E560 + (18:20:44, 13 December 2024)
- 05000251/LER-1976-005-01, /01T:on 760612,boron Concentration of Boron Injection Tank & B Boric Acid Storage Tank Below 20,000 Ppm.Caused by in-leakage from Refueling Water Storage Tank. Shutdown Initiated + (18:20:46, 13 December 2024)
- ML20090E553 + (18:20:47, 13 December 2024)
- ML20090E552 + (18:20:47, 13 December 2024)
- 05000251/LER-1976-006-03, /03L:on 760726,generator 4 Tripped by Lockout Action.Caused by Switch Not Making Proper Contact Preventing Breaker from Closing.Breaker Lowered & Raised to Establish Contact + (18:20:49, 13 December 2024)
- ML20090E547 + (18:20:50, 13 December 2024)
- 05000250/LER-1976-007-01, /01T:on 760805,heat Flux Hot Channel Factor & Enthalpy Rise Hot Channel Factor Allowable Max Reduced. Caused by Increased Limit for Upper Head Fluid & Rod Bow Penalty + (18:20:52, 13 December 2024)
- ML20090E533 + (18:20:53, 13 December 2024)
- ML20090E538 + (18:20:53, 13 December 2024)
- ML20090E514 + (18:20:54, 13 December 2024)
- ML20090E502 + (18:20:55, 13 December 2024)
- PY-CEI-NRR-1387, Requests Exemption from Requirements of 10CFR70.24, Criticality Accident Requirements. Attachment 1 Contains Discussion of Basis for Reinstating Exemption + (18:20:55, 13 December 2024)
- ML20090E500 + (18:20:56, 13 December 2024)
- ML20090E499 + (18:20:57, 13 December 2024)
- ML20090E497 + (18:20:58, 13 December 2024)
- ML20090E495 + (18:20:58, 13 December 2024)
- ML20090E491 + (18:20:59, 13 December 2024)
- ML20090E492 + (18:20:59, 13 December 2024)
- ML20090E490 + (18:21:02, 13 December 2024)
- ML20090E483 + (18:21:04, 13 December 2024)
- ML20090E486 + (18:21:04, 13 December 2024)
- ML20090E482 + (18:21:05, 13 December 2024)
- ML20090E481 + (18:21:05, 13 December 2024)
- ML20090E478 + (18:21:06, 13 December 2024)
- 05000362/LER-1984-027-01, :on 840612,daily Containment Particulate & Iodine Samples Not Taken Following Reactor Trip.Caused by Chemistry Technician Oversight.Memo Issued + (18:21:08, 13 December 2024)
- ML20090E475 + (18:21:09, 13 December 2024)
- ML20090E473 + (18:21:09, 13 December 2024)
- ML20090E472 + (18:21:10, 13 December 2024)
- ML20090E470 + (18:21:11, 13 December 2024)
- ML20090E467 + (18:21:11, 13 December 2024)