$5h SHAw, PITTMAN, PoTTs & TROWBRIDGE A DARTNEnsMer or pnOFEss*CNAL CORpONATiONsl[

1800 M STREET. N. W.

WASHINGTON, D. C. 20036 (aca) eaa-ioco QQ,,

mausAv O. pO,ns. p C CH A =tt s a.. TE = m a.

  • C

,,,,c,,,

t< vaa? Lpn

.De win TM.E N oEOaot r AL e a,o v. J * *

  • E NotuN A

.M. T E sTEpM

.Mun L E -. p C.

OmoE r. T Ow.A.N. Dot, e c.

Ja=E s. Ma e nO*N.,

Op N C.

Davio J CvNAM stAm Ev = e uN. p c J ACm A. MonN* ON LE sue m. so.nno svE pMEN O. p ns, a c o :=*tO CMA O,Orr. p C.

ma DAL..mELL PC

,E ' E CO,, E,,

in tovest A =*THE.s v'ao'N'A s auTLEOct u T'LL'OTM,BosTweCn.PC.

post er E. Z AHLE R p C.

  • M 8 Q.

s E Te,* M. MO,COGas m A TM E min E. mO.M E E m p C OEussa a a'Do 4,4, y (202) eza ices & e22 use i=

M ANtON.

  • C.

=Ost.T LuCA s. s.

  • C.

sME t A o MA g

pEmA ev N

J.

=Os N

+ E Oao E = =Oa E as. J a. p C.

STEVE N.

f sTE

  • E a* = ME
  • ANN C.

et sANUWA E, h's4 a.

IMEO A LiTTLE, D C.

CAv80 w RumE N STEIN. P C MENNEYMJ MauTwAN JO**N e mM,NgtANOER p C.

M ATI A5 F. T mavit sO-OeAZ. P C.

DaveO L A.Cm L*RENCE uiLLER E'L IEN L 8 L RvCE w CMumCM*LL P C.

viCTomeA J PE mm*Ns. P C.

RAn'FAs oCO rnEOgn mLE,N

  • AwEL A M AN esON LA ut A. NeCMOLsON JR p C.

JOM N *e O NE sLL. JR sTEvf 4 a p'TLEn ALEMANDER O. Tow ASZC2Um E psTiE N. p C. -. P C-(202)8224072 miCMano J P A mmiNO Ma m. TIN O meALL. p C JAv A EnmEv J a. Gine s "N #ENCE W J AY E. seteg no, o c JErrgavL.VastpN,PC.

ROste? C BCEMu

  • Q*[,E ",

COMEN ELLEN a rmEDEL

,e A04GE v ALLEN. Jg. p C.3 mSAmA M mossOTTt, P C J ACm McmAv. p C ELisasETH M *ENOLETON Mamet N DOLAND*

,g,g, g' A g

F' #EO OmasNE n.

  • C.

u.CMAEL s*

E N SME nsu' gen M Ammy M. GL As sp>EGEL TELEn TMOM AS C MILL k mENLT wEgstE4. D C.

OM AS M McConwiCm DIANE E.summLEv*

ELL,TA a r,NmELSTErh le4TMAN,gt p gag g o, s e,, 3 C, TM.guaw p.

A%

w

.Samm*

89 2693 (sMAWLAW WsM)

. DuaNECMEE L.CM A E L m. = A D"OE N D A,v e O ROwOO,,A,M A s

= Amu *uoENeuCs, D C.

CMA=LEs M.-ONTANot C

T ea,,,

ERNE ST L B6AmE. JM P C.

JE AN M GALLOwav*

C ABLE "sM A*L AW MANNAM E M UEBERMAN JE rrety w *AwpftwAN CA' LETON s JONE s. P C.

MN L Came.Ja JuorTM A YMowas a.3 ANTE 4,teC, JO.esup J s A > O's.E R mE NNEtM A G ALLC pe MAnvEv LM LOONJ.*EesEL.*C.

mCSE RT M GO4 DON ANQnEW O Elu DAv'O R Lewis m'CM Amo A. Saum a pate Cm LEioMTON Hi*

V'RG'NIA OFF #Cg THOMAS E C mOCmE R. JR m EN NE T'H J. NA T 4sC m M,Cag y,

  • C.

BONNst s GOTTutg c AvEmeACM J Twowas LE N AmT. s* C.

    • O* A mo M se*AFFEmwAN v'C ut e HamO'NG ALAN O wassEmwAN

@ *E VEN L ME LTZEN p C.

OEnonAM e sayste iso 4 FanM CmEOi? 04'vE ME L E"N vonE"Lu D'C M a

  • O "aA
  • EYI J #E ****

V'O" N

DELN O AuuC m. P C.

C Aw"etLL MILLE rt e SCC a ANEheEmG n+

aECmEm JOMN E **G E L M C

  • e Y

OCA" C. TMCM As M'Cas ne, p C.*

paul M TMOMas wCLE AN' vimO'Nia 22602 "t"N"N E"T'M' NOON E 'E R

  • *
  • E " Y * * *"O' *'C m'E R"M"A N O 0 u

MILL OOmOTME A w

....-E..E JCMN r. OE AtT*

  • A.="s = = v =+m=

S SCOTT CusTEg, Ja R*CM ANO s. BEATTY counsel westEn s ornECT OiAL Nue=SE E July 18, 1984 (202) 822-1215 Administrative Judges Ivan W.

Smith, Chairman Sheldon J. Wolfe Gustave A.

Linenberger, Jr.

Atomic Safety and Licensing Board U.S. Nuclear Regulatory Comisison Washington, D.C.

20555 In the Matter of Metropolitan Edison Company (Three Mile Island Nuclear Station, Unit No. 1)

Docket No. 50-289 (Restart - Remand)

Dear Chairman Smith and Administrative Judges Wolfe and Linenberger:

In a letter dated July 5, 1984, Licensee's counsel advised the Board that TMI-l could be physically ready to operate by the middle of July.

In its July 5 letter, Licensee also en~

closed two letters it had sent to the Staff on the steam gener-ator leakage recently detected at THI-1.

Due to recent unanticipated events in the steam generator tube plugging pro-gram, as indicated in the attached letter from Mr. Hukill, 8407190408 840718 PDRADOCK05000g a

s i

= -

4 SHAW, PITTMAN. PoTTs & TROW; RIDGE A 36mTMtmeseep OF PROrtenecesAk COW 80mAftONS Ivan W. Smith, Esquire Sheldon J. Wolfe, Esquire f

Mr. Gustave A. Linenberger, Jr.

i July 18, 1984 Page 2 Director, TMI-1, to Mr. Stolz, Office of Nuclear Reactor Regu-lation, the return to service of TMI-l is not expected before August, 1984.

Sincerely, b& 0. &1%

Deborah B. Bauser Counsel for Licensee a

DBB:jah Enclosure cc:

Service List l

i j

4 I

i c

. 0 1

s k

~

UNITED STATES OF AMERICA j.

NUCLEAR REGULATORY COMMISSION 4

4 I

Before the Commission f

In the Matter of

)

)

METROPOLITAN EDISON COMPANY

)

Docket No. 50-289 SP

)

I (Three Mile Island Nuclear

)

, (Restart - Management Phase)

Station, Unit No. 1)

)

,i i

SERVICE LIST i

Nunzio J. Palladino, Chairman Administrative Judge U.S. Nuclear Regulatory Commission John H.

Buck Washington, D.C.

20555 Atomic Safety & Licensing Appeal Board i.

Thomas M. Roberts, Commissioner U.S. Nuclear Regulatory Commission '

i U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Washington, D.C.

20555 i

Administrative Judge James K. Asselstine, Commissioner-Christine N. Kohl U.S. Nuclear Regulatory Commission Atomic Safety & Licensing Appeal Washington, D.C.

20555 Board-U.S. Nuclear Regulatory Commission Frederick Bernthal, Commissioner Washington, D.C.

20555 U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Administrative Judge Ivan W.

Smith, Chairman Lando W.-Zeck, Jr., Commissioner Atomic Safety & Licensing Board JU.S. Nuclear Regulatory Commission U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Washington, D.C.

20555 4

Administrative Judge Administrative Judge Gary J. Edles, Chairman Sheldon J.EWolfe Atomic Safety & Licensing Appeal Atomic Safety & Licensing Board Board U.S. Nuclear Regulatory Commission U.S. Nuclear Regulatory Commission Washington, D.C.

20555 l

Washington, D.C.

20555-d s

9

,y 3c-m

-vy, yv-*.

e Administrative Judge Mr. Henry D.

Hukill Gustave A. Linenberger, Jr.

V;ce President Atomic Safety & Licensing Board GPU Nuclear Corporation U.S. Nuclear Regulatory Commission P.O. Box 480 Washington, D.C.

20555 Middletown, PA 17057 Docketing and Service Section (3)

Mr. and Mrs. Norman Aamodt Office of the Secretary

. R.D.

5 U.S. Nuclear Regulatory Commission Coatesville, PA 19320 Washington, D.C.

20555 Ms. Louise Bradford Atomic Safety & *icensing Board TMI ALERT Panel 1011 Green Street U.S. Nuclear Regulatory Commission Harrisburg, PA 17102 Washington, D.C.

20555 Joanne Doroshow, Esquire Atomic SA 'ety & Licensing Appeal The Cnristic Institute Board Panel 1324 North Capitol Street U.S. Nuclear Regulatory Commission Washington, D.C.

20002 Washington, D.C.

20555 Lynne Bernabei, Esq.

G vernment Accountability Jack R.

Goldberg, Esq. (4)

Office of the Executive Legal 15 5 C nnecticut Avenue Washington, D.C.

20009 U.S Nuc ear Regulatory Commission Washington, D.C.

20555 Ellyn R. Weiss, Esq; Harmon, Weiss & Jordan Thomas Y. Au, Esq.

2001 S Street, N.W.,

Suite 430 Office of Chief Counsel Washington, D.C.

20009 Department of Environmental Resources Michael F.

McBride, Esq.

505 Executive House LeBoeuf, Lamb, Leiby & MacRae P.O. Box 2357 1333 New Hampshire Avenue, N.W.

Harrisburg, PA 17120 Suite 1100 Washington, D.C.

20036 Michael W.

Maupin, Esq.

Hunton & Williams 707 East Main Street P.O. Box 1535 Richmond, VA 23212 1

d

I GPU Nuclear Corporation duclear

: :,o " a
  • Middletown, Pennsylvania 17057-0191 717 944 7621 TELEX 64 2346 Writer's Direct Dial Namber:

July 18, 1984 5211-84-2184 Office of Nuclear Reactor Regulation Attn:

John F.

Stolz, Chief Operating Reactors Branch No. 4 U. S. Nuclear Regulatory Commission Washington, D.C.

20555

Dear Mr. Etolz:

Three Mile Island Nuclear Station, Unit 1, (TMI-1)

Operating License No. DPR-50 Docket No. 50-289 Steam Generator Tube Pluggine Update The purpose of this letter is to provide you with a current status '

of recent tube plugging efforts.

This information supplements the information provided to you by my letters of June 27, 1984 and July 3, 1984.

The status of recently plugged tubes is provided on the enclosed table.

The tabulated tubes have been plugged or dispositioned as not requiring plugging.

In addition to the above tubes, 5 Westinghouse rolled plugs (3 in the "A" OTSG and 2 in the "B" OTSG) were discovered missing from the lower tube sheets.

These missing plugs were discovered during a 100% reconfirmation that was performed as a result of the plugging problems identified in the OTSG upper tube sheets.

The 5 missing plugs are believed to be lost in the reactor coolant system probably in the reactor vessel.

Efforts are underway to determine the cause of the plugs being dislodged and the need, if ar.y, for retrieving them at this time.

Based on the above, the schedule suggested in my July 3, 1984 letter is ch.:nged.

No firm revised schedule for return to service has been established.

However, return to service 17 not expected before August 1984. We will inform you of our revised schedule as soon as sufficient information is available.

Sincerely, l

l HDH/CWS/jrg K

ill Enclosure Director, TMI-l cc:

R. Conte J. Van Vliet GPU Nuclear Corporation is a' subsidiary of the General Public Utilities Corporation 31

OTSG tunes PLUGGED SINCE JUNE 27 1984 0

OToG TUDE NUMilER PLUG TYPE REASON FOR PLUGGING A

i35-72 Welded plug UTS An adjacent tube (134-74) was plugged in error instead of tube 135-72. Tube 135-72 was plugged to correct the error A

148-35 Welded plug UTS Tube 148-35 was plugged previously.

The plug is believed to have been dislodged and relocated.to tube 65-38.

The plug was removed from tube 65-38 and a plug was re-installed in tube 148-35 as required.

p 80-45 Wolded plug UTS See letters dated June 27, 1984 Explosive plug LTS and July 3, 1984 B

_77-07 Explosive plug LTS A second explosive plug was installed in the LTS to correct a previously installed explosive. plug that was leaking.

n 79-41 Welded plug UTS This tube was plugged as a precaution Explosive plug LTS since it was leaking more than desired.

(See also letter dated July 3, 1984) u 70-08 Wolded plug UTS A re-review of the ECT tapes for the Explosive plug LTS approximately 70 " sample population" tubes identified a defect which had been present in previous ECT tapes but was missed during reviews because it was at the. threshold of ECT sensitivity.

Therefore, this tube was plugged as required.

i

-