Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- NLS8800109, Application for Amend to License DPR-46,revising Tech Specs Re Standby Liquid Control Sys.Evaluation of Changes Per 10CFR50.92 Requirements Encl.Fee Paid + (07:41:38, 11 December 2024)
- ML20153E940 + (07:41:39, 11 December 2024)
- ML20153E938 + (07:41:39, 11 December 2024)
- ML20153E936 + (07:41:40, 11 December 2024)
- ML20153E935 + (07:41:41, 11 December 2024)
- ML20153E934 + (07:41:41, 11 December 2024)
- ML20153E933 + (07:41:42, 11 December 2024)
- ML20153E931 + (07:41:42, 11 December 2024)
- ML20153E930 + (07:41:43, 11 December 2024)
- ML20153E929 + (07:41:44, 11 December 2024)
- NLS88000136, Application for Amend to License DPR-46,consisting of Proposed Change 58,revising Tech Specs to Reflect Changes to Undervoltage Relays During Current Refueling Outage.Fee Paid + (07:41:44, 11 December 2024)
- ML20153E925 + (07:41:45, 11 December 2024)
- B12864, Northeast Nuclear Energy Co Millstone Unit 2 Reactor Containment Bldg Integrated Leak Rate Test + (07:41:46, 11 December 2024)
- ML20153E922 + (07:41:48, 11 December 2024)
- ML20153E921 + (07:41:48, 11 December 2024)
- ML20153E918 + (07:41:49, 11 December 2024)
- ML20153E915 + (07:41:50, 11 December 2024)
- ML20153E916 + (07:41:50, 11 December 2024)
- 3F0588-02, Cycle 7 Startup Rept + (07:41:51, 11 December 2024)
- ML20153E913 + (07:41:52, 11 December 2024)
- ML20153E912 + (07:41:52, 11 December 2024)
- ML20153E909 + (07:41:53, 11 December 2024)
- TAC:60982 + (07:41:54, 11 December 2024)
- IR 05000010/1988003 + (07:41:56, 11 December 2024)
- ML20153E907 + (07:41:56, 11 December 2024)
- ML20153E902 + (07:41:57, 11 December 2024)
- ML20153E900 + (07:41:58, 11 December 2024)
- ML20153E901 + (07:41:58, 11 December 2024)
- ML20153E899 + (07:41:59, 11 December 2024)
- ML20153E897 + (07:41:59, 11 December 2024)
- ML20153E896 + (07:42:00, 11 December 2024)
- ML20153E893 + (07:42:01, 11 December 2024)
- ML20153E894 + (07:42:01, 11 December 2024)
- 05000339/LER-1988-019, :on 880407,surveillance Test for Steam Generator Surface Sample Line Outside Containment Isolation Valve Not Performed within Interval Allowed by Tech Specs. Caused by Personnel Error.Program Modified + (07:42:03, 11 December 2024)
- ML20153E888 + (07:42:04, 11 December 2024)
- ML20153E885 + (07:42:05, 11 December 2024)
- ML20153E887 + (07:42:05, 11 December 2024)
- ML20153E884 + (07:42:06, 11 December 2024)
- ML20153E881 + (07:42:07, 11 December 2024)
- ML20153E882 + (07:42:07, 11 December 2024)
- ML20153E879 + (07:42:08, 11 December 2024)
- ML20153E880 + (07:42:08, 11 December 2024)
- ML20153E877 + (07:42:09, 11 December 2024)
- 05000277/LER-1988-009-01, :on 880404,treated Liquid Radwaste Effluent Released W/O Prior Sampling.Caused by Personnel Error. Individual Counseled on Importance of Attention to Detail + (07:42:11, 11 December 2024)
- ML20153E874 + (07:42:12, 11 December 2024)
- ML20153E873 + (07:42:12, 11 December 2024)
- ML20153E871 + (07:42:13, 11 December 2024)
- ML20153E872 + (07:42:13, 11 December 2024)
- 05000278/LER-1987-001-03, :on 880408,actuation of Primary Containment Isolation Sys Occurred During Switching of 4 Kv Emergency Bus Feed.Caused by Lack of Procedural Guidance & Training for Operators.Training Bulletin Issued + (07:42:15, 11 December 2024)
- ML20153E867 + (07:42:17, 11 December 2024)
- PNO-III-86-014, on 860212 & 17,emergency Diesel Generator 2A Failed.Caused by Broken Rocker Arms on Left Cylinders 5 & 7, Respectively.Station Will Be Shut Down for 16 Days While Licensee Investigates Problem + (07:42:18, 11 December 2024)