Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20210K223 + (February 11, 1994)
- ST-HL-AE-4685, Discusses Status of Upgrades to STP Employee Concerns Program + (February 11, 1994)
- NRC-94-4063, Forwards Nonproprietary & Proprietary Versions of Addendum 2 to Rept Entitled, Bypass Logic for Westinghouse Integrated Protection Sys,AP600 Bypass Logic Implementation Description. Proprietary Version of Rept Withheld + (February 11, 1994)
- NG-94-0336, Responds to Violation Noted in Insp Rept 50-331/93-19 Re Facility GL 89-10 MOV Program.Corrective actions:re- Evaluation of Votes Data on All GL 89-10 Valves Tested Prior to Refueling Outage 12 Will Be Completed by 940401 + (February 11, 1994)
- ULNRC-02950, Forwards Callaway Refuel 6 ISI Summary Rept + (February 11, 1994)
- NRC-94-4062, Forwards Proprietary Quick Look Rept for Large Scale Pccs Test 221.1,AP60 Program, PCS-T2R-023.Rept Withheld,Per 10CFR2.790.Rept Describes Results of Test Performed at AP600 Pccs Large Scale Test Facility + (February 11, 1994)
- NG-94-0370, Responds to Deviation Noted in Insp Rept 50-331/93-19 on 931129-1209 of Commitments to GL 89-10.Corrective Actions: MOV Team Expanded & Has Been Reconstructed to Ensure Timely & Accurate Responses to NRC Commitments Re GL 89-10 + (February 11, 1994)
- ST-HL-AE-4699, Special Rept:On 940113,SDG 12 Output Breaker Tripped.Caused by Voltage Regulator (Vr) Failure.Final Test Rept from Vr Vendor Will Be Evaluated to Determine If Addl Actions Required to Increase Reliability of Vr Module + (February 11, 1994)
- HL-4494, Comment on Draft NUREG/CR-5884 & Draft NUREG/CR-6054 Published in Fr on 931021.Util in Total Agreement W/Numarc Comments + (February 11, 1994)
- ML23156A090 + (February 11, 1994)
- PY-CEI-NRR-1750, Forwards Response to NRC RAI Received on 931229 Re GL 92-08 Thermo-Lag 330-1 Fire Barriers + (February 11, 1994)
- PY-CEI-NRR-1751, Forwards Changes to ERDS Data Point Library & ERDS Communication Description for Facility + (February 11, 1994)
- ML20266C973 + (February 11, 1994)
- 05000425/LER-1994-002, :on 940119,CR Personnel Received Alarm for Trip of B Heater Drain Tank Pump.Caused by Loss of B Heater Drain Tank Pump,Likely Caused by Spurious Actuation of Level Sensor.Level Switches & Sensing Lines Cleaned + (February 11, 1994)
- 05000325/LER-1994-002-01, :on 940117,common Control Bldg Heating Ventilation & Air Conditioning Air Conditioners Tripped. Caused by Gradual Decrease in Refrigerant Charge Pressure During Yrs of Svc.Pressure Range Established + (February 11, 1994)
- 05000395/LER-1994-001, :on 940113,Appendix R Analysis Determined to Be Outside Design Basis Due to Analysis for Circuits Susceptible to Hot Shorts.Caused by Personnel Error.Fire Watch Patrols Established for Zones Effected + (February 11, 1994)
- 05000456/LER-1993-006-01, :on 931209,MDAFWPs Declared Inoperable & LCO Action Requirement 3.7.1.2.a Entered Due to Potential Unavailability of MDAFWPs During Stated Scenario.Temporary Alterations 93-1-018 & 93-2-025 Installed + (February 11, 1994)
- 05000458/LER-1994-004, :on 940113,nonconservative Alarm Setpoint for Liquid Radwaste Gross Activity Monitor 1RMS-RE107.Caused by Personnel Error.Alarm Setpoint for Monitor 1RMS-RE107 Revised to Assure Setpoint Properly Set + (February 11, 1994)
- ML18022A924 + (February 11, 1994)
- GO2-94-039, Provides Summary of Licensees Planned Actions & Schedule for Completion Re Employee Concerns Program Status.Licensee Response to Special Insp Rept 50-397/93-51 Can Be Separated Into Three General Areas + (February 11, 1994)
- ML17228A483 + (February 11, 1994)
- ML15261A308 + (February 11, 1994)
- ML15261A313 + (February 11, 1994)
- ML15261A312 + (February 11, 1994)
- ML16154A556 + (February 11, 1994)
- ML20138E304 + (February 11, 1994)
- RC-94-0032, Forwards Rev 33 of EPP-100, Radiation Emergency Plan + (February 11, 1994)
- ML20063J885 + (February 11, 1994)
- ML20065N624 + (February 12, 1994)
- ML20266F071 + (February 13, 1994)
- ML20266E968 + (February 13, 1994)
- ML20266F075 + (February 13, 1994)
- ML20266F137 + (February 13, 1994)
- ML20266F124 + (February 13, 1994)
- ML20266F142 + (February 13, 1994)
- ML20266F068 + (February 13, 1994)
- ML20266F128 + (February 13, 1994)
- ML20064K254 + (February 14, 1994)
- ML20064G838 + (February 14, 1994)
- ML20064G108 + (February 14, 1994)
- ML20063L568 + (February 14, 1994)
- ML20063K853 + (February 14, 1994)
- ML20063K748 + (February 14, 1994)
- ML20063K622 + (February 14, 1994)
- 3F0294-14, Informs That Attached Data Points Complete Necessary Library for ERDS Program for Unit 3 & Incorporated Into Sys on 940207 + (February 14, 1994)
- ML20063K279 + (February 14, 1994)
- ML20063K094 + (February 14, 1994)
- ML20063K092 + (February 14, 1994)
- ML20063K090 + (February 14, 1994)
- ML20063K033 + (February 14, 1994)
- ML20063K032 + (February 14, 1994)
- ML20063K011 + (February 14, 1994)
- ML20063J997 + (February 14, 1994)
- ML20063J993 + (February 14, 1994)
- ML20063J923 + (February 14, 1994)
- ML20063J844 + (February 14, 1994)
- ML20063J825 + (February 14, 1994)
- ML20063H740 + (February 14, 1994)