- 05000277/LER-1976-042-03, /03L:on 760528,three Liquid Radwaste Releases Made W/Gross Activity Recorder Inoperable.Caused by Defective GE 1095K66707 Recorder Amplifier.Amplifier Replaced & Monitor & Recorder Recalibr & Returned to Svc +
- 05000271/LER-1976-016-03, /03L:on 760614,level Switch 23-91A Would Not Actuate at Tech Spec Trip Level Setting.Caused by Stuck Float Inside Level Switch Chamber.Switch Chamber Flushed, Causing Float to Become Freed & Operable +
- 05000254/LER-1976-019-01, /01T-0:on 760617,HPCI Motor Speed Changer Failed to Operate During Monthly Surveillance.Caused by Inadequate Lubrication.Lubrication Schedule established.W/760701 Forwarding Ltr +
- 05000220/LER-1976-025, :on 760627,average Power Range Monitors 11 & 15 Failed to Produce Scram Signal at Required Flow Bias Setpoint.Caused by Setpoint Drift.Instruments Calibr to Required Specs +
- 05000220/LER-1976-024, :on 760613,average Power Range Monitors 17 & 18 Failed to Produce Scram Signal at Required Flow Bias Setpoint.Caused by Setpoint Drift.Instrument Recalibr to Required Specs +
- 05000220/LER-1976-023, :on 760625,smoke Observed from Relay 4-112 B/40. Caused by Apparently Shorted Coil,Resulting in Blown Fuse. Relay Replaced +