- U-602049, Ro:On 920922,Control Room Received Notification That Employee Working in Radwaste Sort Tent Had Been Injured & Potentially Contaminated.Ambulance Called to Respond.Hosp Notified Util That Victim Was Not Contaminated +
- JAFP-84-0823, Effluent & Waste Disposal Semiannual Rept for Jan-June 1984 +
- ML24008A108 +
- ML24208A040 +
- 05000352/LER-1989-043, :on 890628 & 29,refuel Floor HVAC Sys Isolated Due to Inadequate Differential Pressure Between Outside & Refuel Floor Atmospheres.Caused by Procedural Deficiency. Secondary Containment Isolation Switches Reset +
- 05000461/LER-1989-029, :on 890714,manual Scram Initiated in Anticipation of Automatic Scram Due to Decrease in Main Condenser Vacuum.Caused by Mechanical Failure in Rubber Expansion Joint.Joint Replaced +
- 05000461/LER-1987-064, :on 871102,Div 3 Diesel Generator Automatically Started While Technician Disconnected Undervoltage Relay. Caused by Inadequate Procedure & Personnel Error.Procedure Revised & Technicians Trained +
- 05000352/LER-1987-048, :on 870919,reactor Scrammed Following Main Turbine Trip on electro-hydraulic Control Low Oil Pressure. Caused by Failure of Tubing Socket Weld in Fluid Actuating Supply Line.Failed Weld Replaced W/New Section +
- ML20212G055 +
- ML20206K648 +
- 05000414/LER-1986-028-01, :on 860627,safety Injection Actuated on Low Pressurizer & Main Steam Line Pressure.Pressure Decreased Due to Inadvertent Opening of Porvs.Caused by Procedure Deficiency.Procedure Revised +
- 05000461/LER-1986-003, :on 860930,control Room Ventilation Sys Train B Shifted to High Chlorine Mode of Operation.Caused by Broken Detector Tape in Chlorine Detector Due to Excess Spring Tension Causing Excessive Drag on Tape.Tape Rethreaded +
- 05000382/LER-1985-038, :on 850910,discovered That Fire Wrap for Conduits 31509C-2A & 31551R-SA Did Not Completely Cover Support Points.Cause Not Stated.Condition Existed Since Const.Points Wrapped & Operability Verified +
- 05000461/LER-1991-007, :on 911212,B RWCU HX Room Air Handling Unit Fan Failed,Resulting in Inoperable Leak Detection Instruments.Cause Under Investigation.B RWCU HX Room Air Handling Unit Reworked +
- 05000352/LER-1990-029-01, :on 901128,personnel Received Main Control Room Annunciator Alarm Associated W/Toxic Gas Detection Sys. Caused by Failure of Toxic Gas Analyzer Memory.Vendor Contacted to Provide Addl Actions +
- 05000333/LER-1994-001, :on 940224,HPCI Sys Had Declared Inoperable Due to Turbine Shaft Seal Leakage.Caused by Corrosion of Gland Seal Casing & Pitting.New Turbine Shaft Seals Installed.W/ +
- 05000333/LER-1994-001-01, :on 940224,HPCI Sys Declared Inoperable Due to Minor Corrosion on Gland Seal Casing & Pitting of Turbine Shaft in Seal Area.New Turbine Shaft Seals Installed +
- 05000261/LER-1982-010-01, /01T-0:on 820803,control Rod Drive Mechanism for Rod L-11 Observed to Have Steam Leaking from 1/4-inch Vent Valve at Top.Caused by Vent Valve Being Improperly Torqued Shut During Repair in 1982 Outage +
- ML20009D892 +
- 05000352/LER-1989-059, :on 891206,instrumentation & Controls Technician Inadvertently Grounded Test Jack,Resulting in Blown Fuse.Caused by Personnel Error.Fuse Replaced. Technicians Counseled +
- ML20003F761 +
- 05000280/LER-1989-011, :on 890330,discovered That Hourly Fire Watch Patrol Required in Containment Not Present.Caused by Poor Communication Between Personnel Giving & Receiving Instructions.Air Recirculation Fan Started +
- L-92-248, Forwards Semiannual fitness-for-duty Performance Data for 6-month Period Ending 920630 +
- GO2-89-053, Submits Revised Response to NRC Re Violation B Noted in Insp Rept 50-397/88-24.Corrective Actions: Troubleshooting Procedure Will Be Revised.Addl Info Re Verbal Procedure Deviations Also Encl,Per Request +
- 05000387/LER-2015-013, Regarding Loss of Differential Pressure in Zone I of Secondary Containment Due to Solenoid Valve Failure +
- 05000260/LER-2003-002, Re High Pressure Coolant Injection (Hpc) Inoperability Due to Loss of Turbine Speed Feedback Signal +
- 05000341/LER-1988-004, :on 880110,north Reactor Feed Pump Speed Control Failed Resulting in Low Reactor Vessel Water Level. Caused by Overvoltage Trip for Power Supply.Failed Power Supply Replaced +
- 05000414/LER-1994-007-01, :on 941018,reactor Trip Occurred & TS Violated. Caused by Document Use Practices & Less than Adequate Mgt Directions.Cr Operators Entered Appropriate Emergency Procedures & Stabilized Plant +