Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000325/LER-2005-004 +
- ML17219A623 +
- ML17319A645 +
- ML17317B203 +
- ML17317B199 +
- ML092230129 +
- ML20012C529 +
- ML19056A409 +
- ML20040G119 +
- ML20053C927 +
- ML023650520 +
- ML023520337 +
- ML20246G111 +
- ML20236R119 +
- ML20236Q333 +
- ML20236Q331 +
- ML20215G857 +
- RBG-23721, Monthly Operating Rept for Apr 1986 +
- 05000260/LER-1989-017, :on 890607,intermediate Range Monitors C,G & H of Neutron Monitoring Sys Received hi-hi Signal.Caused by Failure to Implement Action to Disable Tungsten Inert Gas Auto Start Function.Memo Issued to Managers +
- 05000346/LER-1987-014, :on 871125,determined That Deficiency Which Occurred During Performance of Fire Hose Hydrostatic Test Made Fire Hose Station Inoperable from 871022-26.Caused by Inadequate Procedural Guidance +
- 05000334/LER-1987-013, :on 870609,reactor Tripped Due to High Power Range Negative Flux Rate.Caused by Dropped Rods Due to Failure of Firing Circuit Card in Control Power Cabinet.Card Replaced & Mod to Ventilation Sys Implemented +
- 05000293/LER-1999-008-02, :on 990805,automatic Scram Occurred While at 100% Power Due to Automatic Turbine Trip.Caused by Malfunction of Moisture Separator Drain Tank a Drain Valve Controller.Level Controllers Replaced.With +
- 05000281/LER-1984-005-01, :on 840316,reactor Trip Occurred as Result of Reactor Coolant Pump Trip.Caused by Water in Electrical Penetration for Motor Leads.Penetration Replaced W/Spare & Meggered & Type B Tested Satisfactorily +
- 05000338/LER-1984-003-02, :on 840208,turbine trip-reactor Trip Occurred Due to Spurious electro-hydraulic Control Fluid Reservoir Low Level Turbine Trip Signal.Caused by Pump Vibration Due to Unloader Malfunction.Unloaders Readjusted +
- 05000352/LER-1991-021-01, :on 910829,high Toxic Chemical Concentration Alarm Received in Main Control Room,Resulting in Control Room Ventilation Sys Isolation.Caused by Inadequate Procedural Guidance.New Procedure Written +
- 05000339/LER-1994-002, :on 940106,discovered That ASME Code Exam Were Not Performed as Required Due to Failure to Follow Procedure.Held Conference Call to Discuss Relief from Code Requirements +
- 05000346/LER-1993-005, :on 931008,RT Occurred Due to CRD Trip Confirm Signal Caused by Degraded Power Supply in CRD Sys Logic Cabinet 1.Replaced Degraded Power Supply & CRD Logic Protection Circuit +
- 05000412/LER-1993-011-01, :on 931006,containment Closure Deficiency During Refueling Occurred.Caused by Incomplete Installation of Temporary Seal on Spare Penetration Through Primary Containment Bldg.Control Room Notified +
- ST-HL-AE-3422, Final Special Rept:On 891128,diesel Generator Valid Failure Occurred.Caused by Presence of Improperly Drilled & Repaired Oil Passage Hole Serving Articulated Rod Pin Bushing in Master Connecting Rod Assembly.Crankshift Webs Repaired +
- 05000414/LER-1993-001-01, :on 930221,essential Auxiliary Power Sys Blackout Occurred When DG 2B Removed from Svc.Caused by Missed Procedure.On 930222,problems W/Train a CR Area Ventilation Sys Occurred.Procedures Revised +
- ML20034C057 +
- ML19341A229 +
- ST-HL-AE-3326, Special Rept:On 891128,valid Failure of Diesel Generator Occurred.Caused by Improperly Drilled Oil Passage on Master Rod.Remedial Actions to Restore Standby Diesel Generator 22 Includes Crankshaft Straightening & Remachining +
- PLA-8058, Annual Radiological Environmental Operating Report (PLA-8058) +
- ML18041A199 +
- 05000397/LER-1995-006, :on 950405,reactor Scram Occurred During Surveillance Testing Due to Protective Sys Relay Failure. Replaced Failed Relay Before Plant Startup +
- 05000397/LER-1990-017, :on 900830,31,0906,17 & 18,HPCS Sys Inoperable as Result of 125-volt Dc Battery Inoperability.Caused by Functional Design Deficiency.Mod Planned to Battery Racks & Encls.Also Reported Per Part 21 by Limitorque +
- 05000270/LER-2015-001, Regarding Valid Emergency Feedwater System Actuation Caused by a Main Feedwater System Block Valve Malfunction +
- 05000254/LER-2006-003, Regarding Unexpected Start of the Division II Emergency Diesel Generator Due to Failure to Open Test Switch +
- 05000293/LER-1999-008-01, Regarding Automatic Scram at 100 Percent Power Due to Turbine Trip +
- 05000498/LER-1994-016, :on 940923,failure to Fully Meet Requirements of TS Due to Not Placing CR Envelope HVAC Sys in Required Mode.Toxic Gas Analyzers Repaired & Mod Implemented +