- ML11271A027 +
- ML112590091 +
- ML110730473 +
- ML101260445 +
- ML100980050 +
- ML081260528 +
- ML080730131 +
- ML080650559 +
- ML061940105 +
- 05000311/LER-1990-031, :on 900802,valve 21MS18 Main Steam Line Isolation Control Circuit Failed to Close.Caused by Failure to Wire Control Circuitry Per design.Seal-in Contacts Removed from Circuit & Circuit Adjusted +
- ML18054A487 +
- ML19260A226 +
- ML19296D172 +
- ML20050B185 +
- ML20042A434 +
- ML040330908 +
- ML20107A693 +
- ML20113F294 +
- ML20113D409 +
- ML20147G463 +
- ML20244B826 +
- ML20249A560 +
- ML20247L784 +
- ML20246E848 +
- ML20236V861 +
- ML20235T962 +
- ML23166B088 +
- 05000280/LER-1986-034, :on 861117,control/relay Room Chiller C Tripped Due to High Condenser Pressure,Leaving Only One Operable Chiller,In Violation of Tech Specs.Caused by Clogged Suction Strainer.Strainer Cleaned +
- 05000272/LER-1981-094, Forwards LER 81-094/01T-0.Detailed Event Analysis Encl +
- 05000272/LER-1981-094-01, /01T-0:on 811028,containment for Coil Unit 14 Declared Inoperable.Caused by 0.8 Gpm Leak in Fifth & Sixth Primary Coils.Leaks Repaired W/Belzona Metal Filler.Cooler to Be Replaced +
- A00523, Forwards Supplemental Response to IE Bulletin 79-15, Deep Draft Pump Deficiencies, Per NRC 810623 Request.Provides Justifications for Reliability of Emergency Svc Water Pumps Re long-term Cooling Operability +
- ML20024E769 +
- ML20035A229 +
- ML20053B939 +
- ML19242D573 +
- 05000280/LER-1989-010, :on 890406,electrical Fault in Plant Switchyard Resulted in Failure of Lightning Arrestor on 500 Kv Side of auto-tie Transformer,Resulting in Lockout.Cause Not Determined.Offsite Power Supply Reestablished +
- ML18094A619 +
- IR 05000272/1988099 +
- TSTF-05-16, TSTF-490, Revision 0, Deletion of E Bar Definition and Revision to RCS Specific Activity Tech Spec +
- 05000219/LER-1987-027, :on 870730 & 31,containment Isolation & Standby Gas Treatment Sys Initiation Occurred Due to Automatic Electrical Bus Transfer.Caused by Lightning Strike.Power Supply Will Be Changed to Continuous Source +
- IR 05000338/1987024 +
- 05000338/LER-1987-017, :on 870715,unit Manually Tripped.Caused by Indications of Steam Generator Tube Rupture in Steam Generator C.Cooldown & Depressurization of RCS Conducted Per Station Emergency Operating Procedures +