RCS Specific Activity 3.4.16 3.4 REACTOR COOLANT SYSTEM (RCS) 3.4.16 RCS Specific Activity LCO 3.4.16 The specific activity of the reactor coolant shall be within limits.

RCS DOSE EQUIVALENT I-131 and DOSE EQUIVALENT XE-133 specific activity shall be within limits.

APPLICABILITY: MODES [1, 2, 3, and 4.] [1 and 2, MODE 3 with RCS average temperature (Tavg)500°F.]

ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A. DOSE EQUIVALENT --------------------NOTE-------------------

I-131 not within LCO 3.0.4.c is applicable.

limit> 1.0µCi/gm. ------------------------------------------------

A.1 Verify DOSE EQUIVALENT Once per 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> I-131 within the acceptable region of Figure 3.4.16-1

[60] Ci/gm.

AND A.2 Restore DOSE 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> EQUIVALENT I-131 to within limit.

B. Gross specific activity of --------------------NOTE-------------------

the reactor coolant not LCO 3.0.4.c is applicable.

within limit.DOSE ------------------------------------------------

EQUIVALENT XE-133 not within limit. B.1 Be in MODE 3 with 648 hours0.0075 days <br />0.18 hours <br />0.00107 weeks <br />2.46564e-4 months <br /> Tavg < 500°F.Restore DOSE EQUIVALENT XE-133 to within limit.

WOG STS 3.4.16-1 Rev. 3.0, 03/31/04