WOG 3.4.16 RCS Specific Activity for TSTF-490
ML112590091
Person / Time
Site: Technical Specifications Task Force
Issue date: 09/08/2011
From:
Office of New Reactors
To:
References
Download: ML112590091 (1)


Text

RCS Specific Activity 3.4.16 WOG STS 3.4.16-1 Rev. 3.0, 03/31/04 3.4 REACTOR COOLANT SYSTEM (RCS) 3.4.16 RCS Specific Activity LCO 3.4.16 The specific activity of the reactor coolant shall be within limits.

RCS DOSE EQUIVALENT I-131 and DOSE EQUIVALENT XE-133 specific activity shall be within limits.

APPLICABILITY:

MODES [1, 2, 3, and 4.] [1 and 2, MODE 3 with RCS average temperature (Tavg) 500°F.]

ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A. DOSE EQUIVALENT I-131 not within limit> 1.0 µCi/gm.


NOTE-------------------

LCO 3.0.4.c is applicable.

A.1 Verify DOSE EQUIVALENT I-131 within the acceptable region of Figure 3.4.16-1

[60] Ci/gm.

AND A.2 Restore DOSE EQUIVALENT I-131 to within limit.

Once per 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> 48 hours B. Gross specific activity of the reactor coolant not within limit.DOSE EQUIVALENT XE-133 not within limit.


NOTE-------------------

LCO 3.0.4.c is applicable.

B.1 Be in MODE 3 with Tavg < 500°F.Restore DOSE EQUIVALENT XE-133 to within limit.

648 hours0.0075 days <br />0.18 hours <br />0.00107 weeks <br />2.46564e-4 months <br />