- ENS 42978 +
- ML17319A593 +
- ML20045G551 +
- L-03-184, October 2003 Monthly Operating Report for Beaver Valley, Units 1 & 2 +
- ML20141A483 +
- ML20133G577 +
- ML20069A135 +
- ML20151U870 +
- IR 05000456/1987006 +
- ML20236R890 +
- ML20215B415 +
- 05000285/LER-1987-025-01, :on 870923,diesel Generator 2 Shutdown Due to High Coolant Temp.Caused by Presence of Residue Causing Pilot Valve That Directs Air Flow to Stick.Pilot Valve Inspected & Cleaned & Accumulator Drained +
- 05000413/LER-1986-004, :on 860115,invalid Grab Samples Obtained.Caused by Introduction of Flush Water Over 4-day Period Due to Stuck Turbine Bldg Sump Radiation Monitor Flush Inlet Valve. on 851221,valve 1EMF Declared Inoperable +
- 05000266/LER-1985-004, :on 850725,diesel Generators auto-started After Loss of Low Voltage Station Transformer 1X04.Caused by Power Failure Due to Lockout of Low Voltage Station Transformer 1X04.Transformer Returned to Svc +
- 05000254/LER-1985-012-03, :on 850327,0418 & 19,fuel Pool Radiation Monitors 1A & 1B Spiked Upscale,Energizing Fuel Pool High Radiation Alarms.Caused by Loose Capacitor in Radiation Monitor Sensor Unit.Connection Repaired +
- 05000413/LER-1984-018-02, :on 841023,in-core Thermocouple Tube Leakage Occurred.Caused by Separation of Stainless Steel Conduit from Swagelok Tube Fitting.Thermocouple Replaced +
- LIC-90-0167, Responds to NRC Re Violations & Deviations Noted in Insp Rept 50-285/89-40.Corrective Actions:Changes Made to Procedure AOP-17 & Procedure Generation Package Incorporated in Plant Procedures as Standing Order G-74 +
- ML20043B459 +
- ML20138G818 +
- ML20030C469 +
- 05000260/LER-1991-014, :on 910629,manual Reactor Scram Occurred Due to Bulk Suppression Pool Water Temp Exceeding Tech Spec Limit.Caused by Lack of Procedural Controls.Rcic Procedure Revised +
- 05000260/LER-1991-014-01, :on 910629,manual Reactor Scram Occurred Due to Bulk Suppression Pool Water Temp Exceeding Tech Spec Limits. Procedure for Operating Rcic,Noting Potential for Thermal Stratification of Suppression Pool,Revised +
- 05000400/LER-1997-013, :on 970508,entry Into Mode-6 Without Operable Components,Resulting in TS 3.0.4 Violation Occurred.Caused by Personnel Error.Personnel Involved Counseled +
- ML20063H474 +
- IR 05000285/1987027 +
- ML20235P000 +
- 05000414/LER-1993-004-05, :on 930131,ice Condenser Door Opened Due to RHR Sys Transient.Reportability Requirements Will Be Determined for Monentary Ice Condenser Door Opening Events & Nuclear Sys Directive 202 Will Be Revised +