- ENS 40636 +
- ENS 43968 +
- ENS 47582 +
- ML17033B533 +
- ML11341A157 +
- ML17264A601 +
- ML092820157 +
- 05000272/LER-1992-015, :on 920831,2A Control Air Header Inlet Air Operated Globe Valve Failed Closed,During Normal Power Operation.Caused by Design,Mfg,Const/Installation of Ssps Circuit.Design Change Implemented +
- L-06-070, Request for Notice of Enforcement Discretion Loss of Supplemental Leak Collection and Release System Filters +
- ML20041F583 +
- ML20039D571 +
- ML20053C217 +
- ML20092F449 +
- ML20091P572 +
- ML20106D496 +
- ML20133H142 +
- ML20133G471 +
- ML20125D174 +
- ML20153E083 +
- ML20309A612 +
- IR 05000263/2017002 +
- 05000280/LER-1986-006, :on 860124,specific Activity Sample of Reactor Coolant Showed Dose Equivalent I-131 Level of 1.22 Mci/Cc After Manual Reactor Trip from 42% Power.Caused by Fuel Element Defects in Core.Level Monitored Every 4 H +
- 05000352/LER-1987-056, :on 871014,reactor Encl Ventilation Isolation Occurred.Caused by Series of Events Related to Auxiliary Steam Boilers.Outside Assistant Operators Replaced Torch Tip on Auxiliary Boiler B +
- 05000373/LER-1986-037, :on 860908,primary Containment Isolation Sys Isolation of Groups II & IV Occurred.Caused by Inadequate Out of Svc Taken on Reactor Level Switch.Procedure LAP-900-4 Revised.Personnel Training Initiated +
- 05000382/LER-1997-007, :on 970309,discovered Addl Refueling Water Storage Pool Instrument Uncertainty.Caused by Inadequate Design for Reference Leg of Level Transmitters.Recalibrated Rwsp Transmitters & Conducted Tests +
- 05000302/LER-1996-008, :on 960304,discovered That Ambiguous Note Caused Misinterpretation of Improved TS (ITS) SR 3.4.12.1 & Failure to Perform Required Surveillance Prior to Mode Ascension.Its Bases for SR Will Be Revised +
- 05000461/LER-1992-001, :on 920104,failure of B Phase Main Power Transformer Led to Turbine Generator Trip & Reactor Scram. Caused by Internal Fault Leading to Transformer Replacement +
- 05000219/LER-1982-021, Forwards LER 82-021/01T-0.Detailed Event Analysis Encl +
- BVY-93-071, Monthly Operating Rept for June 1993 for Vermont Yankee Nuclear Power Station +
- 05000254/LER-1990-005-01, :on 900313,RCIC Turbine Steam Supply motor- Operated Valve MO-1-13-1-61 Failed to Open During Quarterly Test.Caused by Dirt build-up on Operating Roller.Roller Cleaned & Contactor Functionally Tested +
- IR 05000269/1976004 +
- 05000266/LER-1980-004-03, /03L-0:on 800409,w/plant at Normal Steady State, Emergency Diesel Generator Failed to Start During Routine Surveillance Test.Second Attempt Unsuccessful.Caused by Broken Vane in Starting Air Motor.Air Motor Replaced +
- 05000280/LER-1989-010, :on 890406,electrical Fault in Plant Switchyard Resulted in Failure of Lightning Arrestor on 500 Kv Side of auto-tie Transformer,Resulting in Lockout.Cause Not Determined.Offsite Power Supply Reestablished +
- 05000311/LER-1992-015-01, :on 920831,2A Control Air Header Inlet Air Operated Globe Valve Failed Closed.Caused by Test Voltage Intermittently Causing Solenoid Valve to pick-up.Corrective Actions Will Be Taken After Investigation +
- 05000311/LER-1989-004-02, :on 890304,containment Purge/Presssure Vacuum Relief Isolation Valves Isolated as Result of Failure of Containment Particulate Radiation Monitor.Caused by Inadequate Sys Design.Channel 2R11A Reset +
- 05000272/LER-1988-003-02, :on 880224,reactor Trip Occurred on False intermediate-range High Flux Signal.Caused by Personnel Error.Maint Mgt Completed Review of Circumstances Surrounding Event.Individual Counseled +
- ML18039A059 +
- 05000263/LER-1917-001, Regarding Reactor Scram and Group II Isolation Due to 11 Reactor Feed Pump (RFP) Removal from Service with 12 RFP Isolated +
- 05000387/LER-2015-012, Regarding Loss of Secondary Containment Differential Pressure Due to Icing of the Intake Supply Plenum Screens +
- ML18285A054 +
- ML20034F450 +
- L-99-038, Monthly Operating Repts for Feb 1999 for Bvps,Units 1 & 2. with +
- L-98-229, Monthly Operating Repts for Nov 1998 for Bvps,Units 1 & 2. with +
- 05000458/LER-1996-014, :on 960710,surveillances Were Missed Due to Human Errors.Caused by Personnel Errors,Procedural Inadequacies & Inadequate Reviews of Test Results.Plant Shut Down to Perform Missed Surveillance +
- 05000353/LER-1995-006, :on 950322,inadvertent Division 2 Loss of Coolant Accident Signal Occurred Due to Screws on Signal Common Bus Loose.Suspect Trip Unit for Card File E21A-Z4B Replaced +