- ML17328A885 +
- ML19323J048 +
- ML19318A156 +
- ML20045G551 +
- ML19262C371 +
- ML033040408 +
- IR 05000373/2003004 +
- ML031000236 +
- ML021580303 +
- ML20081M865 +
- ML20077N151 +
- ML20090J123 +
- ML20147E642 +
- ML20206Q695 +
- ML20214E954 +
- ML20211H069 +
- BVY-92-126, Monthly Operating Rept for Oct 1992 for Vermont Yankee Nuclear Power Station +
- 05000461/LER-1987-031, :on 870617,RWCU Sys Pumps Tripped & in-board Containment Isolation Valves Shut.On 870705,spurious Signal Received Isolating RWCU Sys.Caused by Failed Differential Temp Point Module.Module Replaced +
- 05000324/LER-1999-002-02, :on 990329,reactor Tripped.Caused by Failed Electrical Connections on Vibration Detector for Number 9 Main Turbine Bearing.Vibration Detectors for Main Turbine Number 9 Bearing Replaced.With +
- 05000416/LER-1985-014, :on 850401,Tech Spec Limiting Condition of Operation Action Statement Not Reported When Main Steam Line High Flow Isolation Channel a Remained Inoperable Beyond 2 H Limit & Required Trip Signal Not Provided +
- 05000352/LER-1991-018, :on 910618,primary Containment & Reactor Vessel Isolation Control Sys Actuations Occurred.Caused by Loss of Power to Distrubution Panel.Preventive Maint Tasks Written to Replace Inductors in Inverters Annually +
- 05000352/LER-1991-018-01, :on 910618,automatic Actuations Occurred of Unit 1 Primary Containment & Reactor Vessel Isolation Control.Caused by Inadequate Design.Inverter Inductor Replaced +
- 05000266/LER-1983-001-03, /03L-0:on 830104,during Normal Operation,Panel D-400 Became Inoperable.Caused by Failed Power Supply.Power Supply Replaced W/Upgraded Components +
- 05000413/LER-1994-007, :on 940608,operations Discovered Past Due Rept Surveillance Interval Exceeded for TS Surveillance 4.7.6.b for Train A.Caused by Inadequate Verbal Communication.Lead Personnel Instructed to Closely Monitor Test +
- 05000311/LER-1981-113, Forwards LER 81-113/03L-0.Detailed Event Analysis Encl +
- 05000311/LER-1981-113-31, /03L-0:on 811028,control Console Log Reading for Containment Spray Additive Tank Level Found Out of Spec & Declared Inoperable.Caused by Personnel Failure to Detect Instrument Fluctuation.Tank Filled & Level Adjusted +
- 05000312/LER-1989-012, :on 891113,control Room Alarms Received Indicating That All Four Channels of Radiation Monitor R-15045 Experienced Loss of Sample Flow.Caused by Personnel Error.Sample Flow Reinstated +
- 05000334/LER-2014-002, Regarding Turbine Driven Auxiliary Feedwater Pump Governor Oscillations Result in Pump Trip +
- 05000373/LER-2003-002, Regarding 1A and 0 Diesel Generators Inoperable Simultaneously Due to Inadvertent Partial C02 Actuation +
- 05000354/LER-1996-011, :on 960320,HPCIS Failed Surveillance & ADS Declared Inoperable Resulting in Entry Into TS 3.0.3.Caused by Personnel Error.Procedures Revised & Personnel Trained +