Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ENS 48761 +
- ML071340229 +
- ML18107A337 +
- ML050190165 +
- ML043370046 +
- ML031950451 +
- ML20101S551 +
- ML20101R666 +
- ML20094Q646 +
- ML20072U428 +
- ML20199D031 +
- ML20155F130 +
- ML20203D976 +
- ML20213H077 +
- ML20235S584 +
- ML20209G576 +
- 05000213/LER-1987-008, :on 870625,control Rod 31 Dropped Into Core & Overfeed to Steam Generator 2 Occurred.Caused by Faulty Fuse & Inadequate Maint Procedure,Respectively.Fuse Replaced & Procedure Revised +
- 05000133/LER-1986-001-02, :on 860327,temporary Loss of Ac Power & Isolation of Refueling Bldg Ventilation Sys Occurred.Caused by Procedural Error.Power Restored.Application for Plant Decommissioning Filed.All Fuel Removed +
- 05000334/LER-1997-040, :on 971210,inadequate Testing of Reactor Protection Sys P-8 Interlock,Was Identified.Caused by Vendor Design Error.Applicable Surveillance Test Procedures Were Revised to Include Manual Test +
- 05000374/LER-1988-010-07, :on 880831,unit Shutdown Due to Automatic Depressurization Sys Nitrogen Backup Pressure Regulator Failure.Caused by Slow Response of South Side Bottle Bank Regulating Valve.Compressors Repaired +
- 05000374/LER-1996-009-06, :on 961016,potential Degradation of Post Loss of Coolant ECCS Recirculation Capability Noted as Result of Discovery of Foreign Matl in Pressure Suppression Pool.Divers Performed Underwater Insp of PSP +
- 05000440/LER-1997-001, :on 970107,nonlicensed Operator Electrical Switching Error Results in Reactor Protection Sys & Other ESF Actuations Occurred.Caused by Personnel Error.Standing Instruction Issued & Procedures Enhanced +
- 05000382/LER-1985-013, :on 850404,feedwater Pump B Tripped on Low Suction Pressure.Caused by Broken Yoke.Flow Orifice Added to Recirculation Line in Order to Limit Condensate Bypass Flow to Condenser +
- 05000269/LER-1994-003-03, :on 940623,discovered That Failure of an Air Pressure Regulator Resulted in Kh Main Transformer Lockout Relay Actuation.Caused by Design Deficiency.Repaired Affected Air System Components +
- ML20039G264 +
- PLA-8095, 2023 Annual Radiological Environmental Operating Report (PLA-8095) +
- PLA-8122, Annual Radiological Environmental Operating Report (PLA-8122) +
- 05000244/LER-1977-023, Letter Forwarding Update Report LER 77-023/1X-1, Supplemental Report on Reportable Occurrence 77-023/1T, Control Rod Urgent Failure Rod Stop +
- L-90-230, Reactor Containment Bldg Integrated Leakage Rate Test Final Rept +
- 05000259/LER-2013-006-02, Regarding B Standby Liquid Control Pump Inoperable for Longer than Allowed by the Technical Specifications +
- 05000259/LER-2013-006, Regarding 1B Standby Liquid Control Pump Inoperable for Longer than Allowed by the Technical Specifications +
- 05000445/LER-2007-001, Regarding Emergency Diesel Generator Inoperable for Longer than Allowed by TS Due to Paint on Metering Rod +
- 05000446/LER-2003-002, Re Actuation of Auxiliary Feedwater System +
- ML19261B232 +
- 05000352/LER-1987-013, :on 870508,reactor Encl Secondary Containment Isolated Due to Low Differential Pressure Between Encl & Outside Environ.Caused by Personnel Error.Sign Posted on Filter Entry Hatch +