INDEX NUMBER SECTION OF PAGES Average Daily Unit Power Level..
....I Operating Data Report...
..2 Refueling Information..
.1 Monthly Operating Summany....
.1 Summary of Changes, Tests, and Experiments....
.1 l
l 9604160455 960414 PDR ADOCK 05000354 R
DOCKET NO.: 50-354 UNIT: Hope Creek DATE: 4/10/96 COMPLETED BY:
D. W. Lyons TELEPHONE: (609) 339-3517 AVERAGE DAILY UNIT POWER LEVEL MONTH MARCH 1996 DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net)
(MWe-Net)
I Q
17 Q
2 Q
18 9
3 9
19 Q
4 Q
20 Q
5 Q
21 9
6 Q
22 Q
7 9
23 Q
8 9
24 9
9 9
25 104 10 Q
26 167 11 Q
27 407 12 0
28 522 13 9
29 926 14 9
30 1077 15 9
31 1017 16 Q
l l
l
l l
l
~
DOCKET NO.: 50-354 UNIT: Hooc Creek DATE: 4/10/96 i
COMPLETED BY:
D. W. Lyons TELEPHONE: (609) 339-3517
)
i OPERATING DATA REPORT l
l OPERATING STATUS 1.
Reporting Period March 1996 Gross Hours in Report Period 744.
2.
Currently Authorized Power Level (MWt) 3293 l
Max. Depend. Capacity (MWe-Net) 1031 l
Design Electrical Rating (MWe-Net) 1067 l
3.
Power Level to which restricted (if any) (MWe-Net)
None 4.
Reasons for restriction (if any) i l
This Month Yr To Date Cumulative
]
1 5.
No. of hours reactor was critical 322.2 322.2 67246.I 6.
Reactor reserve shutdown hours 0.0 0.0 0.0 7.
Hours generator on line 164.4 164.4 66106.0 8.
Unit reserve shutdown hours 0.0 0.0 0.0 9.
Gross thermal energy generated (MWH) 333272 333272 211107521
)
l 10.
Gross electrical energy generated (MWH) 106701 106701 69932323 11.
Net electrical energy generated (MWH) 89788 73553 66790788 12.
Reactor service factor 43.3 14.8 82.7 13.
Reactor availability factor 43.3 14.8 82.7 l
14.
Unit service factor 22.1 M
81.3 15.
Unit availability factor 22.1 M
81.3 16.
Unit capacity factor (using MDC) 11.7 M
79.6 17.
Unit capacity factor (using Design MWe) 11.3 M
76.9 I 8.
Unit forced outage rate 0_J) 00 M
19.
Shutdowns scheduled over next 6 months (type, date, & duration):
20.
If shutdown at end of report period, estimated date of start-up:
l
l 4
DOCKET NO.: 50-354 UNIT: Hope Creek DATE: 4/10/96 COMPLETED BY:
D. W. Lyons TELEPHONE: (609)339-3517 OPERATING DATA REPORT l
UNIT SHUTDOWNS AND POWER REDUCTIONS MONTH MARCH 1996 METHOD OF SHUTTINO DOWN THE TYPE REACTOR OR F= FORCED DURATION REASON REDUCING CORRECTIVE NO.
DATE S= SCHEDULED (HOURS)
(1)
POWER (2)
ACTION / COMMENTS 1.
03/01/96, S
11/95 - 478.4 C
4 Refueling Outage 0000 hrs S
12/95 - 744.0 to S
01/96 - 744.0 03/25/96, S
02/96 - 696.0 014I hrs S
.03/96 - 577.7 2
03/25/96, S
0 C
5 This was the planned 0141 hrs -
start up and power to ascension testing 03/29/96, program following the 2220 hrs refueling outage.
l t
I i
i l
A DOCKET NO.: 50-354 l
l UNIT: Hope Creek DATE: 4/10/96 COMPLETED BY:
D. W. Lyons TELEPIIONE: (609) 339-3517 REFUELING INFORMATION MONTH MARCH 1996 1.
Refueling information has changed from last month:
Yes No X
2.
Scheduled date for next refueling (RF07):
4/5/97 3.
Scheduled date for restart following refueling:
6/4/97 4A. Will Technical Specification changes or other license amendments be required?
Yes No X
B.
Has the Safety Evaluation covering the COLR been reviewed by the Station Operating Review Committee (SORC)?
Yes No X
If no, when is it scheduled? To Be Determined for Cycle 8 COLR 5.
Scheduled date(s) for submitting proposed licensing action:
Not reauired.
6.
Important licensing considerations associated with refueling:
N/A 7.
Number ofFuel Assemblies:
A. Incore (prior to current refueling outage) 764 B. In Spent Fuel Storage (prior to RF06) 1240 C. In Spent Fuel Storage (after RF06) 1472 8.
Present licensed spent fuel storage capacity:
4006 Future spent fuel storage capacity:
4006 9.
Date oflast refueling that can be discharged 5/3/2006 to spent fuel pool assuming the present hcensed capacity; (EOCl3)
(Does allow for full-core off-load)
(Assumes 244 bundle reloads every 18 months until then)
(Does nqt allow for smaller reloads due to improved fuel) l l
i
(
l f
1 i
i 1
- DOCKET NO.: 50-354 UNIT: Hope Creek DATE: 4/10/96 COMPLETED BY:
D. W. Lyons TELEPHONE: (609) 339-3517 MONTHLY OPERATING
SUMMARY
MONTH MARCH 1996 The Hope Creek Generating Station commenced start up after the Sixth Refueling Outage at 0627 hours0.00726 days <br />0.174 hours <br />0.00104 weeks <br />2.385735e-4 months <br /> on j
March 18,1996 when the operators moved the mode switch to " start up." Criticality was achieved at 1350 hours0.0156 days <br />0.375 hours <br />0.00223 weeks <br />5.13675e-4 months <br /> on March I8,1996. The initial synchronization of the unit was at 0141 hours0.00163 days <br />0.0392 hours <br />2.331349e-4 weeks <br />5.36505e-5 months <br /> on March 25,1996. At l
1025 hours0.0119 days <br />0.285 hours <br />0.00169 weeks <br />3.900125e-4 months <br /> the generator was removed from senice and the post-outage overspeed test was successfully performed. At 1219 hours0.0141 days <br />0.339 hours <br />0.00202 weeks <br />4.638295e-4 months <br /> on March 25,1996 the unit was resynchron;2cd and power ascension resumed.
The outage was officially ended when 100% power was achieved at 2220 hours0.0257 days <br />0.617 hours <br />0.00367 weeks <br />8.4471e-4 months <br /> on March 29,1996. This resulted in unplanned off-line energy losses of 471398.7 MWHRS (96-04) for the outage extension, planned off-line energy losses of 174161.2 MWHRS (96-05) for the start-up, and planned on-line losses of 77460.1 l
MWHRS (96-06) for the power ascension.
l A stuck TIP probe, rod adjustments, and weekly turbine valve survcillances occurred between 0805 hours0.00932 days <br />0.224 hours <br />0.00133 weeks <br />3.063025e-4 months <br /> on March 30,1996 and 1318 hours0.0153 days <br />0.366 hours <br />0.00218 weeks <br />5.01499e-4 months <br /> on March 31,1996. These activities caused 2187.2 MWHRS of unplanned energy losses (96-08) and 150 MWHRS of planned energy losses for the surveillance (96-07).
On March 31,1996 between 1630 hours0.0189 days <br />0.453 hours <br />0.0027 weeks <br />6.20215e-4 months <br /> and 1800 hours0.0208 days <br />0.5 hours <br />0.00298 weeks <br />6.849e-4 months <br /> power was reduced to remove 6C Feedwater Heater from senice for maintenance. This resulted in 39.1 MWHRS of unplanned losses. (96-09) j As of March 31,1996 the unit had been on-line for seven days.
1 i
l l
1 i
I
\\
l l
i i
l l
l DOCKET NO.: 50-354 UNIT: Hope Creek DATE: 4/10/96 COMPLETED BY:
D. W. Lyons TELEPHONE: (609) 339-3517 I
l
SUMMARY
OF CHANGES, TESTS, AND EXPERIMENTS FOR THE HOPE CREEK GENERATING STATION MONTH MARCH 1996 i
There will be no summaries of changes to the plant submitted this month. Starting with next month's report, summaries of changes will be reported with a one month delay (e.g.
Changes made in March 1996 will be reported with the April operating data.)
i