- ML20247K012 + (ML20247K012)
- ML20247K013 + (ML20247K013)
- ML20247K016 + (ML20247K016)
- ML20247K017 + (ML20247K017)
- ML20247K018 + (ML20247K018)
- ML20247K019 + (ML20247K019)
- 05000373/LER-1989-009-01, :on 890302,phase to Ground Fault Resulted in Generator Isolation.Caused by Failure Phase C Lightning Arrestor on Primary of Side of Station Auxiliary Transformer + (ML20247K020)
- ML20247K021 + (ML20247K021)
- ML20247K022 + (ML20247K022)
- IR 05000458/1989027 + (ML20247K025)
- ML20247K026 + (ML20247K026)
- ML20247K027 + (ML20247K027)
- 05000364/LER-1989-005, :on 890429,ESF Actuation Occurred When Safety Injection Signal Generated After Train a Solid State Selector Switch Placed in Operate Mode.Caused by Personnel Error.Disciplinary Action Administered + (ML20247K029)
- ML20247K030 + (ML20247K030)
- 05000352/LER-1989-008, :on 890126,various Plant Sys Inoperable Due to Deficiencies in Physical Separation Between Class 1E & non-Class 1E Cables & Different ESF Divs.Caused by Inadequate Procurement Spec.Panels Deenergized + (ML20247K031)
- ML20247K032 + (ML20247K032)
- ML20247K033 + (ML20247K033)
- ML20247K034 + (ML20247K034)
- 05000458/LER-1989-011, :on 890321,leak Rate Test Results of Each Penetration Was in Excess of 2.4 Std Cubic Ft Per Minute. Caused by Corrosion Products Preventing Full Closure of Valves.Maint Work Orders Issued + (ML20247K035)
- 05000271/LER-1989-016, :on 890330,automatic Start of Core Spray & Sys a RHR Pumps Occurred While Pressurizing Primary Containment.Caused by Inadequate Procedure.Design Change That Implemented Logic Change Reviewed + (ML20247K037)
- ML20247K040 + (ML20247K040)
- 05000368/LER-1989-007, :on 890424,snubber on Valve (2CV-4653) on Pressurizer Spray Line Found Disconnected While Performing Inservice Insp of Mechanical Snubbers.Caused by Inadequate Work Controls.Snubber on 2CV-4653 Replaced + (ML20247K041)
- ML20247K044 + (ML20247K044)
- ML20247K046 + (ML20247K046)
- ML20247K047 + (ML20247K047)
- ML20247K050 + (ML20247K050)
- ML20247K053 + (ML20247K053)
- ML20247K054 + (ML20247K054)
- PNO-I-89-061, on 890704,therapeutic Misadministration Occurred When Wrong Patient Administered 250 Rads Co-60 to Lumbar/Sacral Spine Instead of Lung.Patient Identification Strengthened by Using Photographs + (ML20247K057)
- 0CAN059804, Forwards Rev 37 to Industrial Security Plan,Per 10CFR50.54(p).Summary of Changes Described in Attachment.Rev Withheld + (ML20247K058)
- ML20247K060 + (ML20247K060)
- 05000414/LER-1989-016, :on 890616,both Channels of Upper Range Reactor Vessel Level Instrumentation Found Inoperable.Caused by Supervision Assigning Unqualified Technician to Return Instrumentation to Svc on 890528 + (ML20247K061)
- ML20247K062 + (ML20247K062)
- ML20247K065 + (ML20247K065)
- ML20247K067 + (ML20247K067)
- 05000409/LER-1989-001, :on 890424,discovered That Weekly Battery Tests for Previous Wk Had Not Been Performed.Caused by Absences of Key Personnel Who Supervise & Perform Tests.Required Testing Procedures Performed + (ML20247K071)
- ML20247K072 + (ML20247K072)
- IR 05000482/1989023 + (ML20247K073)
- ML20247K075 + (ML20247K075)
- ML20247K077 + (ML20247K077)
- ML20247K080 + (ML20247K080)
- ML20247K082 + (ML20247K082)
- ML20247K084 + (ML20247K084)
- ML20247K086 + (ML20247K086)
- ML20247K090 + (ML20247K090)
- PNO-II-89-064, on 890907,plant Shut Down for More than 48 H to Determine Cause of Out of Spec Secondary Chemistry.Msiv a Test Circuitry Discovered Energized & Valve Declared Inoperable on 890908.Caused by Water Hammer in Flush Line + (ML20247K092)
- PNO-II-89-063A, on 890906,Augmented Insp Team Dispatched to Investigate Overpressurization of Containment Spray Sys & Resultant Spill of Contaminated Water Into Auxiliary Bldg. Problems Existed W/Operability Test Procedure + (ML20247K095)
- ML20247K096 + (ML20247K096)
- ML20247K097 + (ML20247K097)
- ML20247K098 + (ML20247K098)
- ML20247K101 + (ML20247K101)