Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20154G145 + (ML20154G145)
- TXX-8840, Forwards Updated S&W Corrective Action Program Design Validation Package Indexes for Civil/Structural,Mechanical, Electrical,Instrumentation & Control & Nutech Mechanical Procurement Status Rept Units + (ML20154G147)
- ML20154G148 + (ML20154G148)
- ML20154G149 + (ML20154G149)
- IR 05000443/1998007 + (ML20154G150)
- 05000280/LER-1986-009, :on 860208,during Startup,Operating Main Feedwater Pump Tripped Due to High Level in Steam Generator C.Caused by Dust Accumulation in Pilot Relay Blocking Air to Valve Operator.Blockage Removed + (ML20154G151)
- ML20154G153 + (ML20154G153)
- ML20154G157 + (ML20154G157)
- ML20154G160 + (ML20154G160)
- ML20154G161 + (ML20154G161)
- 05000498/LER-1988-048, :on 880816,reactor Tripped as Result of Main Turbine Trip.Caused by Failure of Stator Cooling Water Pump Discharge Check Valve to Close.Stator Cooling Water Pump Discharge Check Valve Packing Replaced + (ML20154G162)
- ML20154G163 + (ML20154G163)
- ML20154G166 + (ML20154G166)
- ML20154G168 + (ML20154G168)
- ML20154G169 + (ML20154G169)
- ML20154G172 + (ML20154G172)
- ML20154G173 + (ML20154G173)
- ML20154G174 + (ML20154G174)
- ML20154G175 + (ML20154G175)
- 05000456/LER-1998-003, Forwards LER 98-003-00 from Braidwood Generating Station,Iaw 10CFR50.73(a)(2)(iv).Listed Commitments Made in LER + (ML20154G176)
- ML20154G182 + (ML20154G182)
- ML20154G184 + (ML20154G184)
- ML20154G186 + (ML20154G186)
- ML20154G187 + (ML20154G187)
- ML20154G188 + (ML20154G188)
- ML20154G189 + (ML20154G189)
- IR 05000498/1988023 + (ML20154G190)
- ML20154G191 + (ML20154G191)
- JAFP-98-0319, Informs That Authority Is Revising Commitment Re Surveillance on Locked Valves at Ja Fitzpatrick Nuclear Power Plant.Changes to Commitments Listed + (ML20154G193)
- ML20154G196 + (ML20154G196)
- BECO-88-133, Forwards Response to NRC Bulletin 88-05 & Suppls 1 & 2, Nonconforming Matls, Supplied by Piping Supplies,Inc at Folsom,Nj & West Jersey Mfg Co at Williamstown,Nj + (ML20154G197)
- ML20154G200 + (ML20154G200)
- ML20154G203 + (ML20154G203)
- ST-HL-AE-2655, Summarizes Results of Eddy Current Insp of Bottom Mounted Instrumentation Thimbles,Short & long-term Corrective Action & How Results Compare to European Data & Action Plan + (ML20154G205)
- 05000352/LER-1988-015, :on 880418,emergency Diesel Generator auto-started Due to Unplanned Test Start Signal.Caused by Personnel Error.Training Memo Issued to All Field Engineers Requiring Completion of Stated Form + (ML20154G207)
- ML20154G208 + (ML20154G208)
- ML20154G209 + (ML20154G209)
- ML20154G211 + (ML20154G211)
- ML20154G214 + (ML20154G214)
- ML20154G216 + (ML20154G216)
- ML20154G219 + (ML20154G219)
- ML20154G226 + (ML20154G226)
- 05000280/LER-1986-002, :on 860108,unit Tripped from 97% Power & Specific Activity Sample of Reactor Coolant Exceeded Tech Spec Dose Equivalent I-131 Limit.Caused by Iodine Spike. Level Monitored Every 4 H + (ML20154G228)
- 05000456/LER-1998-003-07, :on 980906,loss of Offsite Power Event Was Experienced Due to Electrical Fault.Caused by Matl Dislodged by High Winds.Maint Contract Specifications Will Be Revised to Establish Requirements for Housekeeping + (ML20154G231)
- ML20154G232 + (ML20154G232)
- 05000424/LER-1988-021, :on 880712,discovered That Procedure for Performing Surveillance Re Tech Spec Resistance Values of 125 Volt Dc Battery Sys Inadequate.Caused by Inadequate Procedure.Procedure Revised + (ML20154G233)
- ML20154G236 + (ML20154G236)
- ML20154G238 + (ML20154G238)
- 05000382/LER-1997-032-01, Forwards LER 97-032-01,re Details of Noncompliance with Plant TS Due to Failure to Meet GDC 54,per 10CFR50.73 (a)(2)(i)(B) + (ML20154G239)
- 05000352/LER-1986-006-01, :on 860122,failure to Perform Tech Spec Surveillance Requirements Discovered.Caused by Inadequate Communication of Surveillance Test Due Dates.Administrative Guideline Implemented + (ML20154G242)
- ML20154G243 + (ML20154G243)