- ML20134G734 + (ML20134G734)
- L-96-296, LER 96-S02-00:on 961011,failed to Terminate Access of Temporary Licensee Employee.Caused by Cognitive Personnel Error.Security Unassigned Card Key & Plant Administrative Procedure 0010509 Revised + (ML20134G736)
- 05000255/LER-1985-008, :on 850723,plant Shutdown Occurred Due to Inoperable Control Room Emergency Air Cleanup Sys.Caused by Removal of Exhaust Fan Ducting Leading to Unisolable Path to External Environ.Drawings Review Planned + (ML20134G739)
- ML20134G740 + (ML20134G740)
- IA-96-394, Final Response to FOIA Request for Documents.Forwards Apps a & B Documents.Documents Also Available in Pdr.App B Documents Partially Withheld (Ref FOIA Exemptions 3 & 4) + (ML20134G740)
- ML20134G742 + (ML20134G742)
- ML20134G743 + (ML20134G743)
- 05000409/LER-1985-015, :on 850726,scram Occurred from Approx 0.06% Power.Caused by Indicated Flux Spike When Range Switch on Nuclear Instrumentation Channel 5 Was Upscaled.Range Switch Contacts Cleaned.Switch Elimination Planned + (ML20134G744)
- ML20134G745 + (ML20134G745)
- ML20134G749 + (ML20134G749)
- ML20134G750 + (ML20134G750)
- ML20134G752 + (ML20134G752)
- ML20134G753 + (ML20134G753)
- RBG-21824, Forwards Rev to FSAR Resolving Recently Identified Inconsistency Re Structural Welding Code Requirements.Rev Will Be Included in Future FSAR Amend.No Changes to Tech Specs Required + (ML20134G754)
- ML20134G755 + (ML20134G755)
- ML20134G756 + (ML20134G756)
- ML20134G757 + (ML20134G757)
- ML20134G758 + (ML20134G758)
- NSD-NRC-96-4881, Responds to RAI Re AP600 Design Certification Program + (ML20134G760)
- 05000296/LER-1985-020-01, :on 850721,walkdown of Core Spray Sys Revealed Missing Pipe Support.Caused by Engineer Error.Line Seismically Qualified Except for LOCA-induced Torus Hydrodynamic Loads.Hanger to Be Installed + (ML20134G761)
- ML20134G762 + (ML20134G762)
- ML20134G763 + (ML20134G763)
- IA-96-428, Final Response to FOIA Request for Documents.Forwards App a Document.Documents Also Available in PDR + (ML20134G763)
- ML20134G764 + (ML20134G764)
- ML20134G765 + (ML20134G765)
- ML20134G766 + (ML20134G766)
- NSD-NRC-96-4878, Discusses 960813-14 Meeting Which Described Power Supply to AP600 H Igniters + (ML20134G769)
- ML20134G771 + (ML20134G771)
- ML20134G774 + (ML20134G774)
- ML20134G777 + (ML20134G777)
- RBG-21903, Interim Deficiency Rept DR-314 Re Leakage of Fluid Fyrquel from Pump Seals to Pump Drive Motor in Borg-Warner Electrohydraulic Operators for Copes-Vulcan Modulating Valves.Next Rept Will Be Submitted by 850906 + (ML20134G778)
- ML20134G780 + (ML20134G780)
- ML20134G782 + (ML20134G782)
- 3F0785-30, Suppl 1 to Special Rept 85-02:Halon Portion of Fire Suppression Sys Inoperable.Addl Work Required Due to Unanticipated Difficulties W/Asbestos Matls in Areas Being Modified.Operability Not Restored by 850701 + (ML20134G783)
- ML20134G784 + (ML20134G784)
- IA-96-393, Final Response to FOIA Request for Records.Forwards App a Records.Documents Also Available in PDR + (ML20134G784)
- 05000321/LER-1985-029, :on 850806,instruments Could Not Detect or Measure Noble Gas During Monitoring Procedure.On 850815, Preplanned Alternate Method Failed to Follow Tech Specs. Caused by Design & Nonlicensed Staff Error + (ML20134G785)
- ML20134G786 + (ML20134G786)
- ML20134G788 + (ML20134G788)
- ML20134G789 + (ML20134G789)
- NSD-NRC-96-4879, Summarizes What Westinghouse Has Chosen to Do Re Updating AP600 HCLPF Values for Seismic Margins Assessment + (ML20134G790)
- ML20134G791 + (ML20134G791)
- ML20134G792 + (ML20134G792)
- ML20134G793 + (ML20134G793)
- ML20134G797 + (ML20134G797)
- 05000321/LER-1985-027, :on 850724,reactor Scram Occurred at 98% Power.Caused by Inboard MSIV a (B21-F022A) Drifting Closed Due to Improper Backseating of Msiv.Inboard MSIV a Rebuilt & Stem Replaced + (ML20134G799)