Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20134E285 + (ML20134E285)
- ML20134E286 + (ML20134E286)
- ML20134E288 + (ML20134E288)
- ML20134E289 + (ML20134E289)
- ML20134E290 + (ML20134E290)
- ML20134E292 + (ML20134E292)
- ML20134E293 + (ML20134E293)
- ML20134E294 + (ML20134E294)
- ML20134E295 + (ML20134E295)
- ML20134E296 + (ML20134E296)
- 05000281/LER-1984-021, :on 841216,trip Occurred When Breakers for Main Feed Pump B Opened.Caused by Excessive Drift in Pressure That Input Low Flow Signals to Recirculation Valve/Pump Trip Logic.Procedures Modified + (ML20134E299)
- ML20134E300 + (ML20134E300)
- ML20134E301 + (ML20134E301)
- B15951, Provides Comments on Preliminary Accident Sequence Precursor (ASP) Program Analysis of Operational Events & Conditions Occurred at Plant.Calculation Encl + (ML20134E304)
- IR 05000245/1985011 + (ML20134E306)
- ML20134E307 + (ML20134E307)
- ML20134E308 + (ML20134E308)
- W3P85-1462, Forwards Kw Cook Affidavits Requesting That Info Received from Shell Oil & Chemical Co & Transportation Ltrs of Agreement Be Withheld.Affidavits Resubmitted Per Conversations W/J Wilson + (ML20134E309)
- ML20134E310 + (ML20134E310)
- ML20134E311 + (ML20134E311)
- 05000361/LER-1996-008, :on 960926,RCP Lube Oil Collection Sys Sightglass & Mounting Extended Slightly Beyond Lateral Limits of Oil Collection Sys Drain Pan,Resulting in Leaking Oil Outside Sys.Cause Under Investigation + (ML20134E312)
- ML20134E313 + (ML20134E313)
- 05000373/LER-1985-054-01, :on 850718,process Radiation Monitors Registered off-scale High,Actuating Control Room Emergency Makeup Filter Train B.Caused by Defective Procedure. Procedure Revised & Submitted for Approval + (ML20134E317)
- ML20134E319 + (ML20134E319)
- PNO-I-85-058, on 850813,reactor Tripped & Main Steam Line Isolation Occurred Due to Indicated Steam Line Area High Radiation.Caused by Air Introduction Into Feedwater Sys While Placing Demineralizer in Svc + (ML20134E320)
- ML20134E321 + (ML20134E321)
- ML20134E322 + (ML20134E322)
- ML20134E323 + (ML20134E323)
- ML20134E325 + (ML20134E325)
- ML20134E326 + (ML20134E326)
- ML20134E329 + (ML20134E329)
- 05000482/LER-1985-052, :on 850712,control Room Ventilation Isolation Signal Initiated Due to Alarm on Control Room HVAC Chlorine Monitor.Caused by Broken Filter Paper Tape.Tape Replaced + (ML20134E333)
- ML20134E334 + (ML20134E334)
- ML20134E335 + (ML20134E335)
- ML20134E336 + (ML20134E336)
- ML20134E337 + (ML20134E337)
- ML20134E339 + (ML20134E339)
- ML20134E340 + (ML20134E340)
- 05000259/LER-1985-037, :on 850718,during Refueling Outage,Inadevertent Containment Isolation Occurred When Wire Pinched & Shorted to Ground.Caused by Defective Relay.Relay Replaced + (ML20134E341)
- ML20134E343 + (ML20134E343)
- ML20134E344 + (ML20134E344)
- ML20134E345 + (ML20134E345)
- ML20134E348 + (ML20134E348)
- ML20134E350 + (ML20134E350)
- IA-96-513, Responds to FOIA Request for Documents.Forwards App a Records Being Made Available in Pdr.App B Records Being Withheld in Entirety (Ref Exemption 3) + (ML20134E350)
- 05000322/LER-1985-026, :on 850713,during Surveillance Leak Test of Primary Containment Personnel Hatch,Leakage Rate Found in Excess of Tech Spec Limit.Caused by Weak Seating of Manual Valve to Door Interlock Pressure Switch + (ML20134E351)
- ML20134E352 + (ML20134E352)
- ML20134E353 + (ML20134E353)
- ML20134E355 + (ML20134E355)
- ML20134E356 + (ML20134E356)
- IR 05000528/1985022 + (ML20134E357)