Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20112C345 + (ML20112C345)
- 05000364/LER-1996-002, :on 960422,discovered Misapplication of TS 4.4.6 Requirements Re F*.Caused by Inadequate Surveillance Test Procedure.Surveillance Test Procedure Will Be Revised + (ML20112C351)
- ML20112C355 + (ML20112C355)
- ML20112C356 + (ML20112C356)
- ML20112C394 + (ML20112C394)
- ML20112C400 + (ML20112C400)
- ML20112C401 + (ML20112C401)
- ML20112C407 + (ML20112C407)
- ML20112C409 + (ML20112C409)
- ML20112C425 + (ML20112C425)
- ML20112C430 + (ML20112C430)
- 05000237/LER-1984-024-05, :on 841207,secondary Containment Momentarily Broken When Turbine Bldg Interlock Door Opened Before Reactor Bldg Interlock Door Fully Closed.Caused by Personnel Exiting Reactor Bldg.Door Functioning Properly + (ML20112C436)
- ML20112C439 + (ML20112C439)
- 05000237/LER-1984-019-06, :on 841206,w/unit in Refuel & Inservice Insp in Progress,Welds Located in Reactor Water Cleanup Sys Identified as Having Rejectable Indications.Repairs Will Be Made by Weld Overlay &/Or Pipe Replacement + (ML20112C446)
- 05000413/LER-1984-029-02, :on 841206,Westinghouse Notified Util of Insp Results Re CRD Mechanism Design.During 841215 Insp of All Unit 1 Drive rods,14 Unacceptable Drive Rods Found.Rods Replaced & Returned to Westinghouse + (ML20112C452)
- ML20112C473 + (ML20112C473)
- ML20112C482 + (ML20112C482)
- 05000321/LER-1984-012, :on 841114,20 & 1206,reactor Protection Sys Logic Actuation Occurred for No Apparent Reason.Caused by Blown Fuse & Lifted Wire.Fuse in Panel 1H11-P610 & Wire Replaced + (ML20112C484)
- ML20112C489 + (ML20112C489)
- PLA-2403, Revises Expected Completion Date for Resolution of NUREG-0737,Item II.F.1 Until 851231 Due to Complexity of Problem + (ML20112C506)
- ML20112C517 + (ML20112C517)
- ML20112C529 + (ML20112C529)
- ML20112C531 + (ML20112C531)
- ML20112C534 + (ML20112C534)
- ML20112C537 + (ML20112C537)
- ML20112C547 + (ML20112C547)
- ML20112C548 + (ML20112C548)
- ML20112C549 + (ML20112C549)
- ML20112C552 + (ML20112C552)
- ML20112C554 + (ML20112C554)
- ML20112C560 + (ML20112C560)
- ML20112C563 + (ML20112C563)
- ML20112C575 + (ML20112C575)
- ML20112C584 + (ML20112C584)
- ML20112C587 + (ML20112C587)
- ML20112C594 + (ML20112C594)
- ML20112C603 + (ML20112C603)
- ML20112C612 + (ML20112C612)
- ML20112C613 + (ML20112C613)
- ML20112C622 + (ML20112C622)
- ML20112C632 + (ML20112C632)
- 2CAN018501, Forwards Arkansas Nuclear One-Unit 2 Gap Insp Plan for Fourth Refueling Outage, Per .Preliminary Results of Exam Will Be Verbally Relayed Prior to Replacing Reactor Vessel Head + (ML20112C640)
- ML20112C647 + (ML20112C647)
- ML20112C648 + (ML20112C648)
- ML20112C649 + (ML20112C649)
- 05000293/LER-1985-003, :on 850210,reactor Shut Down.Caused by Oil Leak in Recirculation Pump Which Resulted in Bearing Damage.Oil Leak Repaired & Damaged Components Replaced + (ML20112C658)
- 05000412/LER-1996-002-01, :on 960220,containment Penetration Not Isolated within Time Limit.Caused by Breakdown in Administrative Controls Governing Document Updates During Initial Plant Const in 1985.Manual Isolation Valves Shut + (ML20112C702)
- 05000346/LER-1984-019, :on 841108,blank Flange Found on Outlet of Component Cooling Water Surge Tank Relief Valve CC3602.On 841130,util Determined Tank Not Protected Against Overpressurization W/Blank Flange + (ML20112C704)
- 05000321/LER-1981-052-03, /03X-1:on 810621,LPCI Inverter B R44-S003 Tripped, Resulting in Loss of Power to Suction & Discharge Valves & LPCI Injection Valve.Caused by Defective Thermal Temp Switch in Inverter Leg.Switch Replaced + (ML20112C709)
- ML20112C720 + (ML20112C720)
- AECM-85-0091, Forwards Test Rept MPL-06-221, in Situ Operational Testing of HPCS Svc Water Pump for Grand Gulf Nuclear Power Station, Per 850306 Telcon Request + (ML20112C724)