- ML20099H994 + (ML20099H994)
- ML20099J001 + (ML20099J001)
- ML20099J008 + (ML20099J008)
- ML20099J015 + (ML20099J015)
- ML20099J016 + (ML20099J016)
- RBG-19404, Interim Deficiency Rept DR-177 Re Design,Mfg & Installation of Coaxial & Instrumentation Cable to Meet Requirements of GE Neutron Monitoring Sys.Damaged Cables Replaced. Next Rept Will Be Provided by 841221 + (ML20099J024)
- ML20099J026 + (ML20099J026)
- ML20099J028 + (ML20099J028)
- ML20099J030 + (ML20099J030)
- ML20099J035 + (ML20099J035)
- ML20099J045 + (ML20099J045)
- 05000413/LER-1984-016-01, :on 841018,while in Cold Shutdown,Power Interrupted to Vent Sampling Pump.Caused by Tripped Circuit Breaker That Supplies Power to Pump Electrical Outlet. Circuit Breaker Reclosed + (ML20099J052)
- ML20099J053 + (ML20099J053)
- ML20099J054 + (ML20099J054)
- ML20099J060 + (ML20099J060)
- ML20099J062 + (ML20099J062)
- ML20099J067 + (ML20099J067)
- ML20099J069 + (ML20099J069)
- ML20099J072 + (ML20099J072)
- ML20099J079 + (ML20099J079)
- ML20099J088 + (ML20099J088)
- ML20099J095 + (ML20099J095)
- ML20099J098 + (ML20099J098)
- ML20099J099 + (ML20099J099)
- RBG-19405, Final Deficiency Rept DR-202 Re Active Thrust Bearings in Turbochargers for Standby Diesel Generators Supplied by Tdi.N&D 6258 & 6259 Generated & Dispositioned for Rework by Replacing Identical Parts + (ML20099J100)
- ML20099J106 + (ML20099J106)
- ML20099J109 + (ML20099J109)
- ML20099J113 + (ML20099J113)
- ML20099J115 + (ML20099J115)
- ML20099J119 + (ML20099J119)
- ML20099J122 + (ML20099J122)
- ML20099J127 + (ML20099J127)
- ML20099J129 + (ML20099J129)
- ML20099J131 + (ML20099J131)
- ML20099J137 + (ML20099J137)
- ML20099J140 + (ML20099J140)
- ML20099J147 + (ML20099J147)
- ML20099J150 + (ML20099J150)
- ML20099J155 + (ML20099J155)
- ML20099J156 + (ML20099J156)
- ML20099J166 + (ML20099J166)
- ML20099J168 + (ML20099J168)
- ML20099J171 + (ML20099J171)
- ML20099J179 + (ML20099J179)
- 2CAN089205, Responds to Violations Noted in Insp Rept 50-368/92-09 on 920510-0620.Corrective Actions:Temporary Mod 92-2-013 Installed on 920619,making Diverse Emergency Feedwater Actuation Sys Operable + (ML20099J182)
- RBG-19411, Interim Deficiency Rept DR-151 Re Partial Penetration Welds for Square groove,butt-welded,HVAC Ductwork.Next Rept Will Be Provided by 841219 + (ML20099J190)
- ML20099J203 + (ML20099J203)
- ML20099J204 + (ML20099J204)
- 05000387/LER-1984-046, :on 840822,QC Inspector Found Open Penetration in Ceiling of Lower Cable Spreading Room.Caused by Fire Barrier Not Being Included in Surveillance Procedure. Procedure Revised + (ML20099J206)
- ML20099J208 + (ML20099J208)
- 05000317/LER-1984-014, :on 841024,during Surveillance Testing on Battery 21,individual Cell Voltage for Cell 1 Below Tech Spec Limits.Caused Not Stated.Cell Replaced & Battery 21 Returned to Svc + (ML20099J210)