ML20099J028

From kanterella
Jump to navigation Jump to search
Interim Part 21 Rept Re Potential Problem W/Check Valve.Util Performed Only Visual Exam of Valve Disks.Name Plates of Valves Will Show Company Names Cloy Corp & Williams-Hager Co
ML20099J028
Person / Time
Site: Grand Gulf  Entergy icon.png
Issue date: 03/14/1985
From: Boyer R
TRANSAMERICA DELAVAL, INC.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
References
REF-PT21-85-137-000 PT21-85-137, PT21-85-137-000, NUDOCS 8503190573
Download: ML20099J028 (1)


Text

_

Transamanca l'*;;"l"l'1,;;"r;','o",b, ion gglgggl 550 85th Avenue P.o. Bo 2161 g oakland, Calito,nia 94621 (415) 577 7400 1

March 14, 1985 Director, Office of Inspection & Enforement U.S. Nuclear Regulatory Conmission Washington, D.C. 20555

Dear Sir:

Please refer to my letter of March 12, 1985 which described a potential problem with a Check Valve in accordance with 10CFR21.

I would like to correct a statommt I made in the last sentence of the third paragraph. Grand gulf did not perform an LPI inspection of the Valve Disk. The 2 which I stated were ok were visually ex-amined only.

In the fourth paragraph I stated the Valves were supplied by the Williams Gauge Co. (Williams-llager) of Pittsburgh. The Williams Gaugo Co. was purchased by the Cloy Corporations of Oskaloosa, Iowa and the nameplates of the Valves will show Cloy Corporations as well as Williams-Itager.

We will send copies of this letter to all the Sites listed in paragraph 2 of the March 12, 1985 letter as indicated in the cc's.

Very truly yours, 0p R. E. Boyer Kinager, Quality Assurance REBihw 0503190573 050314 PDH ADOCK 05000416 B PDR p I