Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20096G669 + (ML20096G669)
- 05000271/LER-1992-005, :on 920306,Group 1 Primary Containment Isolation & Plant Scram Occurred.Caused by Failure of Contacts on Reactor Mode Switch to Fully Close.Switch Taken to Refuel & Scram & Isolation Reset + (ML20096G670)
- JPN-92-021, Forwards Application for Amend to License DPR-59,changing TS Table 4.2-1, Min Test & Calibr Frequency for PCIS to Reflect Plant Mod to Deactivate Reactor Vessel Head Spray Portion of RHR Sys + (ML20096G672)
- ML20096G676 + (ML20096G676)
- 05000482/LER-1992-009, :on 920417,failure of Humidity Sensors Resulted in Inoperability of Both Trains of Crevs.Caused by Normal Wear of Sensors.Sensors Will Be Replaced Every 36 Months & Procedure Inc L-1000 Conducted Every 18 Months + (ML20096G677)
- ML20096G678 + (ML20096G678)
- ML20096G679 + (ML20096G679)
- ML20096G690 + (ML20096G690)
- ML20096G691 + (ML20096G691)
- ML20096G692 + (ML20096G692)
- ML20096G693 + (ML20096G693)
- ML20096G695 + (ML20096G695)
- ML20096G701 + (ML20096G701)
- ML20096G709 + (ML20096G709)
- ML20096G710 + (ML20096G710)
- ML20096G711 + (ML20096G711)
- ML20096G715 + (ML20096G715)
- ML20096G720 + (ML20096G720)
- ML20096G721 + (ML20096G721)
- ML20096G726 + (ML20096G726)
- 05000440/LER-1992-009, :on 920424 & 25,discovered That HVAC Sys Operated in Normal Instead of Isolation Mode of Operation W/ Control Room Airborne Operators Inoperable.Caused by Personnel Error.Operators Trained + (ML20096G731)
- 05000321/LER-1992-010, :on 920423,output Breakers for RPS Motor Generator Set Tripped,Causing Loss of Power to B Side of RPS & Process Radiation Monitors.Caused by Failure of Coil in Motor Starter.Starter Replaced + (ML20096G738)
- ML20096G748 + (ML20096G748)
- ML20096G752 + (ML20096G752)
- ML20096G758 + (ML20096G758)
- ML20096G760 + (ML20096G760)
- 05000361/LER-1992-008-01, :on 920424,automatic Turbine Trip/Reactor Trip Occurred.Caused by Failure of Transformer 2B13X.Transformer Was Replaced + (ML20096G763)
- NRC-92-0068, Confirms Util Commitment on Procedure to Ensure That Each Containment Isolation Valve Will Be in Appropriate Position During SBO Event & Provides Schedule for Final Implementation of Procedure + (ML20096G767)
- ML20096G768 + (ML20096G768)
- ML20096G772 + (ML20096G772)
- ML20096G773 + (ML20096G773)
- ML20096G775 + (ML20096G775)
- ML20096G784 + (ML20096G784)
- ML20096G786 + (ML20096G786)
- ML20096G788 + (ML20096G788)
- ML20096G793 + (ML20096G793)
- ML20096G794 + (ML20096G794)
- ML20096G796 + (ML20096G796)
- ML20096G798 + (ML20096G798)
- ML20096G799 + (ML20096G799)
- ML20096G802 + (ML20096G802)
- ML20096G804 + (ML20096G804)
- ML20096G805 + (ML20096G805)
- ML20096G811 + (ML20096G811)
- ML20096G814 + (ML20096G814)
- ML20096G818 + (ML20096G818)
- ML20096G820 + (ML20096G820)
- ML20096G824 + (ML20096G824)
- ML20096G829 + (ML20096G829)
- ML20096G836 + (ML20096G836)
- ML20096G837 + (ML20096G837)