- 05000327/LER-1984-048, :on 840725,during Review of Instrumentation Drawings,Only One RCS Pressure Channel Found Existent in Field Where Two Are Required.Previous Design Change Dictated Moving Channel.Second Channel Installed + (ML20096A288)
- ML20096A289 + (ML20096A289)
- 05000374/LER-1984-042-01, :on 840728,rod Sequence Control Sys Declared Inoperable & Reactor Manually Scrammed.Primary Containment Isolation Sys Group I Isolation Also Occurred.Caused by Failure of Pressure Transmitter & Vacuum + (ML20096A293)
- ML20096A295 + (ML20096A295)
- 05000255/LER-1984-014, :on 840728,w/reactor Critical in Hot Standby Condition,Primary Coolant Temp Dropped Below 525 F.Caused by Personnel Error.Procedure Revised + (ML20096A297)
- ML20096A299 + (ML20096A299)
- ML20096A300 + (ML20096A300)
- 05000255/LER-1984-013, :on 840727,results of Daily Leak Rate Calculation Indicated Unidentified Primary Coolant Sys Leakage Greater than 1 Gpm.Caused by Charging Pump Seal Leak.Pump Repaired & Procedures Revised + (ML20096A301)
- 05000237/LER-1984-008, :on 840530,during Fire Protection Tech Spec Audit,Lack of Cardox Sys Master Valve Test in Automatic Mode Noted.Surveillance Procedure Revised to Test Valve in Both Manual & Automatic Modes + (ML20096A304)
- ELV-03708, Comment on Draft NUREG-1449, Shutdown & Low-Power Operation at Commercial Nuclear Power Plants in Us. Informs That Licensee Believes BWROG Comments to Be Appropriate & Beneficial + (ML20096A307)
- 05000237/LER-1984-006, :on 840208,east LPCI Corner Room Submarine Door to Torus Basement Open & Unattended.Caused by Personnel Error.Personnel Retrained + (ML20096A314)
- 05000249/LER-1984-008-06, :on 840804,while Opening Valve 1601-58,drywell to Torus Differential Pressure Fell Below Tech Spec Level. Caused by Closed Pressure Control Valve 8599-538.Personnel Counseled + (ML20096A318)
- ML20096A330 + (ML20096A330)
- ML20096A340 + (ML20096A340)
- B14121, Application for Amend to License NPF-49,revising TS 4.7.10.b to Delete Phrase and the First Insp Interval Determined Using This Criterion Shall Be Based Upon Previous Insp as Established by Requirements in Effect Before Amend 62 + (ML20096A341)
- ML20096A353 + (ML20096A353)
- ML20096A355 + (ML20096A355)
- ML20096A356 + (ML20096A356)
- ML20096A360 + (ML20096A360)
- RBG-18702, Interim Deficiency Rept DR-223 Re Installation of Mechanical Snubbers Supplied by Pacific Scientific.Next Rept Will Be Provided by 841026 + (ML20096A376)
- ML20096A385 + (ML20096A385)
- ML20096A386 + (ML20096A386)
- FVY-84-105, Requests Extension of Schedule for Implementation of Upgraded Emergency Operating Procedures Until 850601,due to Need to Complete Operator Training on Procedures,Per Suppl 1 to NUREG-0737 + (ML20096A394)
- ML20096A395 + (ML20096A395)
- ML20096A396 + (ML20096A396)
- ML20096A398 + (ML20096A398)
- ML20096A401 + (ML20096A401)
- ML20096A402 + (ML20096A402)
- ML20096A403 + (ML20096A403)
- ML20096A409 + (ML20096A409)
- ML20096A413 + (ML20096A413)
- ML20096A426 + (ML20096A426)
- ML20096A430 + (ML20096A430)
- ML20096A443 + (ML20096A443)
- PY-CEI-NRR-1487, Forwards Rev 1 to Facility ERDS Data Point Library Ref File, Per 920408 & 22 Telcon RAIs + (ML20096A444)
- PLA-2276, Responds to Request for Addl Info Re IE Bulletin 83-07, Apparently Fraudulent Products Sold by Ray Miller,Inc. Fraudulent Practices by Matl Suppliers Will Not Adversely Affect Safe Rigorous QA Program + (ML20096A445)
- ML20096A454 + (ML20096A454)
- ML20096A458 + (ML20096A458)
- ML20096A465 + (ML20096A465)
- ML20096A485 + (ML20096A485)
- ML20096A491 + (ML20096A491)
- 05000275/LER-1984-022, :on 840728,safety Injection & Reactor Trip Occurred Due to lo-lo T Average & High Steam Flow Signals. Caused by Personnel Not Considering Effect of Low RCS Signal on Safety Injection Actuation Logic + (ML20096A498)
- ML20096A504 + (ML20096A504)
- ML20096A507 + (ML20096A507)
- ML20096A509 + (ML20096A509)
- ML20096A512 + (ML20096A512)
- ML20096A514 + (ML20096A514)
- ML20096A518 + (ML20096A518)
- CY-84-024, FOIA Request That SECY-84-29 & Encl of Pl William Re Functional Description of Safety Parameter Display Sys Be Placed in PDR + (ML20096A528)
- ML20096A529 + (ML20096A529)
- ML20096A531 + (ML20096A531)