- ML20095D620 + (ML20095D620)
- ML20095D621 + (ML20095D621)
- ML20095D624 + (ML20095D624)
- ML20095D626 + (ML20095D626)
- ML20095D627 + (ML20095D627)
- ML20095D628 + (ML20095D628)
- CY-86-037, FOIA Request for IE Manual Chapter 2955 as Ref on Page 2 of Attached SECY-86-37,draft NRC Manual Chapter 0516 as Ref in from NRC to NSP & NRC Manual Chapter 0516 as Ref in NRR Ofc Ltr 44,Rev 1 + (ML20095D649)
- 05000302/LER-1984-016, :on 840720,quality Programs Audit Determined That Alarm/Trip Setpoint for Fuel Storage Pool Area Gaseous Activity Process Monitor RM-A4 Exceeded Tech Spec Limit. Caused by Not Following Action Requirements + (ML20095D653)
- 05000483/LER-1984-021, :on 840719,Train a of Ssps Found in Inhibit Mode W/Train B in Test.Train B Returned to Normal. Surveillance Procedure Changed + (ML20095D655)
- ML20095D659 + (ML20095D659)
- ML20095D661 + (ML20095D661)
- 05000302/LER-1984-016-01, :on 840720,quality Programs Audit Determined That Alarm/Trip Setpoint for Fuel Storage Pool Area Gaseous Activity Process Monitor RM-A4 Exceeded Tech Spec Limit + (ML20095D663)
- ML20095D668 + (ML20095D668)
- ML20095D672 + (ML20095D672)
- ML20095D677 + (ML20095D677)
- ML20095D689 + (ML20095D689)
- ML20095D730 + (ML20095D730)
- ML20095D734 + (ML20095D734)
- ML20095D739 + (ML20095D739)
- ML20095D761 + (ML20095D761)
- 05000275/LER-1984-021, :on 840720,reactor Protection Sys Actuated Due to Coincidence of Steam Generator 1-3 Low Level & Steam Flow/Feed Flow Mismatch.Caused by Failed Valve Operator. Valve Operator Replaced + (ML20095D776)
- ML20095D807 + (ML20095D807)
- ML20095D815 + (ML20095D815)
- 05000254/LER-1984-014-04, :on 840808,while Starting Shutdown Cooling Mode of RHR Sys,Lpci Valves 1-1001-29A & B Would Not Open. Caused by Personnel Error.Valve Stems Removed & Being Replaced + (ML20095D817)
- 05000272/LER-1984-017-01, :on 840716,insp Revealed Metal Filings in Charging Pump Casings.Filings May Have Caused 840713 Seizure of Charging Pump 12 & Seizure of Redundant Centrifugal Charging Pump.Investigation Continuing + (ML20095D829)
- ML20095D832 + (ML20095D832)
- 05000327/LER-1984-047, :on 840717,high Radiation Signal Actuated, Causing Ventilation Isolation in Auxiliary & Containment Bldgs.Caused by Radiation Monitor Wire Slipping Onto Power Supply,Tripping Breaker.All Equipment Reset + (ML20095D852)
- ML20095D861 + (ML20095D861)
- ML20095D863 + (ML20095D863)
- 05000348/LER-1984-013, :on 840716,continuous Fire Watch Not Posted in Closed Cooling Water HX & Pump Room While Maint Personnel Performing Grinding & Welding Operations.Watch Posted & Maintained Until No Longer Required + (ML20095D864)
- ML20095D865 + (ML20095D865)
- 05000354/LER-1995-031, :on 951110,plant Shut Down Due to Inability to Perform Surveillance 4.6.2.1,drywell to Suppression Chamber Pressure Decay Test.Vacuum Breakers Will Be Tested & Testing Methodology Will Be Revised + (ML20095D867)
- 05000354/LER-1995-032, :on 951114,failed to Complete Flood Protection Actions within Required Timeframe,Resulting in TS Violation Due to Low Mgt Priority Placed on Resolving Watertight Door Problems Properly.Watertight Door Repaired + (ML20095D871)
- 05000374/LER-1984-038-01, :on 840717,Door 430 to Reactor Water Cleanup HX B Room Left Open.Security Alerted But Checked Wrong Door. Door Immediately Secured on 840718.Engineering Controls Investigated + (ML20095D889)
- ML20095D899 + (ML20095D899)
- 05000374/LER-1984-039-01, :on 840719,at 80% Power,Pressure Switches 2E31-N022A,B,C & D Found out-of-tolerance in Nonconservative Direction.Cause Not Determined.Switches Recalibr & Will Be Replaced During Environ Qualification + (ML20095D902)
- 05000271/LER-1984-011, :on 840616,while Performing Type C Leak Rate Testing,Valves MSIV-86B,CRD-412A,PCAC V16-19-8,FDW-96A & CA-89C Found W/Seat Leakage Above Tech Spec Limits.Maint Performed & Valves Retested + (ML20095D905)
- RBG-18526, Interim Deficiency Rept DR-217 Re Bolting Matls Supplied by Cardinal Industrial Products.Next Rept Will Be Submitted by 841017 + (ML20095D910)
- ML20095D914 + (ML20095D914)
- 05000483/LER-1984-018, :on 840718,fuel Bldg Isolation & Control Room Ventilation Isolation Signals Initiated from Radiation Monitoring Elements.Caused by Brief Voltage Abnormality During Bus Realignment.Design Change Requested + (ML20095D921)
- ML20095D922 + (ML20095D922)
- ML20095D935 + (ML20095D935)
- ML20095D943 + (ML20095D943)
- ML20095D951 + (ML20095D951)
- ML20095D977 + (ML20095D977)
- ML20095D980 + (ML20095D980)
- ML20095D981 + (ML20095D981)
- ML20095D982 + (ML20095D982)
- FVY-84-101, Requests Extension Until 841101 for Responding to Generic Ltr 84-15 Re Diesel Generator Reliability.Delay Due to Extensive Engineering Efforts Associated w/8-wk 1984 Refueling Outage + (ML20095D983)
- ML20095D998 + (ML20095D998)
- ML20095E001 + (ML20095E001)