Amends 96 & 77 to Licenses DPR-53 & DPR-69,respectively, Reflecting Administrative Organization Changes,Installation of Addl Fire Protection Instrumentation & Change in Control of Access to High Radiation Areas
ML20095D998
Person / Time
Site: Calvert Cliffs  
Issue date: 08/02/1984
From: John Miller
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20095D999 List:
References
NUDOCS 8408240017
Download: ML20095D998 (30)


Text

.- -

'8 UNITED STATES g'

g NUCLEAR REGULATORY COMMISSION j

WASHINGTON, D. C. 20555

i,,

e

%,...../

BALTIMORE GAS AND ELECTRIC COMPANY DOCKET NO. 50-317 CALVERT CLIFFS NUCLEAR POWER PLANT UNIT NO. 1 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 96 License No. DPR-53 1.

The Nuclear Regulatory Comission (the Comission) has found that:

A.

The application for amendment by Baltimore Gas & Electric Company (the licensee) dated April 8, 1984, complies with the stand rJs and requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Comission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance (1) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations; D.

The issuance of this amendment will not be inimical to the comon defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all applicable requirements have been satisfied.

l 8408240017 840802 DR ADOCK 05000 a

w

~

2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment ta this license amendment, and paragraph 2.C.(2) of Facility Operating License No. DPR-53 is hereby amended to read as follows:

(2) Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No. 96, are hereby incorporated in the license. The licensee shall operate l

the facility in accordance with the Technical Specifica-l tions.

3.

This license amendment is effective within 30 days of its issuance.

FOR THE NUCLEAR REGULATORY COMMISSION l

l ames R. Miller, Chief l

Operating Reactors Branch #3 Division of Licensing i

I

Attachment:

Changes to the Technical Specifications Date of Issuance:

August 2, 1984 l

l t

r

ATTACHMENT TO LICENSE AMENDMENT NO. 96 FACILTIY OPERATING LICENSE NO. DPR-53 DOCKET NO. 50-317 Replace the following pages of the Appendix "A" Technical Specifications with the enclosed pages. The revised pages are identified by Amendment number and contain vertical lines indicating the areas of change. The corresponding overleaf pages are provided to maintain document completeness.

Pages 3/4 3-45 3/4 3-46 6-2 6-3 6-21 4

e

-.-.e

.--r

.--.-,-..,,,,.m..

--y-r, y-.---

TABLE 3.3-11 FIRE DETECTION INSTRUMEETS UNIT l INSTRUMENT LOCATION MINIMUM INSTRUMENTS OPERABLE HEAT FLAMr.

SM0KE Spent Fuel Pool Heat Exchanger Room 320 3

Main Control Room 405 6

l Control Room Vent Duct "a

  • 2 Main. Plant Exhaust Equip Room 524 8

Control Room HVAC Equip Room 512 4

Passage and Filter Room 323 3

Unit 1 Cont SW Elec Pen Area

  • 4 Unit 1 Cont NE Elec Pen Area
  • 4 Unit 1 Cont East RCPS*

16 Unit 1 Cont West RCPS*

16 Control Room Vent Duct "B" 1

West Passage 319 Elev 27'-0" 6

.E/W Corridor 104,100 and 106 Eley (-) 10*-0" 5

l Intake Structure 48 Unit 1 Waste Proc Control Room 111 1

Coolant Waste Rec / Mon TK Pp Room 110 2

11 Diesel Generator **

2 12 Diesel Generator **

2 Unit 1 Cable Tunnel Elev 83'-0" 4

Cable Chase l A 1

Cable Chase 1B 1

Unit 1 C.S.R. & Cable Chase IC**

2 10 Unit 1 Personnel Access Area Room 525 3

Unit 1 Switchgdar Elev 27'-0" Room 317**

6 Unit 1 Switchgear Elev 45'-0" Room 430**

8 Unit 1 Elec Equip Room 529 3

3 Unit i East Elec Pen Room 429 Unit 1 West Elec Pen Room 423 3

Unit 1 Refueling Water TK Pump Room 439 2

Unit 1 East Piping Pen Rooms 227 and 316 3

5 Unit 1 Purge Air Supply Room 318 2

Unit 1 West Piping Pen Rooms 221 and 326 2

3 Unit 1 Letdown Heat Exchanger Room 324 1

Unit i Volume Control TK Room 218 1

Unit 1 ECCS Pump Rooms 118 and 122 7

Unit 1 Coolant Waste Rec TK Room 114 and llE 4

Unit 1 ECCS Pump Rooms 119 and 122 7

Unit 1 Elev 27'-0" Swgr Room Vent Duct 1

Unit 1 Elev 45'-0" swgr Room Vent Duct 1

  • Detection instruments located within the containment are not required to be OPERABLE during the performance of Type A Containment Leakage Rate Tests.
    • Detectors which automatically actuate fire suppression systems.

CALVERT CLIFFS - UNIT 1 3/4 3-45 Amendment No. 26. ff,96

)

TABLE 3.3-11 (Continued)

FIRE DETECTI0'N' INSTRUMENTS UNIT 1 INSTRUMENT LOCATION MINIMUM INSTRUMENTS OPERABLE HEAT FLAME SM0KE Main Steam Piping Room 315A 6

Hot Machine Shop 223 4

Battery Room 304 and 301 3

Misc. Waste Monitor Tank Room 113 1

Charging Pump Room 115 3

East Piping Room 428 7

North South Corridor 410 4

Spent Fuel Pool 530 5

17 Radiation Chem., Lab Office, Rm. 513, 518 and.519, Corridor 521, 522 and 534 1

16 Cask and Equipment Loading Area Rm. 419,

  • 420, 425, and 426 3

22 Spent Fuel Vent Equip. Room 520 2

Component. Cool Room 228 -

8 Radiation Exchange -Vent Equip. Room 225 4

Boric Hold Tank & Pump Room 217 2

Reactor Cooling Pump Room 216 1

Hot Instrument Shop Room 222 2

Service Water Room 226 3

6 East Piping Room 224 10 Corridor 200, 209, and 210 13 Solid Waste Room 418 and 417 2

3 Spent Resin Metering Tank Room 441 1

Waste Gas Equipment Room 207 1

Auxiliary Feed Tank Room 603 2

Misc. Waste Equipment Room 536 3

Corridor 308 6

N/S Corridor Room 410 4

N/S Corridor Room 308 6

Degasifier Pump Room 220 1

Waste Gas Compressor Room 208 2

CALVERT CLIFFS - UNIT 1 3/4 3-46 Amendment No. 96

TABLE 3.3-11 (Continued)

FIRE DETECTI0'N INSTRUMENTS UNIT 1 INSTRUMENT LOCATION MINIMUM INSTRUMENTS OPERABLE HEAT FLAME SM0KE Main Steam Piping Room 315A 6

Hot Machine Shop 223 4

Battery Room 304 and 301 3

Misc. Waste Monitor Tank Room 113 1

Charging Pump Room 115 3

East Piping Room 428 7

North South Corridor 410 4

Spent Fuel Pool 530 5

17 Radiation Chem., Lab Office, Rm. 513, 518 and 519, Corridor 521, 522 and 534 1

16 Cask and Equipment Loading Area Rm. 419, 420, 425, and 426 3

22 Spent Fuel Vent Equip. Room 520 2

Component Cool Room 228 8

Radiation Exchange Vent Equip. Room 225 4

Boric Hold Tank & Pump Room 217 2

Reactor Cooling Pump Room 216 1

Hot Instrument Shop Room 222 2

Service Water Room 226 3

6 East Piping Room 224 10 Corridor 200, 209, and 210 13 Solid Waste Room 418 and 417 2

3 Spent Resin Metering Tank Room 441 1

Waste Gas Equipment Room 207 1

Auxiliary Feed Tank Room 603 2

Misc. Waste Equipment Room 536 3

Corridor 308 6

N/S Corridor Room 410 4

N/S Corridor Room 308 6

Degasifier Pump Room 220 1

Waste Gas Compressor Room 208 2

CALVERT CLIFFS - UNIT 1 3/4 3-46 Amendment No. 96 j

6.0 ADMINISTRATIVE CONTROLS 6.1 RESPONSIBILITY 6.1.1 The Plant Superintendent shall be responsible for overall facility l

operation and shall delegate in writing the succession to this responsibility during his absence.

6.2 ORGANIZATION 0FFSITE 6.2.1 The offsite organization for facility management and technical support shall be as shown on Figure 6.2-1.

FACILITY STAFF 6.2.2 The Facility organization shall be as shown on Figure 6.2-2 and:

a.

Each on duty shift shall be composed of at least the minimum shift crew composition shown in Table 6.2-1.

b.

At least one-licensed Operator shall be in the control room when fuel is in the reactor.

c.

At least two licensed Operators shall be present in the control room during reactor start-up, scheduled reactor shutdown and during recovery from reactor trips.

d, An individual qualified in radiation protection procedures shall be on site when. fuel is in the reactor.

e.

All CORE ALTERATIONS after the initial fuel loading shall be directly supervised by either a licensed Senior Reactor Operator or Senior Reactor Operator Limited to Fuel Handling who has no other concurrent responsibilities during this operation.

f. - A site Fire Brigade of at least 5 menbers shall be maintained onsite at all times.

The Fire Brigade shall not include the minimum shift crew necessary for safe shutdown of both units (4 members) or any personnel required for other essential functions during a fire emergency.

CALVERT CLIFFS - UNIT 1 6-1 Amendment No. 26, 43

~

CHAIR MAN OF THE BOARD o

tri

  • l PR E51 DENT Q

1 n

I l

[

l i

VICE PRESIDENT

- VICE PRESIDENT

]

VICE PRE 51 DENT VICE PRESIDENT r-------

055RC SUPPLY ELECTRIC INTER-m GENER AL SERVICE 5*

ENGINEERING &

3 CONNECTION AND CONSTRUCTION e

I OPER ATIONS I

c 1

MANAGER 3

  • Corporate Responsibility ELECTRIC

-4 for Fire Protection TEST-Program l

m I

STAFF I

I I

l l

l 8

MANAGER MANAGER MANAGER MANAGER MANAGER MANAGER NUCLEAR QUALITY PRODUCTION l

.m REAL ESTATE &

PROJECT ELECTRIC l

POWER ASSUR ANCE MAINTENANCE 4

OFFICE SERVICES MANAGEMENT ENGINEERING I

i i

i i

I GENERAL PLANT SUPERINTENDENT SUPERVISOR l

DIRECTOR NUCLEAR SUPERVIslNG SECURITY PROJECTS ENGINEER SUPERINTENDENT STAFF STAFF MAINTENANCE PROJECTS &

CALVERT CLIFFS

& MODIFICATIONS ENGINEERING SERVICES NUCLEAR g

GENERATION l

ENGINEERING g

l--------- POSRC e

ASSISTANT GENER AL GENERAL PRINCIPAL I>3 SUPERVISOR NUCLEAR CALVERT CLIFFS SUPER VISOR ENGINEER SECURITY COMPUTER MAINTENANCE MODIFICATIONS SYSTEMS IL

& MODIFICATIONS ENGINEERING d

NUCLEAR NUCLEAR 3

FIRE PREVENTION

(*

UNIT PRINCIPAL ENGINEER PLANT ENGINEERING w

NUCLEAR

.M FIGURE 6.21 N

MANAGEMENT ORGANIZATION CHAR T

?

CALVERT CLIFFS NUCLEAR POWER PLANT BALTIMORE GA5 & ELECTRIC COMPANY N.

N CT

. ~.

CH AIR MAN OF THE BOARD o.>

r-sn PR ESIDENT I

a[

l I

I

]

VICE PRESIDENT VICE PRESIDENT -

l

  • y VICE PRE 510ENT VICE PRESIDENT r-------

055RC SUPPLY ELECTRIC INTER-GENER AL SERVICE 5*

ENGINEERING &

l

=

m CONNECTION ANO CONSTRUC TION

.e I

OPER ATRONS e

i 1

MANAGER 3

  • Corporate Responsibility 4

-4 for Fire Protection l

ELECTRIC TEST Program a

I i

t l

STAFF I

I l

l I

1 I

MANAGER MANAGER MANAGER MANAGER MANAGER MANAGER NUCLEAR QUALITY PRODUCTION 3

REAL ESTATE &

PROJECT ELECTRIC 8

POWER ASSUR ANCE MAINTENANCE

,8 OFFICE SERVICES MANAGEMENT ENGINEERING 9

l I

1-i I

GENERAL-l PLANT SUPERINTENDENT SUPERVISOR l

DIRECTOR NUCLEAR SUPERVl51NG SECtJRITY PROJECT 5 ENGINEER SUPERINTENDENT STAFF STAFF MAINTENANCE PROJECTS &

g

& MODIFICATIONS ENGINEERING CALVERT CLIFFS

)

SERVICE 5 NUCLEAR g

GENERATION ENGINEERING g

I L_______.- POSRC A5515 TANT GENER AL

]

I:l SUPERVISOR NUCLEAR CALVERT CLIFF 5 GENERAL PRINCIPAL 4

i SECURITY COMPUTER SUPERVISOR ENGINEER MAINTENANCE MODIFICATIONS lt SYSTEMS

& MODIFICATIONS ENGINEE RING N

NUCLEAR NUCLEAR 3

FIRE PREVENTION UNIT 4

.y 1

o j

PRINCIPAL ENGINEER h

PLANT ENGINEERING j

p NUCLEAR FIGUR E 6.2-1 Q

M AN AGEMENT ORGANIZATION CHAR T CALVERT CLIFF 5 NUCLEAR POWER PLANT BALTIMORE GAS & ELECTRIC COMPANY gg t

e 1

4 4.0 3

C4 i

i

.. - =

n>c i

=<

fri Manager M*

Nucles Po.e, o

I F

g m

l 1

a n,,,

cene,.

Rent Opsatens Supasw Superm S. icy Traaag b c-iendeni Reme.

Tectacs l

Commmee S*C'S 2

-4

____.,__y.__.y-i i

l SRO PrmW Gewal Precipal Wral hiam General Generd Operatenal 1

Geneal General Ergneer Superwsor Engmeer Superwse Gewal I*#.

Superwsor Supermsw teensng Wsw Superusor nani Menienence M e,tcaimns Operatens S p twso' S"PP*'

Rade,,ren Planning b b Satcy EW Opeations Ch'*S"Y b Controts Engmeermg And fr9neermg Quality Nuclear em 3,,,

3, ppa,,

g,,,,

Nuclear Modifcations Nuciey Assurance Secu ity

[

]

I I

I I

I

)

f SRO ASS 5188 Ekctncg Fedeten Mannmg b incore fuel fuel Cycle ta Chenstry b Contrats Safey W

Managemem Managemem g

=

Group Supass or e Superusar g,oup Group Statt Group Group Mechancal I

2 SRO l

(nntrui Mechenscd Tranno r

w,om M+n=aaace Group I

Superv6er 0"8 w

e k

A0 t

=

comroi LEGEND:

E Room Operator M. Hoector Opwater License I

SRO. Senior Reactor Opwater License

z

.O R**

  • Onsne.",

, for Fue Protection Nagram

"^

Opemor

\\

~

O i

w Figure 6.2.2 g

Organization Chart (Two Unit Operation)- Calvert Cliffs Nuclear Power Plant Baltimore Gas and Electric Company o

1

=

1

-M i

I l

l.

TABLE 6.2-1 MINIAUM SHIFT CREW COMPOSITION #

l Condition of Unit 1 - Unit 2 in MODES 1, 2, 3 or 4 APPLICABLE MODES LICENSE ATEGORY 1, 2, 3 & 4 5&6 SOL **

2 2*

OL**

3 3

l Non-Licensed 3

3 Shift Technical Advisor l##

l##

Condition of Unit 1 - Unit 2 in MODES 5 or 6 LICENSE APPLICABLE MODES CATEGORY 1, 2, 3 & 4 5&6 S0L**

2 1*

OL**

3 2

l Non-Licensed 3

3 Shift Technical Advisor l##

0 CALVERT CLIFFS - UNIT 1 Amendment No. /rfy,gg s

~

TABLE 6.2-1 MINIMUM SHIFT CREW COMPOSITION #

Condition of Unit 1 - Unit 2 in MODES 1, 2, 3 or 4 APPLICABLE MODES LICENSE CATEGORY l, 2, 3 & 4 5&6 SQL**

2 2*

OL**

3 3

l Non-Licensed 3

3 Shift Technical Advisor l##

l##

Condition of Unit 1 - Unit 2 in MODES 5 or 6 LICENSE APPLICABLE MODES CATEGORY 1, 2, 3 & 4 5&6 SOL **

2 1*

OL**

3 2

l Non-Licensed 3

3 Shift Technical Advisor l##

0 CALVERT CLIFFS - UNIT 1 Amendment No. /yJ,4 g 6-4

ADMINISTRATIVE CONTROLS l

b.

A high radiation area in wbich the intensity of radiation is greater than 1000 mrem /hr shall be subject to the provisions of 6.12.1.a. above, and in addition locked barricades shall be t

provided to prevent unauthorized entry into such areas and the keys shall be maintained by the Supervisor-Radiation Control and the Operations Shift Supervisor on duty under their separate administrative control.

r h

6.13 ENVIRONMENTAL QUALIFICATION 6.13.1 By no later than June 30, 1982 all safety-related electrical equip-ment in the facility shall be qualified in accordance with the provisions of: Division of Operating Reactors " Guidelines for Evaluating Environmental Qualification of Class IE Electrical Equipment in Operating Reactors" (DOR Guidelines); or NUREG-0588 " Interim Staff Position on Environmental Qualification of Safety-Related Electrical Equipment", December 1979.

Copies of these documents are attached to Order for Modification of Licenses DPR-53 and DPR-69 dated October 24,1980.

6.13.2 By no later than December 1, 1980', complete and auditable records must be available and maintained at a central location which describe the environmental qualification method used for all safety-related electrical equipment in 's'ufficient detail to document the degree of compliance with the D0R Guidelines or NUREG-0588. Thereafter, such records should be updated and maintained current as equipment is replaced, further tested, or otherwise further qualified.

6.14 SYSTEM INTEGRITY The licensee shall implement a program to reduce leakage from systems outside containment that would or could contain highly radioactive fluids during a serious transient or accident to as low as practical levels. This program shall include the following:

1.

Provisions establishing preventive maintenance and periodic visual inspection requirements, and 2.

Leak test requirements for each system at a frequency not to exceed refueling cycle intervals.

l CALVERT CLIFFS - UNIT 1 6-21 Ofddf Jp//A/894/AM//531 Amendment No. 96

ADMINISTRATIVE CONTROLS 6.15 IODINE MONITORING The licensee shall implement a program which will ensure the capability to accurately determine the airborne iodine concentration in vital areas under accident conditions. This program shall include the following:

1.

Training of personnel, 2.

Procedures for monitoring, and 3.

Provisions for maintenance of sampling and analysis equipment.

CALVERT CLIFFS - UNIT 1 6-22 Amendment No. 53 1

ADMINISTRATIVE CONTROLS 6.15 IODINE MONITORING The licensee shall implement a program which will ensure the capability to accurately determine the airborne iodine concentration in vital areas under accident conditions. This program shall include the following:

1.

Training of personnel, 2.

Procedures for monitoring, and 3.

Provisions for maintenance of sampling and analysis equipment.

4 CALVERT CLIFFS - UNIT 1 6-22 Amendment No. 53

am,u

[I 8

g UNITED STATES g

NUCLEAR REGULATORY COMMISSION 37

[

WASHINGTON, D. C. 20555

\\...../

BALTIM0RE GAS AND ELECTRIC COMPANY DOCKET NO. 50-313 CALVERT CLIFFS NUCLEAR POWER PLANT UNIT NO. 2 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 77 License No. DPR-69 1.

The Nuclear Regulatory Comission (the Comission) has found that:

A.

The application for amendment by Baltimore Gas & Electric Company (the licensee) dated April 9,1984, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Comission's rules and regulations set forth in 10 CFR Chapter I; 8.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations; D.

The issuance of this amendment will not be inimical to the comon defense and security or to the h'ealth and safety of the public; and f1eissuanceofthisamendmentisinaccordancewith10CFRPart E.

. l of the Comission's regulations and all applicable requirements l

Itade been satisfied.

i

v 2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.2 of Facility Operating License No. LPR-69 is hereby amended to read as follows:

2.

Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No. 77, are hereby incorporated in the license.

The licensee shall operate the facility in accordance with the Technical Specifica-tions.

3.

This license amendment is effective within 30 days of its issuance.

FOR THE NUCLEAR REGULATORY COMMISSION s R. Miller, Chief Operating Reactors Branch #3 Division of Licensing

Attachment:

Changes to the Technical Specifications Date of Issuance: August 8, 1984

ATTACHMENT TO LICENSE AMENDMENT N0. 77

~

FACILTIY OPERATING LICENSE N0. DPR-69 DOCKET NO. 50-318 Replace the following pages of the Appendix "A" Technical Specifications with the enclosed pages. The revised pages are identified by Amendment t

number and contain vertical lines indicating the areas of change. The corresponding overleaf pages are provided to maintain document completeness.

Pages 3/4 3-45 3/4 3-46 6-2 6-3 6-21

--n a

km.-

~

TABLE 3.3-11 FIRE ~ DETECTION INSTRUMENTS

-UNIT 2-INSTRUMENT LOCATION MINIMUM INSTRUMENTS OPERABLE

  • HEAT FLAME SM0KE

' Unit 2 East Elec Pen Room 409 3

Unit 2 West Elec Pen Room 414 3

Unit.2 Switchgear' Elev 27'-0" Room 311**

6 Unit 2 Switchgear Elev 45'-0". Room 407**

8 Unit 2 Elec Equip Room 532 3

3"l**E:"l1::;;"^;;'*

i Unit'2 Cont East RCPS*

16 Unit 2 Cont West RCPS*

16 Unit 2 Main Plant Exh Equip Room 526 8

Unit-2 Personnel Access. Area Room 527 3

i Cable Tunnel-U-2 Elev 83'-0" 4

l.

~ Cable Chase 2A 1

- Cable Chase' 2B 1

Unit 2 C.S.R. & Cable Chase 2C**

2 10 Unit 2 Letdown Heat Exchanger Room 322 1

Unit 2 Volume Control Tank Room 214 1

Unit' 2 Cool Waste Rec TK Room 107 and 109 4

l

^

Unit 2 ECCS Pump Rooms 101 and 120 7

Unit 2 Pump. Room 108 Elev- (-) 10'-0" l

Unit 2 Intake Structure 48 Unit 2 Elev 27'-0" Swgr Room Vent Duct 1

Unit 2-Elev 45'-0" Swgr Room Vent Duct 1

. Unit 2 ECCS Pp Rooms 102 and 120 7

21 Diesel Generator **

2 Unit 2 Refueling Water Tk Pp Room 440 2

Unit 2 East Pp Pen Rooms 206 and 310 3

5

+

- Unit 2 Purge Air Supply Room 312 2

Unit 2 Hest Piping Pen Rooms 211 and 321 2

3 i'

  • Detection instruments located within the containment are not required to be LOPERABLE during the performance of Type A Containment Leakage Rate Tests.
    • Detectors which automatically actuate fire suppression systems.

I CALVERT CLIFFS - UNIT 2 3/4 3-45 Amendment No. JJ, fyy, 77 I

l I'

i-

TABLE 3.3-11_(Continued)

FIRE DETECTION INSTRUMENTS INSTRUMENT LOCATION MINIMUM INSTRUMENT OPERABLE HEAT FLAME SM0KE Main Steam Piping Room 309 6

East Piping Area Room 203 10 Charging Pump Rocm 105 3

Battery Room 307 and 305 3

Misc. Waste Monitor Tank Room 1

East Piping Area Room 408 7

Component Cooling Room 201~

9 Radiation Exchange Equip. Room 204 4

Boric Acid Tank and Pump Room 215 2

Reactor Cooling Pump Room 216A 2

Service Water Room 205 3

6 Auxiliary Feed Pump Room 605 2

Degasifier Pump Room 1

CALVERT CLIFFS - UNIT 2 3/4 3-46 Amendment,No,77 I

1.

TABLE 3.3-11'_(Continued)

FIRE DETECTION INSTRUMENTS INSTRUMENT LOCATION MINIMUM INSTRUMENT OPERABLE HEAT FLAME SM0KE Main Steam Piping Room 309 6

East Piping Area Room 203 10 Charging Pump Room 105 3

Battery Room'307 and 305 3

Misc. Waste Monitor Tank Room 1

East Piping Area Room 408 7

Component Cooling Room 201 9

Radiation Exchange Equip. Room 204 4

Boric Acid Tank and Pump Room 215 2

Reactor Cooling Pump Room 216A 2

Service Water Room 205 3

6 Auxiliary Feed Pump Room 605 2

Degasifier Pump Room 1

4 i

CALVERT CLIFFS - UNIT 2 3/4 3-46 Amendment No..

77

6.0 ADMINISTRATIVE CONTROLS 6.1 RESPONSIBILITY 6.1.1.The Plant Superintendent shall be responsible for overall facility operation and shall delegate in writing the succession to this responsi-bility during his absence, 6.2 ORGANIZATION OFFSITE 6.2.1 !The offsite organization for facility management and technical support shall be as shown on Figure 6.2-1.

FACILITY STAFF 6.2.2 The Facility organization.shall be as shown on Figure 6.2-2 and:

a.

Each on duty shift shall be composed of at least the minimum shift crew composition shown in Table 6.2-1.

b.

At least one licensed Operator shall be in the control room when fuel is in the reactor, c.

At least two licensed Operators shall be present in the control room during reactor start-up, scheduled reactor shutdown and during recovery from reactor trips.

~

d.'

An individual qualified in radiation protection procedures shall be on site when fuel is in the reactor.

e.

All CORE ALTERATIONS after the initial fuel loading shall be directly supervised by either a licensed Senior Reactor Operator or Senior Reactor Operator Limited to Fuel Handling who has no other concurrent responsibilities during this operation.

f.

A site Fire Brigade of at least 5 members shall be maintained onsite at all times.

The Fire Brigade shall not include the minimum shift crew necessary for safe shutdown of both units (4 members) or any personnel required for other essential functions during a fire emergency.

CALVERT CLIFFS - UNIT 2 6-1 Amendment No. /I.26 L f

J CHAIRMAN Q

OF,THE BOARD E

h.

L,

]

4 PRESIDENT

.ne ' A

' :n 4

?

O

. 'z r

r- '

I I

I

'I VICE PRESIDENT,

VICE PRESIDENT l--------

OSSRC VICE PRESIDENT

'1 GENER AL SERVICES

  • ENGINEERING &

j VICE PRESIDENT.

g SUPPLY ELECTRIC INTER :

CONSTRUCTION s

e 1

^

CONNECTION AND 2

OPER ATIONS E

\\a

-l z

  • Corporate Responsibility 0

y for Fire Protection l

4 i

l MANAGER Program ELECTRIC

/

f TEST

/'/

s a

'[,'

l l

.SrAFr c

1 I

l

\\ l s

I I

r MANAGER MANAGER MANAGER 8

~ MANAGER I

' MANAGER _

MANAGER I'

REAL ESTATE &

PROJECT ELECTRIC 8

KUCLEAR QUALITY

  • PRODUCTION f

OFFICE SERVICES MANAGEMENT ENGINEERING h-POWER ASSURANCE MAINTENANCE '

4 ra l

g I

l l

l e

DIRECTOR NUCLEAR SUPERVISING l

GENERAL PLANT L

SUPERINTENDENT SUPERVISOR SECURITY PROJECTS ENGINEER SUPERINTENDENT STAFF STAFF MAINTENANCE PROJECTS &

g SERVICES NUCLEAR CALVERT CLIFFS

& MODIFICATIONS ENGINEERING g

GENERATION ENGINEERING i

g

+<

L.....----

l

s POSRC

+

ASSISTANT GENER AL m

SUPERVISOR NUCLEAR CALVERT CLIFFS 5

SECURITY COMPUTER GENERAL PRINCIPAL SYSTEMS

SUPERVISOR ENGINEE9 8

MAINTENANCE MODIFICATidNS FIRE PREVENTION

& MODIFICATIONS ENGINEERING y.

UNIT NUCLEAR NUCLEAR

?

M PRINCIPAL ENGINEER PLANT ENGINEERING w

NUCLEAR'

?

FIGUR E 6.2-1 MANAGEMENT ORGANIZATION CHAR T M*

CALVERT CLIFFS NUCLEAR POWER PLANT BALTIMORE GAS & ELECTRIC COMPANY

.D l

7 CHAIR MAN

)

g OF THE BOARD 3=

<m g

PR E51 DENT I

h l

I i

l VICE PRE $iDENT VICE PRESIDENT

(-------

055RC 71 GENERAL SERVICES

  • ENGINEERING &

VICE PRE 51 DENT VICE PRE 510ENT-SUPPLY ELECTRIC INTER-CONSTR UCTION e

CONNECTION AND 8

OPER AT10N5 E

  • Corporate Responsibility y

for Fire Protection MANAGER Program ELECTRIC TEST 8

l 1

e STAFF I

l I

I I

MANAGER MANAGER MANAGER 8

MANAGER MANAGER MANAGER REAL ESTATE &

PROJECT ELECTRIC NUCLEAR QUALITY PRODUCTION f

OFFICE 5ERVICES MANAGEMENT ENGINEERING l

POWER ASSURANCE MAINTENANCE [

fJ l

l I

l DIR ECTOR NUCLEAR SUPERVISING GENERAL PLANT SUPERINTENDENT SUPER'/150R l

SECURITY PROJECT 5 ENGINEER SUPERINTENDENT STAFF STAFF MAINTENANCE PROJECT 5 &

l l

SERVICES NUCLEAR CALVERT CLIFFS

& MODIFICATIONS ENGINEERING l

g GENERATION ENGINEERING g

l L._.......-

s POSRC A5515 TANT GENER AL SUPERVISOR NUCLEAR CALVER T CLIFFS k

SECURITY COMPUTER GENERAL PRINCIPAL SUPERVISOR ENGINEER SYSTEMS o

MAINTENANCE MODIFICATIONS FIRE PREVENTION

& MODIFICATIONS ENGINEERING y

UNIT NUCLEAR NUCLEAR o

M po PRINCIPAL ENGINEER PLANT ENGINEERING w

NUCLEAR 7

FIGUR E 6.2-1 MANAGEMENT ORGANIZATION CHAR T CALVERT CLIFF 5 NUCLEAR POWER PLANT BALTIMORE GAS & ELECTRIC COMPANY

.Y

n33 r-

<m D-i Manager g

Nuclear r--

Power w

i 11 r

E I

I I

I Plant General Rant Operatens Supervo w j

E Supere Satery -

Irwung b

- - - - - =

m tendent Reww Technral H

l Commmee Sm:cas to y

.,, y -

y 9

i i

Gened Prmceal Geneal ProcW Genus Asseiant SRO General General Operational Geneal General 99,

Engmeer Supennsor Engmeer Supervoor General fechrucal.

S,,,n,,,

t, Supervsw Supervow Rant Mantenance Meficatens Oscatens Supeves D'

g i,ci,,,,,

Raeaten Plannmg b b Satefy Oceatens Ch'**V Engmeermo And Engmeermg DJty Nuclear 4

Group b Controls

$g, g,,,,

g, m

Nuclear Mefiratens Nuclear Assuraace Secunty L.

I I

I I

I I

I

}

Elecirth Ra&aten Plannmg b incore Fuei Fuel Cycle i

Stutt b Controls gN y,g, Safety Support Management Managemeni

=

==

j Supe'viss Group Group S'8tf Group Group MM 1

i W

I i

SRO Controi Mechancal j

Room M*ntenance 7,q q

g Supe < visor G'oup g,,,

j a

~

i Q

RO i

m tnnnoi LEGEN0:

j 3

Room j

Operat '

RO kw Wer M 4

z O

H SR0 - Senior Reactw Operator license -

I y

o,"',,",',

  • Onste T,

, for Fwe Protection Propam

-a N

4 Figure 6.2.2 Organization Chart (Two Unit Operation) - Calvert Cliffs Nuclear Power Plant

]

Baltimore Gas and Electric Company i

i 1

n 3

TABLE 6.2-1 MINIMUM SHIFT CREW COMPOSITION #

i Condition of Unit 2 - Unit 1 in MODES 1, 2, 3 or 4 LICENSE APPLICABLE H0 DES CATEGORY 1, 2, 3 & 4 5 &~6 SOL **

2 2*

OL**

3 3

4 Non-Licensed 3

3 Shift Technical Advisor l##

l##

Condition of Unit 2 - Unit 1 in MODES 5 or 6 LICE?iSE APPLICABLE MODES l

CATEGORY 1, 2, 3 & 4 5&6 SQL**

2 1*

L OL**

3 2

l Non-Licensed 3

3 Shift Technical Advisor 1##

0 i

l CALVERT CLIFFS - UNIT 2 6-4 Amendment No. 36, aij

C TABLE 6.2-1 MINIMUM SHIFT CREW COMPOSITION #

l Condition of Unit 2 - Unit 1 in MODES 1, 2, 3 or 4 LICENSE APPLICABLE MODES

~~

CATECORY 1, 2, 3 & 4 5&6 SQL**

2 2*

OL**

3 3

Non-Licensed 3

3 Shift Technical Advisor 1##

l##

Condition of Unit 2 - Unit 1 in MODES 5 or 6 LICENSE APPLICABLE MODES CATEGORY 1, 2, 3 & 4 5&6 50L**

2 1*

OL**

3 2

l Non-Licensed 3

3 Shift Technical Advisor 1##

0 CALVERT. CLIFFS - UNIT 2 6-4 Amendment No. 36, 3 9

ADMINISTRATIVE CONTROLS b.

A high radiation area in which the intensity of radiation is greater than 1000 mrem /hr shall be subject to the provisions of 6.12.1.a. above, and in addition locked barricades shall be provided to prevent unauthorized entry into such areas and the keys sharl be maintained by the Supervisor-Radiation Control and the Operations Shift Supervisor on duty under their separate administrative control.

6.13 ENVIRONMENTAL QUALIFICATION 6.13.1 By no later than June 30, 1982 all safety-related electrical equip-ment in the facility shall be qualified in accordance with the provisions of:

Division of Operating Reactors " Guidelines for Evaluating Environmental Qualification of Class IE Electrical Equipment in Operating Reactors" (D0R Guidelines); or NUREG-0588 " Interim Staff Position on Environmental Qualification of Safety-Related Electrical E,quipment", December 1979.

Copies of these documents are attached to,0rder for Modification of Licenses DPR-53 and DPR-69 dated October 24, 1980.

6.13.2 By no later than December 1,1980, complete and auditable records must be available and maintained at a central location which describe the environmental qualification method used for all safety-related electrical equipment in sufficient detail to document the degree of compliance with the D0R Guidelines or NUREG-0588. Thereafter, such records should be updated and maintained current as equipment is replaced, further tested, or otherwise f'urther qualified.

6.14 SYSTEM INTEGRITY The licensee shall implement a program to reduce leakage from systems outside containment that would or could contain highly radioactive fluids during a serious transient or accident to as low 'as practical levels.

This program shall include the following:

1.

Provisions establishing preventive maintenance and periodic visual inspection requirements, and 2.

Leak test requirements for each ' system at a frequency not l

to exceed refueling cycle intervals.

l l

CALVERT CLIFFS - UNIT 2 6-21 9/#f/J9////Spl Amendment E3, 77 1

- ~.

ADMINISTRATIVE CONTROLS 6.15 IODINE MONITORING The licensee shall implement a program which will ensure the capability to accurately determine the airborne iodine concentration in vital areas under accident conditions. This program shall include the following:

1.

Training of personnel, 2.

Procedures for monitoring, and 3.

Provisions for maintenance of sampling and analysis equipment.

l b

CALVERT CLIFFS-UNIT 2 6-22 Amendment No. 36

ADMINISTRATIVE CONTROLS 6.15 IODINE MONITORING The licensee shall implement a program which will ensure the capability to accurately determine the airborne iodine concentration in vital areas under accident conditions. This program shall include the following:

1.

Training of personnel, 2.

Procedures for monitoring, and 3.

Provisions for maintenance of sampling and analysis equipment.

l l

l l

l CALVERT CLIFFS-UNIT 2 6-22 Amendment No. 36