Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20094A964 + (ML20094A964)
- 05000354/LER-1995-022-01, :on 950720,failed to Enter TS 4.0.3 When Conditions Dictated That All EDGs Should Have Been Declared Inoperable Due to Inadequate Analysis by Operator Experience Feedback Program.Counseled Involved Personnel + (ML20094A968)
- ML20094A970 + (ML20094A970)
- ML20094A979 + (ML20094A979)
- TXX-4243, Submits Sixth Biweekly Update on Status,Through 840721,of Important schedule-related Issues for Fuel Load in Late Sept 1984.Control Room HVAC Testing Incomplete.Schedule Slippage of 3 Wks Cannot Be Recovered + (ML20094A985)
- RBG-41968, Application for Amend to License NPF-47,consisting of Change Request 95-10,deleting TS 5.5.12, Biofouling Prevention & Detection, & Various Editorial Corrections + (ML20094A986)
- 05000416/LER-1984-031-01, Forwards LER 84-031-01 & Rept on Investigation Performed to Determine Unit 1 Dependence on Unit 2 Sys,Structures & Components + (ML20094A987)
- ML20094A989 + (ML20094A989)
- 05000368/LER-1984-014, :on 840618,reactor Turbine Trip Occurred at Approx 8% Full Power Due to High Level in Steam Generator A.Caused by Main Feedwater Bypass Regulating Valve E/P Converter Malfunction + (ML20094A992)
- ML20094A995 + (ML20094A995)
- ML20094A998 + (ML20094A998)
- ML20094A999 + (ML20094A999)
- ML20094B000 + (ML20094B000)
- ML20094B002 + (ML20094B002)
- ML20094B006 + (ML20094B006)
- 05000416/LER-1984-031, :on 840601,plant Shutdown Commenced Following Notification to NRC of Deficiency Re Low Flow Rate in Standby Svc Water Sys Due to Higher than Anticipated Frictional Pressure Drops Through Component Loop + (ML20094B008)
- ML20094B009 + (ML20094B009)
- ML20094B013 + (ML20094B013)
- RBG-45096, Forwards Response to NRC Ltr Re Violations Noted in Insp Rept 50-458/95-23.Corrective Actions:Notified Operations Personnel in Mcr,Halted Painting Activities & Immediately Removed Coverings + (ML20094B014)
- ML20094B017 + (ML20094B017)
- ML20094B020 + (ML20094B020)
- ML20094B024 + (ML20094B024)
- ML20094B026 + (ML20094B026)
- HL-5048, Provides Results of Internal Core Spray Piping Insps. GENE-523-A110-1095, Structural Margin Evaluation for Hatch 2 Internal Core Spray Lines, Encl + (ML20094B028)
- ML20094B029 + (ML20094B029)
- ML20094B031 + (ML20094B031)
- 05000237/LER-1984-007-06, :on 840628,during Hot Standby,Fuse 2330-702 Removed,Causing Loss of Automatic Control for Lpci/Component Cooling Water Sys HX Delta P.Caused by Wiring Sys Using Same Fuse Circuits + (ML20094B035)
- ML20094B041 + (ML20094B041)
- 05000373/LER-1984-044, :on 840702,HPCS Quarterly Inservice Test Check Valve 1E22-F006 & Stop Check Valve 1E22-F007 Failed to Prevent Reverse Flow.Caused by Scoring of Disc Seats.Valves Repaired + (ML20094B045)
- TXX-4352, Forwards Rev 1 to 840630 Rept Re Containment Sump Performance & Westinghouse Re Evaluation of Paint & Insulation Debris Effects on Sump Performance.W/O Rept + (ML20094B052)
- HL-5047, Forwards Response to NRC Re Violations Noted in Insp Repts 50-321/95-18 & 50-366/95-18.Corrective Actions: Disciplined Involved Personnel + (ML20094B064)
- ML20094B067 + (ML20094B067)
- ML20094B068 + (ML20094B068)
- ML20094B076 + (ML20094B076)
- ML20094B079 + (ML20094B079)
- ML20094B089 + (ML20094B089)
- ML20094B094 + (ML20094B094)
- ML20094B095 + (ML20094B095)
- 05000374/LER-1984-034-01, :on 840703,survey of Offgas Carbon Bed Vault Identified High Radiation Area.Warning Signs Posted on Door 565 & Security Status Level Upgraded to High Radiation Status + (ML20094B096)
- ML20094B099 + (ML20094B099)
- ML20094B104 + (ML20094B104)
- ML20094B108 + (ML20094B108)
- ML20094B113 + (ML20094B113)
- NRC-84-0105, Responds to 840726 Request for Addl Info Re Seismic Qualification of Thermocouple/Core Cooling Monitor Sys Acceptance Criteria.Termination of Justification for Interim Operation Maintained + (ML20094B116)
- 05000397/LER-1984-061, :on 840614,open Floor Drain Found on 522-ft Elevation of Reactor Bldg.Plant Walkdown Revealed Two Other Drains.Fire Watches Instituted.Drains Will Be Piped Into Floor Drain Sys & Not Sealed as First Planned + (ML20094B120)
- ML20094B129 + (ML20094B129)
- 05000327/LER-1984-042, :on 840627,radiation Monitor 0-RE-90-225 Would Not Provide Automatic Isolation of Direct Releases from Neutralization Tank.Batch Releases Made on 840624 & 25 W/O Compliance W/Limiting Conditions + (ML20094B131)
- ML20094B132 + (ML20094B132)
- 05000305/LER-1984-012, :on 840628,both Trains of Auxiliary Bldg Special Vent Sys Inadvertently Started During Performance of I&C Procedure.Caused by Personnel Error.Both Trains Secured & Realigned for Normal Operation + (ML20094B133)
- ST-HL-AE-1064, Responds to NRC Re Violations Noted in Insp Repts 50-498/83-24 & 50-499/83-24.Corrective Actions:Pittsburgh Testing Lab Redirected to Perform Future Density Testing in Strict Conformance W/Astm D2049-69 + (ML20094B136)
- AECM-84-0393, Forwards Supplemental Info Re Standby Diesel Generator Combustion Air Intake & Exhaust Sys,Per 840802 Discussions, Superseding Info in (AECM-84/0389) + (ML20094B139)