- RBG-41804, Responds to Violations Noted in Insp Rept 50-458/95-10. Corrective Actions:Steps Taken to Increase Sensitivity of Site to Importance of Accuracy in Design & Configuration Control Processes & Instrument Root Valves Closed + (ML20087B878)
- ML20087B881 + (ML20087B881)
- ML20087B892 + (ML20087B892)
- ML20087B898 + (ML20087B898)
- 05000285/LER-1991-030, :on 911210,containment Pressure Reduction Not Terminated When Radiation Monitor RM-060 Removed from Svc. Caused by Breakdown in Written & Verbal Communication & Work Practices.Procedures Revised + (ML20087B908)
- ML20087B912 + (ML20087B912)
- ML20087B913 + (ML20087B913)
- ML20087B915 + (ML20087B915)
- 05000281/LER-1975-015-01, /01T:on 750807,boron Injection Tank Recirculation Valves TV-2884 A,B & C Found Closed.Caused by Air Supply Valve 2-IA-451 Partially Throttled Due to Vibration + (ML20087B918)
- ML20087B921 + (ML20087B921)
- ML20087B929 + (ML20087B929)
- ML20087B932 + (ML20087B932)
- 05000336/LER-1995-028, :on 950704,inadvertent Actuation of ESAS Equipment Occurred.Caused by Inappropriate Wiring Practices. Changed Hardware Design to Reduce Sys Susceptibility to Electronic Noise + (ML20087B937)
- 05000280/LER-1975-015, Updated LER 75-15/01T:on 750803,leaking Fitting on Overhead Gas Compressor B Resulted in Unplanned Release of Radioctive Matl from Site.Caused by Loose Fitting.Leaking Fitting Repaired + (ML20087B941)
- ML20087B948 + (ML20087B948)
- ML20087B954 + (ML20087B954)
- ML20087B958 + (ML20087B958)
- ML20087B965 + (ML20087B965)
- ML20087B999 + (ML20087B999)
- ML20087C002 + (ML20087C002)
- ML20087C005 + (ML20087C005)
- ML20087C014 + (ML20087C014)
- ML20087C018 + (ML20087C018)
- ML20087C020 + (ML20087C020)
- ML20087C022 + (ML20087C022)
- ML20087C027 + (ML20087C027)
- ML20087C032 + (ML20087C032)
- ML20087C041 + (ML20087C041)
- ML20087C062 + (ML20087C062)
- 05000281/LER-1975-019-01, /01T:on 751015,boric Acid Transfer Pump D Motor Failed Resulting in Loss of Recircilation of Boron Injection Tank 2.Caused by Boric Acid Present in Stator Windings. Pump B Placed in Svc + (ML20087C067)
- ML20087C069 + (ML20087C069)
- 05000280/LER-1975-023-01, /01T:on 751013,channels P-1-455,P-1-456 & P-1-457 Found Indicating High by 26.4 psi,42.0 Psi & 29.4 Psi, Respectively.Caused by Overranging of Zero Spring in Prior Calibr.Procedure Revised + (ML20087C070)
- 05000281/LER-1975-018-01, /01T:on 751009,steam Generator Level Transmitter Isolation Valve Body Bonnet Leak Wetted Down RPI Cabling, Causing Grounds & Erratic Indication for 24 Different Rods. Caused by Water Spray + (ML20087C072)
- 05000281/LER-1975-017-01, /01T:on 751003,loop C Leg RTD Failed Low,Causing Protection Signals to Fail Low.Caused by Incorrect Ohmic Characteristic of Connected RTD & Spare.Failed Instruments Replaced + (ML20087C075)
- ML20087C076 + (ML20087C076)
- ML20087C077 + (ML20087C077)
- ML20087C078 + (ML20087C078)
- ML20087C084 + (ML20087C084)
- ML20087C085 + (ML20087C085)
- 05000280/LER-1975-022-01, /01T:on 750927,test of Main Steam Safety Valve Setpoint Indicated Four Valves Not within Plus or Minus 1% of Setpoint.Caused by Setpoint Drift.Valves Adjusted & Retested + (ML20087C089)
- ML20087C090 + (ML20087C090)
- ML20087C092 + (ML20087C092)
- 05000280/LER-1975-019-01, /01T:on 750925,loop B Temperature Change Instrumentation Drifted Low.Caused by Moisture Content of Containment Atmosphere.Spare RTD Placed in Svc & Shutdown Terminated + (ML20087C094)
- ML20087C095 + (ML20087C095)
- 05000280/LER-1975-018-01, /01T:on 750924,loop a Instrumentation Drifted Low. Caused by High Moisture Content in Containment Atmosphere. RTD Will Be Repaired or Replaced + (ML20087C096)
- ML20087C097 + (ML20087C097)
- ML20087C098 + (ML20087C098)
- ML20087C100 + (ML20087C100)
- ML20087C104 + (ML20087C104)
- ML20087C105 + (ML20087C105)
- ML20087C106 + (ML20087C106)