- ML20085M356 + (ML20085M356)
- ML20085M358 + (ML20085M358)
- ML20085M363 + (ML20085M363)
- ML20085M364 + (ML20085M364)
- ML20085M368 + (ML20085M368)
- ML20085M369 + (ML20085M369)
- 05000266/LER-1991-013, :on 911003,nuclear Instrumentation Turbine Runback Occurred.Caused by Positive Voltage Spike on Output of Detectors a & B of Channel N44.Detectors Replaced.W/ + (ML20085M373)
- ML20085M374 + (ML20085M374)
- ML20085M376 + (ML20085M376)
- ML20085M377 + (ML20085M377)
- 05000348/LER-1991-010, :on 911003,operators Manually Tripped Reactor Due to Unexpected Automatic Closure of Main Turbine Governor Valves.Caused by Degraded Dc Voltage Output.Degraded Power Supply Replaced + (ML20085M378)
- 05000324/LER-1991-015-02, :on 911002,unplanned ESF Actuation Occurred While Removing Reactor Low Level Instrumentation from Svc. Caused by Lack of Caution in Surveillance Procedure. Procedure Will Be Revised Re Analog Trip Unit + (ML20085M379)
- ML20085M380 + (ML20085M380)
- ML20085M381 + (ML20085M381)
- 05000374/LER-1991-013-04, :on 911007,breaker for Supply Fan Tripped & Smoke Observed Coming Out of Switchgear 236X Compartment 302B.Caused by Overheating of Relay,Resulting in Mechanical Binding.Relay Replaced + (ML20085M382)
- 05000440/LER-1991-017, :on 911002,high Pressure Core Spray Pump Declared Inoperable Due to Motor Bearing Oil Reservoir Drain Plug Failure.Caused by Design Deficiency.Drain Plugs Will Be Replaced W/Ball Valve Arrangement + (ML20085M384)
- ML20085M385 + (ML20085M385)
- ML20085M386 + (ML20085M386)
- L-95-005, Technical Evaluation Rept on Third 10-yr Interval Inservice Insp Program Plan + (ML20085M387)
- ML20085M388 + (ML20085M388)
- ML20085M390 + (ML20085M390)
- ML20085M395 + (ML20085M395)
- ML20085M396 + (ML20085M396)
- ML20085M400 + (ML20085M400)
- ML20085M404 + (ML20085M404)
- ML20085M406 + (ML20085M406)
- ML20085M407 + (ML20085M407)
- ML20085M408 + (ML20085M408)
- 05000285/LER-1991-021, :on 911004,inadvertent Partial Actuation of Containment Isolation Actuation Sys Occurred.Caused by Improper Switch Contact Stackup.Caution Tag Placed on Switch Until Corrective Actions Completed + (ML20085M410)
- 05000324/LER-1991-016-02, :on 911005,severe Weather Induced Voltage Drop on off-site Distrubution Line,Resulting in Primary Containment Isolations.Caused by Electrical Storm.No Corrective Actions Required + (ML20085M412)
- ML20085M413 + (ML20085M413)
- PY-CEI-NRR-1413, Forwards LERs 91-019-00 & 91-020-00 + (ML20085M415)
- ML20085M416 + (ML20085M416)
- 05000440/LER-1991-019, :on 911006,Tech Spec Surveillance Requirement for Rod Pattern Controller Performed Late.Caused by Personnel Error.Senior Reactor Operator Counseled & Procedures Revised Re Rod Pattern Testing Requirements + (ML20085M418)
- ML20085M420 + (ML20085M420)
- 05000267/LER-1976-002, LER 76/002:on 760201,during Cable Dressing,Battery Charger Input Breaker Tripped.Power Cable Insulation Cut by Conduit Shorting Cable to Ground.Temporary Junction Box & Terminal Installed + (ML20085M423)
- 05000455/LER-1990-006, :on 910930,reactor Containment Fan Cooler 2C Low Speed Breaker Did Not Close.Caused by Miscommunication & Procedural Deficiency.Procedure Revised to Include Emergency Exit Section + (ML20085M425)
- 05000267/LER-1976-005, LER 76/005:on 760207,during Cold Shutdown,Essential 480-volt Bus 2 Tripped,Causing Trip of Three Circulators.Caused by Electrician Carelessness.Electricians Reminded to Be More Careful + (ML20085M426)
- ML20085M427 + (ML20085M427)
- 05000395/LER-1991-008, :on 911019 Preliminary Results of Sixth Inservice Eddy Current Exam on 911004 Indicated 1% of Tubes Inspected Defective.Caused by Stress Corrosion Cracking in Hot Leg Tubesheet.Tubes Plugged or Repaired + (ML20085M428)
- ML20085M435 + (ML20085M435)
- ML20085M436 + (ML20085M436)
- ML20085M441 + (ML20085M441)
- 05000413/LER-1991-021, :on 911002,turbine Trip Resulting in Reactor Trip Occurred When Vendor Sprayed Water Into Electrical Box. Caused by Failure to Properly Seal Conduit Connectors. Connectors Sealed + (ML20085M444)
- 05000267/LER-1976-004, LER 76/004:on760206,during Weekly Surveillance on 1A Standby generator,1B Engine Partially Declutched Under Load.Caused by Clutch Engaging Pressure Not within Acceptable Tolerance + (ML20085M445)
- 05000325/LER-1991-025, :on 911003,HPCI Diaphragm Control Valve for Low Oil Pressure Trip Inoperable.Caused by Oil Leak During Valve Stroking Due to end-of-life Failure of Diaphragm.Diaphragm Replaced & Work Request Initiated + (ML20085M448)
- ML20085M449 + (ML20085M449)
- ML20085M450 + (ML20085M450)
- ML20085M451 + (ML20085M451)
- 05000361/LER-1995-003, :on 950225,discovered Cracking in Rotor Discs. Caused by Stress Corrosion Cracking.Cracks Removed by Excavation + (ML20085M453)
- ML20085M454 + (ML20085M454)