- ML20084B493 + (ML20084B493)
- RBG-17585, Final Deficiency Rept DR-112 Re Class IE Battery Chargers Supplied by Power Conversion Products,Inc.Initially Reported on 830809.Vendor Revised QA Program to Include Better Training + (ML20084B498)
- 05000220/LER-1976-030, :on 760805,review Revealed That Condenser Delta Temp & Discharge Canal Temp Not Recorded Hourly During 760717-22.Caused by Computer Typers Being Down Due to New Instrumentation Installation.Data Through 760731 Invalid + (ML20084B501)
- 05000220/LER-1976-029, :on 760805,milk Sample Not Analyzed for I-131 within 8 Days of Collection.Caused by Mail Backlog Due to Holiday Weekend + (ML20084B505)
- ML20084B508 + (ML20084B508)
- ML20084B513 + (ML20084B513)
- ML20084B519 + (ML20084B519)
- 05000220/LER-1976-025, :on 760627,average Power Range Monitors 11 & 15 Failed to Produce Scram Signal at Required Flow Bias Setpoint.Caused by Setpoint Drift.Instruments Calibr to Required Specs + (ML20084B529)
- ML20084B533 + (ML20084B533)
- 05000220/LER-1976-024, :on 760613,average Power Range Monitors 17 & 18 Failed to Produce Scram Signal at Required Flow Bias Setpoint.Caused by Setpoint Drift.Instrument Recalibr to Required Specs + (ML20084B534)
- 05000220/LER-1976-023, :on 760625,smoke Observed from Relay 4-112 B/40. Caused by Apparently Shorted Coil,Resulting in Blown Fuse. Relay Replaced + (ML20084B546)
- B15247, Requests NRC to Terminate Senior Operator License SOP-10060-3 for DM Emborsky,Effective 950501 + (ML20084B552)
- 05000220/LER-1976-022, :on 760527,review Revealed That Fish Impinged Exceeded ETS Limits During Routine Sampling on 760519-27. Cause Not Related to Station Operation.Species of Fish Involved Migrate Inshore in Spring + (ML20084B557)
- 05000220/LER-1976-020, :on 760423,switch 1B05C,indicating Emergency Cooling High Flow & Isolating Sys,Actuated Higher than Required 19 Psid.Caused by Setpoint Drift + (ML20084B561)
- ML20084B566 + (ML20084B566)
- 05000220/LER-1976-021, :on 760515,shutdown Cooling Sys dc-operated Instrumentation Valve 38-02 Failed to Function.Caused by Open in in Motor Windings.Motor Rewound + (ML20084B570)
- ML20084B573 + (ML20084B573)
- 05000336/LER-1995-016, :on 950428,operator W/Inactive SRO License Assumed Position of Fuel Handling SRO for Movement of Upper Guide Structure Into Rv.Caused by Failure to Recognize Inactive Status.Briefing Conducted + (ML20084B578)
- 05000220/LER-1976-019, :on 760423,turbine Anticipatory Trip Bypass Reactor Scram Switch Actuated Higher than Required Psig During Surveillance Testing.Caused by Setpoint Drift.Switch Recalibr & Returned to Svc + (ML20084B579)
- ML20084B593 + (ML20084B593)
- ML20084B606 + (ML20084B606)
- ML20084B611 + (ML20084B611)
- ML20084B612 + (ML20084B612)
- ML20084B619 + (ML20084B619)
- ML20084B632 + (ML20084B632)
- ML20084B646 + (ML20084B646)
- 05000361/LER-1995-004, :on 941114,valve Release Weight Stuck & Did Not Drop Upon Electronic Actuation & Valve Did Not Open as Required.Replaced Incorrectly Mfg Weight Switch on 950126 & Ensured Correct Positioning + (ML20084B647)
- ML20084B653 + (ML20084B653)
- 3F0595-12, Delay in Performance of Surveillance Resulting in Violation of TSs + (ML20084B668)
- ML20084B670 + (ML20084B670)
- ML20084B676 + (ML20084B676)
- ML20084B677 + (ML20084B677)
- 05000244/LER-1977-002-01, /01T-0:on 770217,Westinghouse Notified That Reactivity Insertion Curve Used for Safety Analyses Not Sufficiently Conservative.Caused by Westinghouse Error + (ML20084B680)
- ML20084B687 + (ML20084B687)
- ML20084B688 + (ML20084B688)
- ML20084B691 + (ML20084B691)
- 05000302/LER-1995-007, :on 950421,inattention to Detail Caused Delay in Performance of Surveillance That Resulted in Violation of Improved Ts.Counselled Individuals Involved & Revised Procedures + (ML20084B692)
- ML20084B694 + (ML20084B694)
- PLA-2050, Informs That Firm Date Not Established for Operation of Safety Parameter Display Sys.Implementation Schedule, Including Operational Date,Will Be Submitted by End of Jan. Extending Date Does Not Reduce Ability to Deal W/Emergency + (ML20084B696)
- 05000414/LER-1995-004, On 950427,component in a Rtb Cubicle Failed to Change State During Surveillance Testing.Cause Due to Required Procedures Not Being Used.Management Counseling Provided to Individual Involved + (ML20084B703)
- ML20084B704 + (ML20084B704)
- 05000244/LER-1977-001-03, /03L-0:on 770103,during Testing,Safety Injection Pump C Failed to Start Manually from Bus Breaker 14.Caused by Weak Spring in Secondary Contact Assembly.Assembly Replaced + (ML20084B709)
- ML20084B711 + (ML20084B711)
- ML20084B712 + (ML20084B712)
- 05000423/LER-1995-004, :on 950322,historical Breaches Affected CR Pressurization & Secondary Containment Vacuum Due to Misinterpretation of Ts.Work Controls Minimized Possibility of Pressure Boundary Breaches + (ML20084B715)
- L-77-228, Forwards Rept on Sys Disturbance 770516 + (ML20084B721)
- BSEP-84-1083, Special Rept 2-SR-84-6:on 840331,fire Barrier Limiting Condition for Operation Initiated to Permit Opening of Door to Allow Ambient Air Circulation Between Computer Room & Control Room.Caused by Inoperable Air Conditioner + (ML20084B728)
- ST-HL-AE-5085, Failure to Meet Requirements of TS Due to Not Performing Required Surveillance on H Recombiner + (ML20084B731)
- ML20084B732 + (ML20084B732)
- 05000244/LER-1976-030-03, /03L-0:on 761217,during Normal Rounds,Liquid Discovered Leaking from Mixed Bed Demineralizer a Inlet Pipe.Caused by Pinhole Leak in Weld Between Pipe & Elbow. Hole Repaired + (ML20084B740)
- ML20084B741 + (ML20084B741)