- 05000272/LER-1983-053-01, /01T:on 831114,radiation Monitoring Channel 1R11a Failed to Isolate Containment Ventilation.Other Channels Indicated Same Problem.Cause Not Stated.Signal Reset,Causing All Channels to Be Blocked + (ML20082K044)
- ML20082K046 + (ML20082K046)
- ML20082K047 + (ML20082K047)
- PLA-1928, Revised Deficiency Rept Re Anchor/Darling Valve Co Globe Valves Used in Throttling Svc within RHR Sys.Initially Reported on 811112.Listed Interim Measures Adequate Until Permanent Mods Implemented + (ML20082K062)
- ML20082K071 + (ML20082K071)
- ML20082K076 + (ML20082K076)
- JAFP-95-0174, Monthly Operating Rept for Mar 1994 for Ja FitzPatrick Nuclear Power Plant + (ML20082K079)
- ML20082K080 + (ML20082K080)
- ML20082K089 + (ML20082K089)
- ML20082K097 + (ML20082K097)
- ML20082K103 + (ML20082K103)
- ML20082K104 + (ML20082K104)
- 2CAN049512, Monthly Operating Rept for Mar 1995 for ANO Unit 2 + (ML20082K115)
- 1CAN049501, Monthly Operating Rept for Mar 1995 for ANO Unit 1 + (ML20082K119)
- ST-HL-AE-3844, Application for Amends to Licenses NPF-76 & NPF-80, Incorporating Proposed Changes to Tech Specs 3.4.9.1 Re Schedule for Withdrawal of Reactor Vessel Matl Surveillance Specimens + (ML20082K120)
- 05000336/LER-1995-013, :on 950314,SPEC 200 Cabinet Electrical Separation Was Not Maintained Due to Installation Error During Original Installation of ATWS Circuit.Enclosed Wiring in Flexible Conduit + (ML20082K128)
- ML20082K130 + (ML20082K130)
- ST-HL-AE-3847, Responds to Confirmatory Items Identified in Station Blackout Safety Evaluation Rept for STP Electric Generating Station,Per + (ML20082K134)
- ML20082K141 + (ML20082K141)
- LIC-91-0146, Forwards Safety Analysis of Operability Re Potential Leak Path Past Valves LCV-383-1 & LCV-383-2,which Concludes That Potential Releases Would Be within 10CFR100 Limits + (ML20082K143)
- ML20082K145 + (ML20082K145)
- ML20082K150 + (ML20082K150)
- ML20082K156 + (ML20082K156)
- ML20082K160 + (ML20082K160)
- ML20082K165 + (ML20082K165)
- ML20082K166 + (ML20082K166)
- ML20082K168 + (ML20082K168)
- ML20082K174 + (ML20082K174)
- ML20082K187 + (ML20082K187)
- ML20082K189 + (ML20082K189)
- 05000333/LER-1995-005-01, :on 950313,discovered That Rv Water Level Trip Setpoint for Containment Cooling Interlock Outside TS Limits.Caused by Personnel Error & Instrument Drift.Piping & Condensing Chamber Modified + (ML20082K192)
- 05000293/LER-1993-003, :on 930301,found Settings of RWCU High Switches Out of Tolerance During Surveillance.Caused Setpoint Drift. Re-calbr DPIS-1243 & DPIS-1244 in Accordance W/Procedure 8.M2-12.1 W/Satisfactory Results 930301 + (ML20082K195)
- 05000425/LER-1995-003, :on 950317,valve Openings Resulted in Loss of Containment Closure During Refueling.Discussed Need for Complete Turnover Communications & How Affected Event W/Personnel from Depts Involved + (ML20082K203)
- ML20082K206 + (ML20082K206)
- ST-HL-AE-5016, Forwards Request for Deviation from Commitment to 10CFR50, App R,Section III.G.2.c for Lack of Suppression in Fire Area 07 in Auxiliary Shutdown Area of Mechanical & Electrical. Auxiliary Bldg Elevation 10 Ft + (ML20082K210)
- ML20082K213 + (ML20082K213)
- ML20082K216 + (ML20082K216)
- ML20082K217 + (ML20082K217)
- ML20082K227 + (ML20082K227)
- ML20082K230 + (ML20082K230)
- ML20082K231 + (ML20082K231)
- ML20082K236 + (ML20082K236)
- ML20082K242 + (ML20082K242)
- ML20082K246 + (ML20082K246)
- ML20082K248 + (ML20082K248)
- ML20082K249 + (ML20082K249)
- 05000298/LER-1995-008, :on 950314,particulate Filter in Erp Normal Range Kaman Was Discovered Missing Due to Defective Procedure.Examined Remaining Monitors & Backup Samplers to Verify Proper Installation of Filters + (ML20082K253)
- ML20082K254 + (ML20082K254)
- ML20082K256 + (ML20082K256)
- ML20082K261 + (ML20082K261)
- ML20082K265 + (ML20082K265)