- 05000298/LER-1995-005, :on 950210,safety Relief Valves Failed to Operate from Control Room.Caused by Rust/Corrosion in Solenoid Valve Assembly Resulting in Binding of Plunger to Bonnet Tube.Failed Solenoid Valves Replaced + (ML20081B803)
- ML20081B805 + (ML20081B805)
- ML20081B807 + (ML20081B807)
- NRC-94-0123, Submits Comments on Repts Discussed During NRC Workshop on Seismic Revisit of IPEEE on 941021 in Rockville,Md + (ML20081B808)
- 0CAN018408, Forwards Amend 10 to Emergency Plan.W/O Encl + (ML20081B810)
- ML20081B813 + (ML20081B813)
- ML20081B817 + (ML20081B817)
- ML20081B820 + (ML20081B820)
- ML20081B821 + (ML20081B821)
- ML20081B823 + (ML20081B823)
- ML20081B826 + (ML20081B826)
- ML20081B827 + (ML20081B827)
- ML20081B829 + (ML20081B829)
- ML20081B831 + (ML20081B831)
- ML20081B832 + (ML20081B832)
- 05000278/LER-1984-004, :on 840125,reactor Coolant Temp Dropped Below 120 F When Feedwater Inadvertently Pumped Into Reactor Vessel.Caused by Operator Error.Level Restored to Normal & Main Steam Line Drains Opened + (ML20081B835)
- 05000373/LER-1984-007, :on 840203,during Surveillance,Rcic Initiated While Reactor at 89% Power.Caused by Improperly Placed Ohmmeter.Water Level & Pressure Quickly Brought Under Control.Technician Involved Disciplined + (ML20081B838)
- ML20081B840 + (ML20081B840)
- ML20081B845 + (ML20081B845)
- ML20081B847 + (ML20081B847)
- ML20081B848 + (ML20081B848)
- ML20081B849 + (ML20081B849)
- ML20081B852 + (ML20081B852)
- ML20081B855 + (ML20081B855)
- ML20081B858 + (ML20081B858)
- 05000366/LER-1984-001, :on 840203,personnel Detected Fracture in 66- Inch Vent Header in Bay 5.Caused by Brittle Facture of Vent Header Matl.Vent Header Will Be Repaired & Addl Changes or Sys Mod Will Be Made to Improve Sys + (ML20081B859)
- ML20081B861 + (ML20081B861)
- 05000263/LER-1984-008, :on 840207,operating Recirculation Pump (P) Shutdown & Associated Pump Set Generator Field Breaker Did Not Trip.Caused by Faulty Field Breaker.Maint Frequency Increased & All Bearings & Rollers Cleaned + (ML20081B862)
- AECM-84-0119, Forwards Requested Info Re Experience Levels of Util Operating Shift Personnel & Expresses Support of Position Taken by Industry Working Group on Operating Shift Experience on 840224 + (ML20081B867)
- ML20081B869 + (ML20081B869)
- JAFP-95-0131, Requests Enforcement Discretion for TS Requirements Re Main Control Room Ventilation + (ML20081B870)
- ML20081B871 + (ML20081B871)
- ML20081B881 + (ML20081B881)
- 05000374/LER-1984-003-03, :on 840202,intended Trip on Sys Auxiliary Transformer Feed Breaker Failed to Occur.Caused by Breaker Plunger Being Too Short.Addl Washers Installed on Plunger Assembly + (ML20081B883)
- ML20081B892 + (ML20081B892)
- ML20081B899 + (ML20081B899)
- ML20081B907 + (ML20081B907)
- 05000361/LER-1984-007, :on 840203 & 04,Train a & B Main Steam Isolation Sys Spuriously Actuated on Low Pressure Signal from E-088.Caused by Voltage Fluctuation Resulting from Electrical Realignments,Testing & Maint + (ML20081B910)