- 05000416/LER-1983-150-99, Limiting Condition for Operation Entered When Five fire-rated Floor Penetrations in Auxiliary Bldg Opened to Route Cable.Caused by Issuing Design Change Package 82-4145 + (ML20080F260)
- 05000498/LER-1994-020, :on 941209,determination Made That Combined Total of 66 Breakers Potentially Out of Tolerance.Caused by Misinterpretation of Acceptance Criteria.Molded Case Circuit Breaker Tests Procedure Revised + (ML20080F263)
- 05000387/LER-1983-114-03, /03L-0:on 830809,at 100% Power,After Preventive Maint,Standby Gas Treatment Sys Train a Started & Fan Tripped on Low Heater Differential Temp.Caused by Maint Directions Supplying Air Flow Signal W/O Flow + (ML20080F264)
- ML20080F267 + (ML20080F267)
- 05000311/LER-1983-043-03, /03L-0:on 830802 & 07,reactor Coolant Flow Channel I,Number 24 Indicated Excessively High.Caused by Static Shift in Transmitter & Failure of Transmitter Oscillator, Respectively.Transmitter Readjusted + (ML20080F268)
- 05000321/LER-1983-075-03, /03L-0:on 830816,reactor Water Cleanup Sys Differential Flow Transmitter 1G31-NO36 Discovered Out of Calibr.Caused by Setpoint Drift.Transmitter Calibr + (ML20080F272)
- 05000281/LER-1983-034-03, /03L-0:on 830813,w/unit at Constant Speed Drive, Periodic Snubber Functional Testing Revealed 23 Snubbers Failed to Meet Required Acceptance Criteria.Caused by Seal Degradation & Scored Piston/Body + (ML20080F274)
- 05000311/LER-1983-042-03, /03L-0:on 830802 & 11,control Rod Position Indicator Channel Indicated Greater than 12 Steps Difference as Compared to Group Demand Indication.Caused by Indicator Reading Low & Signal Conditioner Module Drift + (ML20080F276)
- 05000321/LER-1983-074-03, /03L-0:on 830815 & 18,filter & Demineralizer Conductivity Recorder 1G31-R601 Indicated Different Value than Tech Specs.Caused by Inoperative & Uncalibr Conductivity Meter,Respectively.Meter Calibr + (ML20080F281)
- 05000311/LER-1983-041-03, /03L-0:on 830801 & 09,spurious Actuations of Safeguards Equipment Control Sys Channel a Caused Deenergization of Vital Bus 2A.Possibly Caused by near-short Condition on Output Test Panel Terminals + (ML20080F290)
- ML20080F293 + (ML20080F293)
- ML20080F296 + (ML20080F296)
- ML20080F298 + (ML20080F298)
- AECM-83-0561, Part 21 Rept 2 Re Improperly Assembled Automatic Switch Co Spare Part Kits for Scram Pilot Valve Solenoids.Initially Reported on 830804.Investigation Continuing.Final Rept Will Be Provided by 840224 + (ML20080F299)
- 05000374/LER-1994-010-08, :on 941214,division 2 ECC & RCIC Initiated Due to Ps Isolation Valve Leak.Action Request Was Initiated to Repair Isolation Valve + (ML20080F300)
- 05000271/LER-1983-018-03, /03L-0:on 830809,HPCI Sys Declared Inoperable After Tripping & Resetting Occurred During Vibration Test. Caused by Normal Vibration Loosening Set Screw Holding Piston in Position on Ball & Tappet Holder + (ML20080F301)
- ML20080F308 + (ML20080F308)
- ML20080F310 + (ML20080F310)
- ML20080F320 + (ML20080F320)
- ML20080F324 + (ML20080F324)
- ML20080F325 + (ML20080F325)
- 05000318/LER-1983-041-01, /01T-0:on 830824,malfunction of Main Turbine Control Circuitry Caused Rapid Closure of Intercept & Governor Valves.Possibly Caused by Malfunction of Turbine Runback.Circuits Deactivated + (ML20080F328)
- ML20080F329 + (ML20080F329)
- ML20080F337 + (ML20080F337)
- ML20080F347 + (ML20080F347)
- ML20080F349 + (ML20080F349)
- ML20080F367 + (ML20080F367)
- 05000366/LER-1983-085-03, /03L-0:on 830817,during Control Panel Walkdown in Main Control Room,Torus Water Level Found Below Required Limit.Caused by Personnel Error.Level Restored to Acceptable Limits.Personnel Counseled + (ML20080F369)
- ML20080F372 + (ML20080F372)
- L-83-442, Responds to NRC Re Violations Noted in IE Insp Rept 50-389/83-44.Corrective Actions:Engineering Weld Deficiencies Reviewed,Ncr Initiated for Deficiency,Qc Performed Followup Insp & QC Hold Point Insp + (ML20080F380)
- L-83-461, Responds to NRC Re Violations Noted in IE Insp Rept 50-389/83-44.Corrective Actions:Discrepancies Noted in Connection of Lateral Support to Whip Restraint Reinspected & Documented + (ML20080F392)
- ML20080F396 + (ML20080F396)
- ML20080F404 + (ML20080F404)
- 05000333/LER-1983-030-03, /03L-0:on 830830,AE Advised That Emergency Diesel Generators Could Be Rendered Inoperable If Diesel Exhaust Sys Subjected to Tornado Wind Loads.Exhaust Sys Modified in Lieu of Performing Study + (ML20080F437)
- ML20080F457 + (ML20080F457)
- ML20080F458 + (ML20080F458)
- ML20080F468 + (ML20080F468)
- ML20080F473 + (ML20080F473)
- ML20080F500 + (ML20080F500)
- 05000389/LER-1983-047-03, /03L-0:on 830810,plant Data Processing Computer & Backup Computer Tripped Offline,Rendering Pulse Counting CEA Position Indication & in-core Power Detection Sys Inoperable.Caused by Disc Errors + (ML20080F501)
- AECM-83-0565, Forwards marked-up Proposed Changes to Tech Specs Per 821020 Confirmation of Action Ltr.Changes Intended to Enhance Clarity or Provide Consistency W/Plant Design & Operation. Justification for NSHC Encl + (ML20080F505)
- ML20080F524 + (ML20080F524)
- ML20080F527 + (ML20080F527)
- ML20080F529 + (ML20080F529)
- ML20080F543 + (ML20080F543)
- 0CAN018401, Forwards Remittance for 10CFR170 Fees for Fire Protection Reviews & Approvals,Per NRC + (ML20080F553)
- ML20080F561 + (ML20080F561)
- ML20080F566 + (ML20080F566)
- ML20080F573 + (ML20080F573)
- JAFP-84-0095, Responds to NRC Re Violations Noted in IE Insp Rept 50-333/83-27.Corrective Actions:Individual Involved Counseled on Need for Care in Researching & Reporting Info Re Potential LERs + (ML20080F600)