SEABROOK STATION

" ) (")

M 1", Omen e

1471 Worcesser Road hominehem. Massachveens 01701 (417) - E72 8100 PutAc Service of New Hampshire September 9, 1983 SBN-562 T.F. Q2.2.2 United States Nuclear Regulatory Commission Region I 631 Park Avenue King of Prussia, PA 19406 Attention:

Mr. Richard W. Starostecki, Director Division of Project and Resident Programs

References:

(a) Construction Permit CPPR-135 and CPPR-136, Docket Nos. 50-443 and 50-'44 (b) PSNH Letter, dated J.ine 3,1983, " Interim 10CFR50.55(e)

Report; Suspect NDE Examinations", J. DeVincentis to R. W. Starostecki (c) PSNH Letter, dated July 5, 1983, " Interim 10CFR50.55(e)

Report; Suspect NDE Examinations", J. DeVincentis to R. W. Starostecki (d) USNRC Letter, dated June 27, 1983, " Combined NRC Meeting Nos. 50-443/83-10; 50-444/83-07", R. W. Starostecki to R. J. Harrison (e) PSNH Letter, dated August 4, 1983, " Interim 10CFR50.55(e)

Report; Suspect NDE Examinations", J. DeVincentis to R. W. Starostecki (f) P3NH Letter, dated August 16, 1983, " Interim 10CFR50.55(e)

Report; Suspect NDE Examinations", J. DeVincentis to R. W. Starostecki

Subject:

Interim 10CFR50.55(e) Report; Suspect NDE Examinations

Dear Sir:

In a meeting conducted at Region I Headquarters on June 7,1983, we committed to provide periodic Interim 10CFR50.55(e) Reports on the status of the Pullman-Higgins reexamination / reevaluation program relative to suspect nondestructive examinations performed by a former P-H employee.

Reference (f) indicated that an additional report would be submitted by September 9,1983.

8309190325 830909 PDR ADOCK 05000443

/

S PDR

/gr-1000 Elm St., P.O. Box 330. Manchester. NH 03105 Telephone (603) 6694000 TWX 7102207595 f

Il*

I United States Nuclear Regulatory Commission September 9, 1983 Attention:

Mr. Richard W. Starostecki Page 2 The status as of September 6, 1983, of the reexamination / reevaluation program for the 1,978 suspect items is as follows:

a.

One safety-related weld remains to be reexamined and this will be accomplished as soon as necessary staging is placed.

b.

The present disposition of the 203 (see Reference (f)) welds requiring Engineering evaluation is as follows:

1)

UE&C has recommended that all but two of the safety-related welds should be " accepted-as-is" based on the results of acceptable volumetric examinations performed subsequent to the suspect inspections, 11)

Two safety-related welds which are embedded require further evaluation, and 111) UE&C is in the process of classifying the remaining non-safety-related welds based on service severity levels.

An additional report will be submitted to Region I by October 7, 1983.

Very truly yours, YANKEE ATOMIC ELECTRIC COMPANY John DeVincentis Project Manager l

ALL/pf l

cet Atomic Safety and Licensing Board Service List

)

William S. Jard:n, III, E quire Brentwood Board of Selectmen Harmon & Weiss RED Dalton Road 1725 1 Street, N.W. Suite 506 Brentwood, New Hampshire 03833 Washington, DC 20006 i

Roy P. Lessy, Jr., Esquire Office of the Executive Legal Director Edward F. Meany U.S. Nuclear Regulatory Commission Designated Representative of Washington,.DC 20555 the Town of Rye 155 Washington Road Robert A. Backus, Esquire Rye, NH 03870 116 Lowell Street P.O. Box 516 Calvin A. Canney E

Mancehster, NH 03105 City Manager City Hall Philip Ahrens, Esquire 126 Daniel Street.

Assistant Attorney General Portsmouth, NH 03801 Department of the Attorney General Augusta, ME 04333 Dana Bisbee, Esquire Assistant Attorney General Mr. John B.-Tanzer Office of the Attorney General Designated Representative of 208 State House Annex the Town of Hampton Concord, NH 03842 5 Morningside Drive Hampton, NH 03842 Anne Verge, Chairperson Board of Selectmen Roberta C. Pevear Town Hall Designated Representative of South Hampton, NH 03642 the Town of Hampton Falls Drinkwater Road Patrick J. McKeon Hampton. Falls, NH 03844 Selectmen's Office 10 Central Road Mrs. Sandra Gavutis Rye, NH 03870 Designated Representative of the Town of~Kensington David R. Lewis, Esquire RFD 1 Atomic Safety and Licensing Board East Kingston, NH 03827 U.S. Nuclear Regulatory Commission Washington, D.C. 20555 Jo Ann Shotwell, Esquire J.

Assistant Attorney General Mr. Angie Machiros Environmental Protection Bureat Chairman of the Board of Selectmen Department of the Attorney General Town of Newbury One Ashburton Place,19th Floor Newbury, MA 01950 Boston, MA 02108 Maynard B. Pearson Senator Gordon J. Humphrey 40 Monroe Street U.S. Senate Amesbury, MA 01913 Washington, DC 20510 (Attn: Tom Burack)

Senator Gordon J. Humphrey 1 Pillsbury Street Diana P. Randall Concord, NH 03301 70 Collins Street (Attn: ' Herb Boynton)

[

SEabrook, NH 03874 l.

Richard E. Sullivan, Mayor Donald E. Chick City Hall Town Manager Newburyport, MA 01950 Town of Exeter 10 Front Street Exeter, NH 03833 l

l l

I

_ _ _ _ _.. - _ _ _ _