Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20080D727 + (ML20080D727)
- ML20080D734 + (ML20080D734)
- 05000361/LER-1983-088-03, /03L-0:on 830719,Channel D Plant Protection Sys Power Supply Voltage Found Out of Range.Caused by Normal Operation.New Power Supply Installed + (ML20080D737)
- LD-83-098, Responds to IE Bulletin 83-05, ASME Nuclear Code Pumps/Spare Parts Mfg by Hayward Tyler Pump Co. Hayward Tyler Pumps & Spare Parts Will Not Be Used in safety-related Sys + (ML20080D739)
- 05000259/LER-1983-049-01, /01T-0:on 830811,while Performing Ultrasonic Insp of Core Spray,Rhr Head Spray & Reactor Water Cleanup Piping, crack-like Indications Detected & Confirmed on Welds.Caused by Intergranular Stress Corrosion Cracking + (ML20080D742)
- ML20080D761 + (ML20080D761)
- ML20080D771 + (ML20080D771)
- ML20080D790 + (ML20080D790)
- ML20080D792 + (ML20080D792)
- ML20080D793 + (ML20080D793)
- ML20080D794 + (ML20080D794)
- ML20080D803 + (ML20080D803)
- ML20080D807 + (ML20080D807)
- ML20080D813 + (ML20080D813)
- ML20080D818 + (ML20080D818)
- ML20080D823 + (ML20080D823)
- ML20080D825 + (ML20080D825)
- ML20080D834 + (ML20080D834)
- ML20080D835 + (ML20080D835)
- AECM-83-0480, RO 83-071/0:on 830717,fire Rated Doors Blocked Open to Support Planned Maint Activities.Doors Restored on Listed Dates.Fire Watches Established Until Doors Restored + (ML20080D847)
- ML20080D861 + (ML20080D861)
- BECO-84-016, Forwards Rev 14 to Modified Amended Security Plan.Rev Withheld (Ref 10CFR73.21) + (ML20080D866)
- RBG-15-695, Interim Deficiency Rept DR-92 Re Failure of Supplier & Subsuppliers to Have ASME III Documentation for Category I Stainless Steel Thermowells.Initially Reported on 830114. Util Awaiting Ae Info.Next Rept by 830920 + (ML20080D868)
- ML20080D870 + (ML20080D870)
- ML20080D873 + (ML20080D873)
- ML20080D876 + (ML20080D876)
- ML20080D886 + (ML20080D886)
- ML20080D892 + (ML20080D892)
- ML20080D902 + (ML20080D902)
- ML20080D905 + (ML20080D905)
- 0CAN078314, NPDES Noncompliance Notification:On 830604,flow Limitation for Outfall 004,low Vol Wastewater Exceeded Due to Discharge of 332,748 Gallons or 0.33 Mgd.Caused by Breakdown in Tracking Mechanism.Procedures Revised + (ML20080D906)
- ML20080D913 + (ML20080D913)
- ML20080D915 + (ML20080D915)
- ML20080D920 + (ML20080D920)
- NRC-84-0017, Forwards Proprietary Response to NRC Comments on Steam Generator Tube Plugging Requirements.Requests That Tech Spec Tube Plugging Limit for Snupps Model F Steam Generators Be Established.Response Withheld (Ref 10CFR2.790) + (ML20080D924)
- ML20080D928 + (ML20080D928)
- ML20080D929 + (ML20080D929)
- ML20080D931 + (ML20080D931)
- ML20080D934 + (ML20080D934)
- ML20080D939 + (ML20080D939)
- RBG-15-671, Responds to IE Bulletin 83-05 Re ASME Nuclear Code Pumps & Spare Parts Mfg by Hayward Tyler Pump Co.Total of Four safety-related Hayward Tyler ASME Code Pumps Used in Standby Svc Water Sys + (ML20080D940)
- ML20080D943 + (ML20080D943)
- ML20080D946 + (ML20080D946)
- ML20080D950 + (ML20080D950)
- PY-CEI-NRR-0067, Forwards Clarifications Requested During 830818 Meeting Re Amend 12 to FSAR Section 17.2 Concerning Operational QA Program & Table 3.2-1, Equipment Classification. Encl Clarifications Will Be Incorporated Into Next FSAR Amend + (ML20080D951)
- 05000249/LER-1983-028-03, /03L-0:on 830723,differential Pressure Switch Ps 1349A Actuated Above Tech Spec Limit of 32.0 Inches of Water.Caused by Inadvertent Adjustment of High Differential Pressure Isolation Potentiometer + (ML20080D953)
- ML20080D955 + (ML20080D955)
- ML20080D957 + (ML20080D957)
- TXX-4034, Forwards Supplemental Response to Items 1.b,4 & 6 of SER Suppl 2,Section II.B.3 Open Items Re post-accident Sampling Sys + (ML20080D961)
- ML20080D962 + (ML20080D962)
- ML20080D963 + (ML20080D963)