- ML20079R163 + (ML20079R163)
- ML20079R164 + (ML20079R164)
- ML20079R165 + (ML20079R165)
- ML20079R169 + (ML20079R169)
- ML20079R175 + (ML20079R175)
- 05000272/LER-1983-067-03, /03L-0:on 831220,minor Leak Developed on Diesel Cooling Water Expansion Tank.Caused by Bushing Wear Allowing Radial Shaft Movement.Leak Repaired,Pump Tested & Declared Operable + (ML20079R176)
- ML20079R177 + (ML20079R177)
- ML20079R182 + (ML20079R182)
- ML20079R195 + (ML20079R195)
- ML20079R196 + (ML20079R196)
- ML20079R203 + (ML20079R203)
- ML20079R206 + (ML20079R206)
- ML20079R208 + (ML20079R208)
- A840071, Final Deficiency Rept Re Agastat Relay Bases Not Tightened to Metal Channels in Power Generation Control Complex Per GE Instructions.Initially Reported on 830811.All Bases Will Be Inspected & Replaced as Needed by 840601 + (ML20079R209)
- ML20079R212 + (ML20079R212)
- ML20079R214 + (ML20079R214)
- ML20079R217 + (ML20079R217)
- ML20079R222 + (ML20079R222)
- ML20079R225 + (ML20079R225)
- ML20079R227 + (ML20079R227)
- ML20079R232 + (ML20079R232)
- 05000317/LER-1983-069-03, /03L-0:on 831221,during Test of Reactor Trip Circuit Breaker (Tcb) Undervoltage (UV) Devices,Response Time of Tcb 2 & 6 UV Trip Devices Found Too Slow.Caused by Setpoint Drift.Uv Devices Replaced + (ML20079R233)
- ML20079R237 + (ML20079R237)
- ML20079R239 + (ML20079R239)
- ML20079R242 + (ML20079R242)
- ML20079R245 + (ML20079R245)
- ML20079R249 + (ML20079R249)
- ML20079R251 + (ML20079R251)
- ML20079R254 + (ML20079R254)
- ML20079R259 + (ML20079R259)
- ML20079R263 + (ML20079R263)
- ML20079R266 + (ML20079R266)
- 05000272/LER-1983-063-03, /03L-0:on 831214,axial Flux Difference Recorder & Monitor Alarm Not Monitored & Logged When Removed from Svc to Perform Routine Change of Target Flux Difference Value.Caused by Personnel Error + (ML20079R272)
- B11006, Forwards Amend 5 to Environ Rept - OL Stage,In Response to NRC 831007 Request for Addl Info + (ML20079R291)
- ML20079R298 + (ML20079R298)
- ML20079R305 + (ML20079R305)
- ML20079R307 + (ML20079R307)
- ML20079R308 + (ML20079R308)
- ML20079R310 + (ML20079R310)
- ML20079R312 + (ML20079R312)
- 05000255/LER-1983-037-01, /01T-0:on 830601,rack Mounted Circuit Board Replaced W/One from Stock Resulting in Total Loss of Valve Control During Restoration of Automatic Control of CV-0737A. Caused by Faulty Rack Mounted Circuit Board + (ML20079R325)
- ML20079R384 + (ML20079R384)
- ML20079R417 + (ML20079R417)
- 05000260/LER-1984-001, :on 840108,during RCIC Flow Testing,Rcic Failed to Reach Rated Flow in Required 30 S.Caused by Probable Setpoint Drift.Electronic Governor Control Sys Recalibr + (ML20079R421)
- ML20079R425 + (ML20079R425)
- ML20079R430 + (ML20079R430)
- ML20079R438 + (ML20079R438)
- ML20079R439 + (ML20079R439)
- 05000333/LER-1983-067-03, /03L-0:on 831228,while Conducting Surveillance Testing on RCIC Turbine Steam Line High Flow Switch 13-DPIS-84,setpoint Found Less Conservative than Required. Caused by Instrument Drift.Setpoint Corrected + (ML20079R447)
- ML20079R453 + (ML20079R453)
- ML20079R455 + (ML20079R455)