- ML20079N372 + (ML20079N372)
- 05000316/LER-1983-052-03, During Normal Operation, Reactor Trip Occurred as Result of Failure in 120-volt Ac Vital Bus Inverter.Caused by Capacitor C-2 Failure Due to High Operating Temps.Capacitor & Fuse Replaced + (ML20079N373)
- ML20079N374 + (ML20079N374)
- ML20079N375 + (ML20079N375)
- ML20079N376 + (ML20079N376)
- 05000316/LER-1983-081, Updated LER 83-081/03X-1:on 830822 & 25,during Normal Operation,Reactor Trips Occurred as Result of Failures of 120-volt Ac Vital Bus Inverter.Caused by Operating Temps Above Rated Design Temps.Forced Air Cooling Installed + (ML20079N378)
- ML20079N379 + (ML20079N379)
- ML20079N380 + (ML20079N380)
- ML20079N382 + (ML20079N382)
- ML20079N385 + (ML20079N385)
- ML20079N388 + (ML20079N388)
- 05000331/LER-1982-080, Forwards Updated LER 82-080/03X-1 + (ML20079N389)
- ML20079N391 + (ML20079N391)
- 05000331/LER-1982-080-03, River Water Supply Sys Traveling Screen Wash Pump 1P-112B Found W/Discharge Head Below Tech Spec Requirement for Traveling Screen 1F-36B. Caused by Unaligned Pump & Motor.Pump/Motor Realigned + (ML20079N394)
- ML20079N395 + (ML20079N395)
- ML20079N396 + (ML20079N396)
- ML20079N397 + (ML20079N397)
- ML20079N401 + (ML20079N401)
- ML20079N404 + (ML20079N404)
- ML20079N408 + (ML20079N408)
- ML20079N410 + (ML20079N410)
- ML20079N411 + (ML20079N411)
- ML20079N412 + (ML20079N412)
- ML20079N413 + (ML20079N413)
- ML20079N416 + (ML20079N416)
- ML20079N419 + (ML20079N419)
- ML20079N421 + (ML20079N421)
- ML20079N423 + (ML20079N423)
- ML20079N427 + (ML20079N427)
- ML20079N429 + (ML20079N429)
- 05000416/LER-1983-192-03, /03L-0:on 831223,first Shift Failed to Adequately Perform 12 H Channel Check of Tech Spec 4.3.7.1-1.7.Caused by Personnel Error.Daily Operating Log Being Revised + (ML20079N434)
- ML20079N442 + (ML20079N442)
- ML20079N446 + (ML20079N446)
- ML20079N447 + (ML20079N447)
- ML20079N451 + (ML20079N451)
- ML20079N452 + (ML20079N452)
- ML20079N456 + (ML20079N456)
- ML20079N461 + (ML20079N461)
- ML20079N467 + (ML20079N467)
- ML20079N471 + (ML20079N471)
- 05000259/LER-1984-001, :on 840103,RHR Pump 1D Started W/O Receiving Automatic Signal or Manual Start Signal from Control Room. Caused by Laborers Performing Decontamination Work.Laborers Cautioned + (ML20079N477)
- ML20079N492 + (ML20079N492)
- 05000395/LER-1983-143-03, /03L-0:on 831224,while in Mode 1,indication for Condensate Storage Tank Level Transmitter LT-3621 Failed High Because of Frozen Instrument Lines.Caused by Abnormally Cold Temp.Heat Trace Setpoints Increased + (ML20079N495)
- ML20079N497 + (ML20079N497)
- 05000315/LER-1983-128-03, /03L-0:on 831226,during Performance of Diesel Generator AB Operability Test,Diesel Generator Tripped on Apparent Overspeed Condition.Caused by Loose Ground Wire Associated W/Electronic Tachometer Circuit + (ML20079N502)
- ML20079N506 + (ML20079N506)
- 05000315/LER-1983-129-03, /03L-0:on 831228,during Normal Operation,Fire Door 471 Would Not Fully Close & Latch.Caused by Latch Plate Being Misaligned W/Latch Bolt of Active Leaf.Latch Plate Aligned & Door Closers Adjusted + (ML20079N508)
- ML20079N512 + (ML20079N512)
- ML20079N513 + (ML20079N513)
- 05000315/LER-1983-130-03, /03L-0:on 831230,during Normal Operations,Air Leak Discovered on Steam Generator Blowdown Sample Containment Isolation Valve 4 (DCR-304).Caused by Degraded O-ring Inside Valve operator.O-ring Replaced + (ML20079N516)
- ML20079N521 + (ML20079N521)