- 05000416/LER-1982-138, Interim LER 82-138/99X-0:on 821112,during Shutdown,Several Duct Covers Could Not Be Installed Due to Cables Extending Through Ducts.Caused by Faulty Design Document.Engineering Evaluation Underway + (ML20079J271)
- ML20079J273 + (ML20079J273)
- ML20079J278 + (ML20079J278)
- 05000266/LER-1982-025, Forwards LER 82-025/03L-0 + (ML20079J280)
- 05000366/LER-1982-122, Forwards LER 82-122/03L-0 + (ML20079J286)
- 05000366/LER-1982-122-03, /03L-0:on 821123,during Mode 1 at 2,417 Mwt,Fire Detector Surveillance safety-related Areas Procedure Not Completed by Latest Possible Date (821123).Caused by Personnel Oversight.Personnel Counselled + (ML20079J292)
- ML20079J295 + (ML20079J295)
- 05000266/LER-1982-025-03, /03L-0:on 821117,while Reviewing Test Data,Two 480-volt Safeguards Undervoltage Relays Found Not Meeting 0 Volt Time Delay Spec.Relays Adjusted to within Spec & Returned to Svc + (ML20079J296)
- ML20079J298 + (ML20079J298)
- 05000250/LER-1982-017, Forwards LER 82-017/03L-0 + (ML20079J303)
- 05000370/LER-1983-084-03, /03L-0:on 831206,during Performance of Chemical & Vol Control Sys Valve Stroke Timing Test,Valve 2NV-842A,C Failed to Close within Required Closure Time.Caused by Failed Electrical Contact + (ML20079J309)
- ML20079J310 + (ML20079J310)
- ML20079J311 + (ML20079J311)
- ML20079J312 + (ML20079J312)
- 05000250/LER-1982-017-03, /03L-0:on 821119,during Control Room Mods,Two Fire Barrier Penetrations Disabled Intentionally for Longer than 7 Days.Action Taken to Implement Approved Design Mods to Control Room + (ML20079J315)
- IR 05000327/2020011 + (ML20079J317)
- ML20079J321 + (ML20079J321)
- 05000250/LER-1982-016, Forwards LER 82-016/03L-0 + (ML20079J323)
- ML20079J325 + (ML20079J325)
- ML20079J326 + (ML20079J326)
- ML20079J335 + (ML20079J335)
- 05000250/LER-1982-016-03, /03L-0:on 821119,during Insp of Fire Protection Sys,Fire Barrier Penetration (Laundry Room West Doors) Found Nonfunctional.New Doors/Parts Ordered & Will Be Installed Upon Receipt + (ML20079J336)
- ML20079J339 + (ML20079J339)
- 05000416/LER-1982-139, Forwards LER 82-139/03L-0 + (ML20079J341)
- ML20079J345 + (ML20079J345)
- ML20079J346 + (ML20079J346)
- PM-82-132, RO 50-321/1982-003:on 821127,air Compressor in Cooling Tower 1B Fire Protection Spray Sys Failed,Dropping Air Pilot Detection Sys Pressure.Dropped Pressure Caused Actuation of Two Deluge Valves Which Started Fire Pumps + (ML20079J348)
- ML20079J349 + (ML20079J349)
- 05000416/LER-1982-139-03, /03L-0:on 821118,smoke Detector in Control Cabinet Room Alarmed & Would Not Reset.No Smoke or Fumes Present in Area.Caused by Defective Detector.Fire Watch Established & Detector Replaced + (ML20079J350)
- ML20079J354 + (ML20079J354)
- ML20079J357 + (ML20079J357)
- ML20079J359 + (ML20079J359)
- ML20079J363 + (ML20079J363)
- 05000373/LER-1982-158, Forwards LER 82-158/03L-0 + (ML20079J368)
- ML20079J370 + (ML20079J370)
- ML20079J372 + (ML20079J372)
- RBG-13-985, Interim Deficiency Rept DR-79 Re Failure to Follow Weld Procedures on Field Weld.Initially Reported on 821123. Investigation Continuing.Next Rept Expected by 830228 + (ML20079J376)
- ML20079J378 + (ML20079J378)
- 05000416/LER-1982-123-99, /99X-1:on 821102,fire Barrier Penetrations to Cabinets in Control Bldg Broken to Complete Planned Maint Activity.Fire Watch Established.Penetrations Resealed. Limiting Conditions for Operation Cleared + (ML20079J379)
- ML20079J382 + (ML20079J382)
- ML20079J394 + (ML20079J394)
- ML20079J397 + (ML20079J397)
- IR 05000412/1983016 + (ML20079J400)
- ML20079J401 + (ML20079J401)
- ML20079J402 + (ML20079J402)
- ML20079J407 + (ML20079J407)
- ML20079J408 + (ML20079J408)
- ML20079J411 + (ML20079J411)
- ML20079J412 + (ML20079J412)
- ML20079J413 + (ML20079J413)
- ML20079J417 + (ML20079J417)