Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20077A177 + (ML20077A177)
- 05000259/LER-1983-035-01, /01T-0:on 830614,standby Gas Treatment Train a & B Flows Adjusted W/Faulty Instrument Readings.Caused by Component Failure.Instrument Repaired & Calibr + (ML20077A190)
- HL-4740, Advises of Completion of Actions Re NRC Bulletin 93-003, Resolution of Issues Re Reactor Vessel Water Level Instrumentation in Bwrs + (ML20077A191)
- 05000370/LER-1983-026-03, /03L-0:on 830608,while in Mode 1,reactor Coolant Leakage Calculation Revealed Excessive Unidentified RCS Leakage.Caused by Valve 2NM-68 Lifting at Less than Intended Setpoint.Valve Will Be Replaced + (ML20077A198)
- 05000346/LER-1983-030-03, /03L-0:on 830614,during Change in ECCS Coil Assembly 1,floor Plugs Forming Part of Negative Pressure Boundary & Fire Barriers Removed.Caused by Personnel Error. Floor Plugs Reinstalled & New Procedure Written + (ML20077A210)
- 05000263/LER-1994-015, :on 941015,failed Component in Uniterruptible Power Supply Inverter Causes Partial Containment.Caused by Failure of Static Switch Logic Card.Ci Signals Reset & Isolated Sys Returned to Svc as Necessary + (ML20077A211)
- 05000260/LER-1983-034-03, /03L-0:on 830615,during Normal Operation,Hpci Sys Declared Inoperable.Caused by Blown Inverter Fuse F1. Fuse Replaced.Failure Considered Random + (ML20077A215)
- 05000237/LER-1983-050-03, /03L-0:on 830617,snubber 42 on Steam Line a Found to Have Loose Pipe Clamp Which Had Dropped 2 Inches from Normal Position.Probably Caused by Inadequate Tightening of Clamp Bolts During Original Installation + (ML20077A216)
- 05000263/LER-1994-013, :on 941013,spurious 480 Vac Breaker Trip de-energizes 120 Vac Instrument Bus Resulting in Partial Ci. Training Will Be Provided to Operations Personnel on Appropriate Actions + (ML20077A218)
- NRC-94-0105, Forwards Rev 11 to Fermi 2 Radiological Emergency Response Preparedness Plan. Rev Represents Changes Resulting from Updating Fermi 2 Evacuation Time Estimate & Deleting Description of RERP Keycard Classes + (ML20077A220)
- 05000254/LER-1983-025-03, /03L-0:on 830621,maint Dept Observed Valve Yoke Pulled Away from Valve Bonnet & Valve Steam Bent.Caused by Bolts Vibrating Loose.Bent Stem Straightened & Locking Tabs Installed on yoke-to-bonnet Bolting + (ML20077A221)
- 05000328/LER-1983-086-03, /03L-0:on 830610,w/RCS Temp at 558 F & Pressure at 2,215 Psig,Steam Generator Blowdown Containment Isolation Valve 2-FCV-1-32 Failed Closed.Caused by High Temp Environ. Higher Temp Resistant Diaphragm Installed + (ML20077A224)
- ML20077A226 + (ML20077A226)
- ML20077A227 + (ML20077A227)
- 05000446/LER-1994-016, :on 941016,missed Refueling Machine Auxiliary Monorail Hoist Surveillance Due to Personnel Error.Untested Load Indicator Was Replaced W/Appropriate One + (ML20077A238)
- 05000296/LER-1983-036-03, /03L-0:on 830618,two Control Rods Indicated Uncoupled by Rod Overtravel Alarm.Caused by Disconnected Inner Filter,Damaged Spud &/Or Crud Accumulation.Control Rod Electrically Disarmed + (ML20077A241)
- 05000263/LER-1994-014, :on 941013,missed Procedural Step While Switching Power Supply to Reactor Protection Sys to Alternate Source Causes Partial Ci.Ci Signal Reset & Isolation Sys Returned to Svc as Necessary + (ML20077A242)
- 05000286/LER-1994-010, :on 941007,concluded That at Least Two EDGs Inoperable During June 1992 Surveillance Test of Carbon Dioxide Fire Protection Sys.Caused by Inadequate Procedural Guidance.Surveillance Test Revised + (ML20077A246)
- ML20077A248 + (ML20077A248)
- 05000302/LER-1983-018, Updated LER 83-018/01T-1:on 830413,preliminary Repts Received from B&W Indicated 51 of 120 Upper Core Barrel Bolts W/Ultrasonic Flaw Indications.Caused by Intergranular Stress Corrosion Cracking.Bolts Replaced + (ML20077A253)
- JPN-94-059, Forwards Updated Control Room Habitability Rept, Response to NUREG-0737,III.D.3.4,Control Room Habitability for Ja FitzPatrick Nuclear Power Plant + (ML20077A255)
- 05000395/LER-1983-062-03, /03L-0:on 830611 & 12,reactor Bldg Purge Exhaust Radiation Monitor Sample Pump Overload Protector Tripped. Caused by Loose Motor Controller Electrical Connections & Defective Pump Bearing.Bearing Replaced + (ML20077A257)
- 05000370/LER-1983-028-03, /03L-0:on 830608,pressurizer Heater Group 2B Declared Inoperable When Supply Breaker Found Tripped Open. Caused by Damaged Closed Indicator Lamp Socket.Socket Replaced + (ML20077A259)
- ML20077A260 + (ML20077A260)
- 05000265/LER-1983-009-01, /01T-0:on 830630,isolation Valves to Core Spray Discharge Pressure Switches PS-2-1462C & PS-2-1462D for Automatic Depressurization Sys Low Pressure Pump Running Permissive Found Isolated & Sealed + (ML20077A262)
- ML20077A263 + (ML20077A263)
- TXX-4005, Deficiency Rept Re Bolting Matl Used for Cable Tray Clamps. Structural Drawings Specify High Strength Bolting Matls. Bolts Used Were Mild Steel Type.Design Change Issued. Rework Performed as Required + (ML20077A265)
- 05000249/LER-1983-025-03, /03L-0:on 830623 & 24,3D Main Steam Line Radiation Monitor Found Reading Low.Caused by Weak Electrometer Tubes. Monitor Repaired & Calibr + (ML20077A266)
- JAFP-91-0268, Responds to NRC Re Violations Noted in Insp Rept 50-333/91-04 on 910128-0201.Corrective Actions:Perform Fatigue Evaluation & Revise Procedure (MCM-4) + (ML20077A269)
- 05000259/LER-1983-036-01, /01T-0:on 830630,during Cycle 5 Refueling Outage, Seven of 13 two-stage Relief Valves Tested for as-found Set Pressure Initially Failed to Lift within Allowable 1% Tolerance.Cause Being Evaluated + (ML20077A270)
- ML20077A271 + (ML20077A271)
- 05000244/LER-1983-019-03, /03L-0:on 830613,while Changing from Cold to Hot Shutdown,Containment Spray Pumps Found in pull-stop Position at 207 F.Caused by Changes in Tech Spec Interpretation. Pumps Placed in Auto + (ML20077A273)
- 05000298/LER-1994-010-01, :on 940526,closure of Shutdown Cooling Suction Isolation Valves While Warming RHR Sys Due to Leakage Through Minimum Flow Valve.Sr MOV Will Be Checked for torque-in Current During MOV Surveillance + (ML20077A274)
- ML20077A276 + (ML20077A276)
- PLA-1737, Final Deficiency Rept Re Detachment of Ilsco Corp Number 14 Stranded Wire from Screw Clamp Detectors.Initially Reported on 830524.Deficiency Not Reportable Per 10CFR50.55(e) for Unit 2.Item Reportable Per Part 21 for Unit 1 + (ML20077A277)
- ML20077A279 + (ML20077A279)
- ML20077A281 + (ML20077A281)
- ML20077A287 + (ML20077A287)
- ML20077A288 + (ML20077A288)
- 05000325/LER-1994-012, :on 940922,HPCI Declared Inoperable Due to Failure of Lube Oil CW Supply Valve Control Power Fuse. Workers Disciplined Re Importance of Maintaining Questioning Attitude & When Uncertain Not to Proceed + (ML20077A290)
- 05000275/LER-1983-016-03, /03L-0:on 830606,plant Vent Flow Rate Monitor FR-12 Discorerd Deenergized.Caused by Personnel Error. Personnel Cautioned to Research Clearance Requests Prior to Approval + (ML20077A291)
- ML20077A293 + (ML20077A293)
- 05000270/LER-1983-007-03, /03L-0:on 830607,HPI Pump 2F Removed from Svc to Repair Oil Leak at Sight Glass Tap Into Motor Housing.Caused by Component Failure Due to Failure of Threaded Sealant. Pump Motor Repaired & Returned to Svc + (ML20077A294)
- ML20077A298 + (ML20077A298)
- 05000395/LER-1983-059-03, /03L-0:on 830609 & 0702,refueling Water Storage Tank Level Transmitter Failed High.Caused by Intermittent Internal Component Breakdown When Transmitter Temp Exceeds 100 F.Transmitter Will Be Replaced + (ML20077A301)
- 05000413/LER-1994-006-02, :on 941018,TS 3.0.3 Entered Due to Inadequate Work Practices.Opened Access Panels Closed & Work Was Stopped That Involved Assess to Ductwork Until Damper Could Be Secured + (ML20077A304)
- ML20077A308 + (ML20077A308)
- ML20077A309 + (ML20077A309)
- 05000334/LER-1983-019-03, /03L-0:on 830611,while in Hot Standby,Lift Settings on 10 of 15 Main Steam Safety Valves Mfg by Dresser Found Outside Tech Spec Limits.Caused by Valve Lift Setpoint Drift.Settings Readjusted within Tolerance + (ML20077A310)
- ML20077A311 + (ML20077A311)
- 1CAN068311, Monthly Operating Rept for May 1983 + (ML20077A312)