- 05000316/LER-1983-064-03, /03L-0:on 830717,computer P-250 Which Logs Axial Flux Difference Failed.Caused by Personnel Error.Personnel Counseled + (ML20076C319)
- 05000443/LER-1991-007, :on 910615,actuation of Control Room Emergency Air Cleanup & Filtration Subsystems Occurred.Caused by Personnel Error Due to Lack of Attention to Detail.Event Will Be Discuss W/Respective Operating Crews + (ML20076C320)
- ML20076C321 + (ML20076C321)
- ML20076C322 + (ML20076C322)
- ML20076C325 + (ML20076C325)
- ML20076C326 + (ML20076C326)
- ML20076C327 + (ML20076C327)
- ML20076C329 + (ML20076C329)
- ML20076C331 + (ML20076C331)
- AECM-83-0470, Commits to Supply Addl Info Addressing NRC Concerns Re Revised Control Room Inleakage Dose Assessment & Modified Meteorological Assumptions within 6 Months.Discussion of Conservatisms in Revised X/Q Methodology Encl + (ML20076C336)
- 05000373/LER-1983-080-03, /03L-0:on 830707,LPCS Water Leg Pump & Discharge Pressure Low Alarm Tripped.Caused by Frozen Pump W/Outboard Bearing Locked on Pump.Shaft,Bearings,Oil Seals & Mechanical Seal Replaced + (ML20076C340)
- ML20076C347 + (ML20076C347)
- 05000373/LER-1983-075-03, /03L-0:on 830709,while Conducting LOS-PF-Q1, Quarterly Watertight Door Surveilance,Water Tight Door 17 Found Open & Broken.Caused by Broken Shear Pin in Gear Mechanism.Door Repaired + (ML20076C348)
- ML20076C351 + (ML20076C351)
- ML20076C354 + (ML20076C354)
- ML20076C364 + (ML20076C364)
- ML20076C365 + (ML20076C365)
- 05000458/LER-1991-002, :on 910216,ESF Actuation Occurred When Reactor Water Sample Containment Isolation Valve.Caused by Failure of Fuse Pressure High.Replacing Fuse & Reopening Reactor Water Sample Valve + (ML20076C368)
- ML20076C369 + (ML20076C369)
- RBG-15-639, Interim Deficiency Rept R-117 Re Unanalyzed Scenario Which Could Result in Containment Negative Pressure Beyond Design Negative Pressure.Initially Reported on 830517.Util Awaiting Addl Info from Ae.Next Rept by 830930 + (ML20076C370)
- ML20076C373 + (ML20076C373)
- ML20076C374 + (ML20076C374)
- 05000458/LER-1990-023, :on 900523,standby Gas Treatment & Annulus Mixing Sys Declared Inoperable.Caused by Failure of Radiation Monitor Sample Pump.Operation Section Procedure, OSP-012 Revised + (ML20076C375)
- 05000313/LER-1991-007-02, :on 910614,during Insp,Fuse Discovered Inadequate.Caused by Design Inadequacies.Firewatches Posted in Areas of Common Vulnerability & Fuses for Emergency Batteries Replaced + (ML20076C377)
- ML20076C378 + (ML20076C378)
- 05000354/LER-1990-014, :on 900817,discovered Tech Spec Limit for Ultimate Heat Sink Established Unconservatively High. Caused by Design Calculation Error.Design Change Request Initiated + (ML20076C380)
- 05000373/LER-1983-076-03, /03L-0:on 830709,during LIS-R1-01,RCIC Steam Line High Flow Isolation Calibr & Functional Test,Dpis 1E31-N013B Low Setpoint Found Out of Tolerance.Cause Not Determined. Setpoints Recalibr + (ML20076C382)
- ML20076C385 + (ML20076C385)
- ML20076C386 + (ML20076C386)
- ML20076C391 + (ML20076C391)
- 05000315/LER-1983-064-03, /03L-0:on 830707,east Component Cooling Water Miscellaneous Header Isolation Valve CMO-415 Would Not Close Completely from Control Room.Cause Unidentified.Valve Operated Satisfactorily During Retest + (ML20076C392)
- ML20076C394 + (ML20076C394)
- ML20076C400 + (ML20076C400)
- ML20076C401 + (ML20076C401)
- ML20076C403 + (ML20076C403)
- ML20076C409 + (ML20076C409)
- JPN-91-033, Suppl to 900531 Application for Amend to License DPR-59, Consisting of Suppl a to Holtec Rept HI-89399 Re Expansion of Storage Capacity of Spent Fuel Pool.Analysis Indicates That No rack-to-rack Impacts Would Occur W/Reduced Spacing + (ML20076C410)
- 2CAN032001, Response to Request for Additional Information Related to License Amendment Request to Revise the Control Element Assembly Drop Times + (ML20076C413)
- ML20076C415 + (ML20076C415)
- ML20076C419 + (ML20076C419)
- 05000315/LER-1983-065-03, /03L-0:on 830709,fire Barrier Seal Installed in Spray Additive Tank Room When Numerous Other Unsealed Penetrations Noted within Same Room.Caused by Lack of Communication.Fire Watch Posted + (ML20076C420)
- ML20076C423 + (ML20076C423)
- ML20076C424 + (ML20076C424)
- ML20076C427 + (ML20076C427)
- ML20076C428 + (ML20076C428)
- ML20076C429 + (ML20076C429)
- ML20076C434 + (ML20076C434)
- ML20076C440 + (ML20076C440)
- ML20076C451 + (ML20076C451)
- ML20076C452 + (ML20076C452)
- 05000366/LER-1983-066-01, /01T-0:on 830727,while Investigating Problems W/Pressure transmitters,12 Open Links Discovered in MSIV Leakage Control Sys 2E32.Caused by Personnel Error.Links Closed + (ML20076C454)