- 05000302/LER-1983-022-01, /01T-0:on 830516,two Pinhole Leaks Found in Piping on Downstream Side of Two Nuclear Svc HX Discharge Isolation Valves.Caused by Insufficient Surveillance & Design Inadequacy on Inner PVC Liner + (ML20071N903)
- ML20071N904 + (ML20071N904)
- 05000339/LER-1983-037-03, /03L-0:on 830502,containment Particulate (RM-259) & Gaseous (RM-260) Activity Monitors Found Isolated W/ Containment Purge & Exhaust Sys in Operation.Caused by Failure to Reopen Manual Isolation Valve + (ML20071N905)
- ML20071N907 + (ML20071N907)
- 05000338/LER-1983-028-03, /03L-0:on 830507,inside Containment Recirculation Spray Pump 1-RS-P-1B Tripped During Surveillance Testing. Caused by Faulty B Phase Overcurrent Device in Breaker. Replacement Breaker Installed + (ML20071N912)
- 05000255/LER-1983-033-03, /03L-0:on 830428,D Safety Injection Tank T-82D Sampling Indicated Boron Concentration Below Tech Spec Limit.Caused by Minor Leakage Past Loop Check Valve & SIT Check Valve or Fill & Drain Valve + (ML20071N914)
- ML20071N916 + (ML20071N916)
- 05000327/LER-1983-067-01, /01T-0:on 830518,start Bus 1B Failed Due to phase- to-phase Fault.Tech Spec 3.8.1.1 Action Statement a Entered.Diesel Generator Not Operable within 1-h Limit. Caused by Bus Sleeve Insulation Degradation + (ML20071N919)
- ML20071N926 + (ML20071N926)
- ML20071N940 + (ML20071N940)
- ML20071N942 + (ML20071N942)
- ML20071N946 + (ML20071N946)
- ML20071N949 + (ML20071N949)
- ML20071N957 + (ML20071N957)
- 0CAN048307, Submits Supplemental Response to IE Insp Repts 50-313/82-33 & 50-368/82-33.Completion Date for Revised Procedures Re Fire Barriers Changed to 830531.Addl Time Necessary to Incorporate App R Changes + (ML20071N963)
- ML20071N966 + (ML20071N966)
- ML20071N970 + (ML20071N970)
- ML20071N971 + (ML20071N971)
- ML20071N980 + (ML20071N980)
- ML20071N981 + (ML20071N981)
- ML20071N986 + (ML20071N986)
- ML20071N989 + (ML20071N989)
- ML20071N991 + (ML20071N991)
- ML20071N994 + (ML20071N994)
- ML20071P013 + (ML20071P013)
- ML20071P018 + (ML20071P018)
- ML20071P027 + (ML20071P027)
- ML20071P030 + (ML20071P030)
- ML20071P034 + (ML20071P034)
- ML20071P037 + (ML20071P037)
- ML20071P051 + (ML20071P051)
- AECM-82-491, Forwards Info Re Monitoring Trend Analysis Program Per Commitment to Summarize Vibration Monitoring Analysis Program for Deep Draft Pump Reliability Per SER Section 1.10 (13) + (ML20071P052)
- ML20071P056 + (ML20071P056)
- ML20071P062 + (ML20071P062)
- 05000278/LER-1982-020-03, /03L-0:on 821006,during Surveillance Test,Hpci Room Carbon Dioxide Fire Protection Sys Failed to Inject Automatically.Caused by Dirty Contacts on electro-manual Pilot Control Solenoid Valve.Contacts Cleaned + (ML20071P063)
- 05000277/LER-1982-033-03, /03L-0:on 821007,smoke Detector S85 in Torus Room Failed to Calibr to within Specified Limits.Caused by Faulty Smoke Detector,Pyrotronics Model F-5B.Detector Replaced,Unit Calibr & Returned to Svc + (ML20071P065)
- BSEP-83-1581, Ro:Increased Co-60 Activity Found in Two Bottom Sediment Samples Collected 830405 & 06.No Co-60 Found in Surface Water Samples from Intake & Discharge Canals During Apr 1983.No Radiation Hazard or Exposure to Public Observed + (ML20071P075)
- 05000278/LER-1982-018-03, /03L-0:on 820924,torus Narrow Range Level Recorder Indicated Erratically.Investigation Determined Torus Water Level within Tech Spec.Caused by Const Personnel Knocking Instrument Out of Calibr.Personnel Counseled + (ML20071P079)
- ML20071P082 + (ML20071P082)
- 05000321/LER-1983-049-03, /03L-0:on 830505,sanitary Water Supply Valve X42-FO73D Found Open But Not Locked Open.Caused by Personnel Error.Personnel Counseled + (ML20071P087)
- ML20071P089 + (ML20071P089)
- ML20071P090 + (ML20071P090)
- ML20071P098 + (ML20071P098)
- ML20071P099 + (ML20071P099)
- ML20071P111 + (ML20071P111)
- ML20071P113 + (ML20071P113)
- ML20071P115 + (ML20071P115)
- ML20071P116 + (ML20071P116)
- ML20071P117 + (ML20071P117)
- ML20071P118 + (ML20071P118)
- ML20071P122 + (ML20071P122)