- 05000293/LER-1982-057-03, /03L-0:on 821213,during Routine Startup from Outage,Outboard MSIV AO 203-2C Did Not Close within Tech Spec Limit.Caused by Malfunctioning four-way Control Valve. Valve Replaced.Timing Dash Pot Adjusted + (ML20070P399)
- BECO-91-040, Forwards Summary of Compliance W/Reg Guide 1.97,Rev 2 to Assist NRC in Review of Compliance W/Reg Guide 1.97,Rev 3, Per 9100115 & 0405 Ltrs + (ML20070P403)
- 05000327/LER-1991-003, :on 910218,centrifugal Charging Pump Declared Inoperable & Removed from Svc Due to Pump Degradation.Caused by Heavy Wear on Impeller Shoulders in Wear Ring Area.Pump Rotating Element Replaced + (ML20070P412)
- 1CAN039102, Withdraws Relief Request 31 Re Performance of Exercise & Stroke Time Testing for Decay Heat Cooler Bypass Valves CV-1432 & CV-1433 During Each Refueling Outage.Procedures Will Be Revised to Perform Testing During ASME Frequency + (ML20070P415)
- ST-HL-AE-3723, Forwards South Texas Project Unit 1,Cycle 4 Core Operating Limits Rept, Rev 0 + (ML20070P419)
- ML20070P420 + (ML20070P420)
- ML20070P424 + (ML20070P424)
- 05000457/LER-1994-004-07, :on 940406,control Rod K2 Failed to Fully Insert During Trip & Remained Out of Core at Indicated 210 Steps Due to Procedural Deficiency.Corrective Action: Shutdown Margin Calculations Were Performed + (ML20070P426)
- ML20070P429 + (ML20070P429)
- 05000456/LER-1994-007-02, :on 940407,SG Tube Found Degraded Due to Axial Outer Diameter Stress Corrosion Cracking.Corrective Actions: Implemented Programs to Mitigate Corrosive Environment in Tube Support + (ML20070P433)
- ML20070P437 + (ML20070P437)
- ML20070P444 + (ML20070P444)
- 05000317/LER-1982-079, Forwards LER 82-079/03L-0 + (ML20070P459)
- ML20070P466 + (ML20070P466)
- ML20070P472 + (ML20070P472)
- 05000317/LER-1982-079-03, /03L-0:on 821209,due to Loading of Main Turbine Generator & on 821229,during Normal Shutdown Operation, Pressurizer Level Deviated from Program Band.Rcs Temp Swing Not Uncommon During Shutdown Operations + (ML20070P474)
- 05000423/LER-1990-001, :on 910108,inoperable Fire Hose Stations Due to Insufficient Fire Hose Inventory.Cause Unknown for Fuel Bldg Fire Hose Rack & Procedural Inadequacy for Auxiliary Bldg Fuel Racks.Station Restored to Operable Status + (ML20070P477)
- ML20070P481 + (ML20070P481)
- ML20070P484 + (ML20070P484)
- ML20070P489 + (ML20070P489)
- ML20070P492 + (ML20070P492)
- 05000220/LER-1982-020-03, /03L-0:on 821213,while Performing Local Leak Rate Testing,Leakage from Valves 58.1-01 & 58.1-02 Exceeded Tech Specs.Caused by Valve Order.Existing Order Modified W/Check Valve Followed by Gate Valve + (ML20070P497)
- 05000333/LER-1983-001-04, /04T-0:on 821230,number of Fish Impinged During 24 H Period Exceeded 20,000.Caused by Bad Weather Conditions Experienced During Sampling.Sampling Continued Until Fish Count Fell Below 20,000 + (ML20070P504)
- 05000382/LER-1991-002-01, :on 910221,inadvertent Control Room Outside Air Isolation Due to Equipment Malfunction.Beta Radiation Window Light Was Replaced & Returned to Svc + (ML20070P507)
- ML20070P512 + (ML20070P512)
- 05000220/LER-1982-021-03, /03L-0:on 821215,while Performing Local Leak Rate Testing,Leakage from Valves 39-11,39-12,39-13 & 39-14 Exceeded Tech Specs.Caused by Dry Packing Condition Resulting from Current Shutdown.Valves Will Be Repacked + (ML20070P513)
- ML20070P519 + (ML20070P519)
- BECO-91-038, Submits Annual Rept of Property Damage Insurance Coverage, Per 10CFR50.54(w) + (ML20070P542)
- ML20070P552 + (ML20070P552)
- 05000220/LER-1982-022-03, /03L-0:on 821218,while Performing Local Leak Rate Testing,Leakage from Valves 201.2-27 & 201.2-28 Exceeded Tech Specs.Caused by Poor Seating Resulting from Dirt & Corrosion.Valves Will Be Cleaned + (ML20070P553)
- ML20070P562 + (ML20070P562)
- ML20070P563 + (ML20070P563)
- 05000277/LER-1991-007, :on 910221,RHR Mo Inboard Isolation Valve MO-2-10-25B Closed on Isolation Signal.Caused by Specified Blocking Permit Less than Adequate.Permit Writers Directed to Walkdown Permits + (ML20070P573)
- ML20070P581 + (ML20070P581)
- ML20070P591 + (ML20070P591)
- NG-94-1378, Responds to NRC Generic Ltr 89-10,suppl 5, Inaccuracy of MOV Diagnostic Equipment + (ML20070P597)
- 05000220/LER-1982-023-03, /03L-0:on 821218,while Performing Local Leak Rate Testing,Valve 201.2-71 Exceeded Tech Specs.Caused by Poor Seating Resulting from Dirt & Corrosion.Valve Will Be Cleaned Followed by Retest + (ML20070P601)
- BECO-94-054, Provides Response to Request for Addl Info for Relief Requests PRR-17,PRR-18 & PRR-19.Encl B Provides Revised Relief PRR-17.Encl C Provides Informational Drawing Packages for Revised PRR-17,Rev 1,PRR-18 & PRR-19 + (ML20070P604)
- ML20070P606 + (ML20070P606)
- ST-HL-AE-3711, Proposes Alternative Wording for NRC SER on Util Turbine Sys Maint Program,Submitted to Util Via NRC .Changes Cover Insp Invervals for Low Pressure Turbines & Insp of Low Pressure Turbine Rotors + (ML20070P625)
- 05000387/LER-1982-077, Forwards LER 82-077/03L-0 + (ML20070P638)
- 05000387/LER-1982-077-03, /03L-0:on 821217,one HPCI Steam Line Sensor Setpoint Found Out of Allowable Value Range.Caused by Instrument Drift.Revised Setpoints for Instrument Determined & Surveillance Procedure Changed + (ML20070P652)
- AECM-83-020, Final Deficiency Rept PRD-82/37 Re Failure of Qualified Cables to Pass IEEE Flame Test.Initially Reported on 821214. Design Change DCP-82/3196 Initiated.Also Reported Per Part 21 + (ML20070P672)
- 05000416/LER-1982-176, Forwards LER 82-176/99X-0 + (ML20070P673)
- 05000416/LER-1982-176-99, /99X-0:on 821215 & 17,fire Barriers AE-290 & 1H13-4732 Opened to Route Cables Used for Mods to Transient Test Sys.Work Currently in Progress to Reseal Barriers + (ML20070P683)
- ML20070P692 + (ML20070P692)
- 05000317/LER-1982-076, Forwards LER 82-076/03L-0 + (ML20070P699)
- 05000317/LER-1982-076-03, /03L-0:on 821219,during Performance of Routine Test,Containment Air Cooler Fan 12 Would Not Shift to Low Speed or Manually Start in Slow Speed.Caused by Relay Contacts Not Making Proper Contact.Relay Will Be Replaced + (ML20070P705)
- ML20070P707 + (ML20070P707)
- 05000317/LER-1982-081, Forwards LER 82-081/03L-0 + (ML20070P730)
- 05000317/LER-1982-081-03, /03L-0:on 821227,snubber 1-83-53 Found Inoperable. Caused by Low Oil Reservoir Due to Leakage at rod-end Cylinder Seal.Snubber Replaced + (ML20070P737)