.e DUKE power GOMPANY 18.0. ISOX 03115D CitAllIJYFTE, N.C. 2fl242 II AL II. TUGKI;It Terf.pnoxe s so a emen.or.sv (yo.g) <ay<xmg January 25, 1983

..o r.. r Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, D. C. 20555 Attention: Ms. E. G. Adensam, Chief Licensing Branch No. 4 s

Re:

Catawba NJclear Station Docket Nos. 50-413 and 50-414

Dear Mr. Denton:

Mr. R. L. Tedesco's letter of April 27, 1982 transmitted the draft Safety Evaluation Report from the Auxiliary Systems Branch. Attached is Duke Power Company's response to Open Item 20, parts 3 and 4, which was discussed in the ASB draft SER.

Very truly yours, t

FALF$.ToCK -

Hal B. Tucker ROS/php Attachment l

l gal 8301260339 830125 PDR ADOCK 05000413 E

PDR

Mr. Harold R. Denton, Director January 25, 1983 Page 2 cc: Mr. James P. O'Reilly, Regional Administrator U. S. Nuclear Regulatory Commission Region II 101 Marietta Street, Suite 3100 Atlanta, Georgia 30303 Mr. P. K. Van Doorn NRC Resident Inspector Catawba Nuclear Station Mr. Robert Guild, Esq.

Attorney-at-Law P. O. Box 12097 Charleston, South Carolina 29412 Palmetto Alliance 2135h Devine Street Columbia, South Carolina 29205 Mr. Jesse L. Riley Carolina Environmental Study Group 854 Henley Place Charlotte, North Carolina 28207 Mr. Henry A. Presler, Chairman Charlotte-Mecklenburg Environmental Coalition 943 Henley Place Charlotte, North Carolina 28207 e

1

,.m


s

e Response to Draft SER, Open Item 20, Parts 3 & 4 20.

Section 10./.9 - Auxiliary Feedwater System - The applicant has not verified... (3) that adequate suction is available to prevent AFWS pump damage during transfer to the nuclear service water backup water source (Recommendation GL-4 of NUREG-0611); (4) that air binding of AFWS pumps does not occur prior to tran; ferring pump suction supply.

Response

Adequate suction is available to prevent auxiliary feedwater pump damage during suction transfer to nuclear service water. Air binding of the pumps will not occur prior to or during transfer. Calculations were performed to determine worst case pump suction conditions during transfer. These worst case pump suction conditions were reviewed by the pump manufacturer and were found to cause no pump damage and no air binding.

l

{