- LIC-94-0138, Forwards FCS Performance Indicators Rept for May 1994 + (ML20069P967)
- ML20069P972 + (ML20069P972)
- 05000333/LER-1982-050, Forwards LER 82-050/03L-0 + (ML20069P975)
- 05000219/LER-1982-054-03, /03L-0:on 821105,after Completing TIP Trace, Ball Valve on TIP Machine 3 Failed to Close.Caused by Moisture Buildup Around in-shield Limit Switch Operating Arm.Arm Cleaned & Switch Aligned + (ML20069P979)
- ML20069P982 + (ML20069P982)
- 05000382/LER-1990-018-03, :on 901206,discovered That Shutdown Cooling Sys Suction Line Relief Valves Not Demonstrated Operable Since Issuance of OL on 841218.Caused by Overlooking Configuration Since TS Written.Ts Change Will Be Sent + (ML20069P983)
- ML20069P994 + (ML20069P994)
- 05000373/LER-1982-140, Forwards LER 82-140/03L-0 + (ML20069Q000)
- ML20069Q004 + (ML20069Q004)
- 05000265/LER-1982-023-03, /03L-0:on 821104,turbine Stop Valve Could Not Be Reset During HPCI Testing,Preventing Turbine Operation. Caused by Corroded Contacts on Valve Hydraulic Oil Pressure Switch.Switch Replaced.Hpci Switches Cleaned + (ML20069Q016)
- ML20069Q019 + (ML20069Q019)
- 05000333/LER-1982-050-03, /03L-0:on 821109,scram Discharge Vol Rod Block Level Surveillance Test Not Performed within 7 Days of Reactor Startup,Per Tech Spec.Caused by Failure to Enter Frequency Statement in Procedure During Review of Amend 62 + (ML20069Q021)
- ML20069Q023 + (ML20069Q023)
- 05000373/LER-1982-140-03, /03L-0:on 821030,offgas Pretreatment Monitor Became Inoperative.Caused by Loss of Flow Due to Water in Sample Line.Sample Line Drained.Purge Valve Installed to Allow Proper Flow + (ML20069Q031)
- 05000373/LER-1982-139, Forwards LER 82-139/03L-0 + (ML20069Q036)
- ML20069Q038 + (ML20069Q038)
- 05000373/LER-1982-139-03, /03L-0:on 821030,Div 11 Oxygen Channel Was Reading Erratically.Caused by Moisture Buildup in Oxygen Sample Flowmeter.Moisture Removed & Instrumentation Recalibr + (ML20069Q039)
- ML20069Q042 + (ML20069Q042)
- 05000334/LER-1981-078, Forwards Updated LER 81-078/03X-1 + (ML20069Q054)
- 05000282/LER-1982-022, Forwards LER 82-022/03L-0 + (ML20069Q059)
- 05000282/LER-1982-022-03, /03L-0:on 821112,during Power Operation,Control Power Lost to Diesel Cooling Water Pump 22,rendering Pump Inoperable.Caused by Loose Fuse Clip.Clip Repaired & Pump Tested Satisfactorily + (ML20069Q067)
- 05000311/LER-1982-135, Forwards LER 82-135/01T-0.Detailed Event Analysis Encl + (ML20069Q075)
- 05000334/LER-1981-078-03, Discovered Leakage Through Containment Airlock Inner Door Seals.Inner Door Sealing Surfaces & O-rings Wiped Down & Regreased.Design Change Procedure Approved on 820605 + (ML20069Q083)
- 05000317/LER-1982-072, Forwards LER 82-072/04X-0 + (ML20069Q089)
- 05000311/LER-1982-135-01, /01T-0:on 821121,during Routine Surveillance,Small Svc Water Leak Discovered on Cooling Coil of Containment Fan Coil Unit 25.Caused by Silt in Svc Water.Coil Repaired.New Design Coils Will Be Installed During Next Refueling + (ML20069Q096)
- ST-HL-AE-3666, Requests Waiver of Compliance from Requirements of TS 3.3.3.1,Table 3.3-6 on one-time Basis + (ML20069Q097)
- ML20069Q101 + (ML20069Q101)
- ML20069Q106 + (ML20069Q106)
- 05000317/LER-1982-072-04, /04X-0:on 821027,higher than Normal Background Radioactive Ag-110m Levels Found in Oyster Samples Taken from Camp Canoy Location on 821123.Caused by Natural Tendency of Oysters to Concentrate Environ Silver + (ML20069Q107)
- 05000334/LER-1981-077, Forwards Updated LER 81-077/03X-1 + (ML20069Q115)
- ML20069Q131 + (ML20069Q131)
- ST-HL-AE-4797, Forwards Pump Relief Requests RR-13 for Unit 1 & RR-12 & RR-13 for Unit 2 to Use Permanently Installed Instrumentation as Alternate Testing Instrument + (ML20069Q134)
- ML20069Q155 + (ML20069Q155)
- ML20069Q163 + (ML20069Q163)
- ML20069Q169 + (ML20069Q169)
- ML20069Q173 + (ML20069Q173)
- ML20069Q178 + (ML20069Q178)
- 05000324/LER-1994-008-02, :on 940521,dispatcher Switching Evolution Resulted in Loss of Offsite Power.Instructions for Any Planned Switching Activity at Nuclear Power Plant Will Require Dual Verification + (ML20069Q198)
- ML20069Q200 + (ML20069Q200)
- 05000334/LER-1981-077-03, Increased Radiation Levels in Auxiliary Bldg Discovered.Caused by Crack in Welded Pipe Connection Joining Two 1A Degassifier Recovery Hx.Crack Due to Thermal Stress Fatigue + (ML20069Q216)
- ML20069Q218 + (ML20069Q218)
- ML20069Q223 + (ML20069Q223)
- 05000373/LER-1982-143, Forwards LER 82-143/03L-0 + (ML20069Q234)
- ML20069Q242 + (ML20069Q242)
- ML20069Q244 + (ML20069Q244)
- 05000369/LER-1990-033, :on 901206,operations Personnel Unable to Verify Readings from Power Range Detectors to Thermal Power Best Estimate Value,Per Tech Spec 4.3.1.1.(2).Caused by Procedure Deficiencies.Solder Repaired + (ML20069Q247)
- 05000373/LER-1990-013-06, :on 901207,discovered That 8 Valves Left Out of Operating Surveillance LOS-RH-Q2 Re RHR & RHR Svc Water Valve Inservice Test for Operating Conditions 1,2 & 3.Caused by Procedural Deficiency.Procedure Revised + (ML20069Q248)
- 05000369/LER-1990-034, :on 901206,both Trains of Control Area Ventilation Sys Declared Inoperable to Change Out Filters. Cause Not Stated.Personnel Access Door Reclosed + (ML20069Q252)
- 05000254/LER-1990-025, :on 901206,ESF Group II Isolation Occurred Due to Spurious Signal from Low Level Transmitter Lt 1-263-58A. Caused by Formation of Air Pocket in Transmitter Ref Leg. Procedures for Draining Vessel Enhanced + (ML20069Q255)
- 05000313/LER-1990-017-02, :on 901207,inadvertent Automatic Start of DHR Low Pressure Injection Pump Occurred During Testing.Caused by Personnel Error.Event Discussed W/Electrical Maint Personnel + (ML20069Q260)
- ML20069Q261 + (ML20069Q261)